Simultaneous determination of clozapine and its N-desmethyl and N-oxide metabolites in plasma by liquid chromatography/electrospray tandem mass spectrometry and its application to plasma level monitoring in schizophrenic patients.

被引:60
作者
Aravagiri, M [1 ]
Marder, SR [1 ]
机构
[1] VA Greater Los Angeles Hlth Care Syst, Psychopharmacol Unit, Los Angeles, CA 90073 USA
关键词
clozapine; norclozapine; clozapine N-oxide; simultaneous determination; LC-MS-MS; electrospray; plasma level monitoring;
D O I
10.1016/S0731-7085(01)00410-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A liquid chromatography tandem mass spectrometry (LC-MS-MS) assay method for the simultaneous determination of clozapine and its N-desmethyl (norclozapine) and N-oxide metabolites in human plasma is described, The compounds were extracted from plasma by a single step liquid-liquid extraction procedure and analyzed using a high performance liquid chromatography electrospray tandem mass spectrometer system. The compounds were eluted isocratically on a C-18 column. ionized using positive ion atmospheric pressure electrospray ionization method by a TurboIonspray source and analyzed using multiple reaction monitoring mode. The ion transitions monitored were m/z 327 --> m/z 270 for clozapine, m/z 313 --> m/z 192 for norclozapine, m/z 343 --> m/z 256 for clozapine-N-oxide and m/z 421 --> m/z 201 for internal standard. The standard curves of clozapine, norclozapine and clozapine-N-oxide were linear over the range of 1 ng/ml to 1000 ng/ml when 0.5 ml of plasma was used for the analysis (r(2) > 0.998). Three pooled plasma samples collected from patients who were treated with clozapine were used as long-term quality control samples to check the validity of spiked standard curve samples made at various times. The intra- and inter-assay variations for the spiked standard curve and quality control samples were less than 14%. These variations for the long-term patient quality control samples were less than 11%. The LC-MS-MS assay for simultaneous determination of clozapine, norclozapine and clozapine-N-oxide reported here is highly specific. sensitive, accurate and rapid. This method is currently being used for the plasma level monitoring of clozapine and its N-desmethyl and N-oxide metabolites in patients treated with clozapine. The plasma levels of clozapine. norclozapine and clozapine-N-oxide varied widely within and among patients. The data revealed that the norclozapine and clozapine N-oxide metabolites were present at about 58% +/- 14% and 17% +/- 6% of clozapine concentrations in plasma. respectively. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:301 / 311
页数:11
相关论文
共 31 条
[21]  
Liu ZC, 1995, J PHARMACOL EXP THER, V275, P1476
[22]  
LOPDAHL M, 1991, THER DRUG MONIT, V13, P69
[23]  
MARDER SR, 1990, PSYCHOPHARMACOL B, V29, P256
[24]   ONLINE FULLY AUTOMATED-DETERMINATION OF CLOZAPINE AND DESMETHYLCLOZAPINE IN HUMAN SERUM BY SOLID-PHASE EXTRACTION ON EXCHANGEABLE CARTRIDGES AND LIQUID-CHROMATOGRAPHY USING A METHANOL BUFFER MOBILE-PHASE ON UNMODIFIED SILICA [J].
OLESEN, OV ;
POULSEN, B .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 622 (01) :39-46
[25]   NONEQUILIBRIUM METHOD FOR RADIOIMMUNOASSAY OF CLOZAPINE IN PRESENCE OF METABOLITES [J].
ROSENTHALER, J ;
NIMMERFALL, F ;
SIGRIST, R ;
MUNZER, H .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1977, 80 (02) :603-609
[26]  
SIMPSON GM, 1978, AM J PSYCHIAT, V135, P99
[27]  
STILLE G, 1971, FARM ED PRAT, V26, P603
[28]  
VANPUTTEN T, 1993, PSYCHOPHARMACOL BULL, V29, P315
[29]  
VOLPICELLI SA, 1993, CLIN CHEM, V39, P1656
[30]   DETERMINATION OF CLOZAPINE AND ITS MAJOR METABOLITES IN HUMAN SERUM USING AUTOMATED SOLID-PHASE EXTRACTION AND SUBSEQUENT ISOCRATIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
WEIGMANN, H ;
HIEMKE, C .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 583 (02) :209-216