Electrochemically controlled solid-phase microextraction (EC-SPME) based on overoxidized sulfonated polypyrrole

被引:49
作者
Tamer, U [1 ]
Ertas, N
Udum, YA
Sahin, Y
Pekmez, K
Yildiz, A
机构
[1] Gazi Univ, Fac Pharm, Cent Res Lab, TR-06330 Ankara, Turkey
[2] Gazi Univ, Fac Pharm, Dept Analyt Chem, TR-06330 Ankara, Turkey
[3] Anadolu Univ, Dept Analyt Chem, TR-26470 Eskisehir, Turkey
[4] Hacettepe Univ, Dept Analyt Chem, TR-06532 Ankara, Turkey
关键词
electrochemically controlled solid-phase microextraction; nickel; cadmium; overoxidized sulfonated polypyrrole; cation exchange polymer; ETAAS;
D O I
10.1016/j.talanta.2005.03.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the extraction and selective determination of cations is proposed using electro-synthesized overoxidized sulfortated polypyrrole film. The polymer film is used for the selective extraction of trace levels of nickel and cadmium ions by solid-phase microextraction (SPME). The cation uptake and release properties of the overoxidized sulfonated polypyrrole film electrode were examined under both open circuit and controlled potential conditions for prospective applications in electrochemically controlled solid-phase microextraction. Increased extraction efficiency and selectivity toward cations were achieved in high saline content of water. Simple preparation of film coatings on a platinum wire was possible using a constant potential method. Applied positive and negative potentials facilitated the extraction and desorption of cations, respectively. Nickel and cadmium ions were desorbed into sample aliquot and determined by electrothermal atomic absorption spectrometry (ETAAS). The cation uptake and release mechanism is affected both by the cation exchange at the negative sulfonate and carboxylate moiety on the film and the altered solution pH occurring at the counter electrode caused by the applied potential. The method was validated using a standard reference material and tested for the determination of cadmium ion in commercial table salt samples. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 43 条
[1]   Sorption of arsenic, bismuth, mercury, antimony, selenium and tin on dithiocarbamate loaded polyurethane foam as a preconcentration method for their determination in water samples by simultaneous inductively coupled plasma atomic emission spectrometry and electrothermal atomic absorption spectrometry [J].
Arpadjan, S ;
Vuchkova, L ;
Kostadinova, E .
ANALYST, 1997, 122 (03) :243-246
[2]   Ion-exchange voltammetry as a solid-phase microextraction analytical method: Factors influencing the mass transfer to perfluorosulfonated ionomer film-coated electrodes and some of their consequences on the current responses [J].
Bagel, O ;
Degrand, C ;
Limoges, B .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3192-3199
[3]   ORGANIC ELECTROCHEMISTRY IN THE SOLID STATE-OVEROXIDATION OF POLYPYRROLE [J].
BECK, F ;
BRAUN, P ;
OBERST, M .
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1987, 91 (09) :967-974
[4]   Usefulness of the chemical modification and the multi-injection technique approaches in the electrothermal atomic absorption spectrometric determination of silver, arsenic, cadmium, chromium, mercury, nickel and lead in sea-water [J].
Bermejo-Barrera, P ;
Moreda-Pineiro, J ;
Moreda-Pineiro, A ;
Bermejo-Barrera, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (08) :777-786
[5]   Determination of arsenic(V) as a heteropoly acid after its adsorption on a fibrous anion exchanger [J].
Dedkova, VP ;
Shvoeva, OP ;
Savvin, SB .
JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 57 (04) :298-302
[6]   Potential-induced enantioselective uptake of amino acid into molecularly imprinted overoxidized polypyrrole [J].
Deore, B ;
Chen, ZD ;
Nagaoka, T .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :3989-3994
[7]   A POLYMER ELECTRODE WITH VARIABLE CONDUCTIVITY - POLYPYRROLE [J].
DIAZ, AF ;
CASTILLO, JI .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1980, (09) :397-398
[8]   Potentiometric behavior of electrodes based on overoxidized polypyrrole films [J].
Ersöz, A ;
Gavalas, VG ;
Bachas, LG .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (7-8) :786-790
[9]   ELECTROCHEMICAL-BEHAVIOR OF DOPAMINE AND ASCORBIC-ACID AT OVEROXIDIZED POLYPYRROLE(DODECYL SULFATE) FILM-COATED ELECTRODES [J].
GAO, ZQ ;
IVASKA, A .
ANALYTICA CHIMICA ACTA, 1993, 284 (02) :393-404
[10]   THE INFLUENCE OF OVEROXIDATION TREATMENT ON THE PERMEABILITY OF POLYPYRROLE FILMS [J].
GAO, ZQ ;
ZI, MX ;
CHEN, BS .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 373 (1-2) :141-148