Characterization of wastewater toxicity by means of a whole-cell bacterial biosensor, using Pseudomonas putida, in conjunction with chemical analysis

被引:24
作者
Farré, M [1 ]
Barceló, D [1 ]
机构
[1] CSIC, IIQAB, Dept Environm Chem, ES-08034 Barcelona, Spain
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2001年 / 371卷 / 04期
关键词
D O I
10.1007/s002160100925
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new amperometric biosensor based on inhibition of Pseudomonas putida has been developed to assess the acute toxicity of wastewater. This system uses the biological component immobilized on disposable screen-printed electrodes. The responses for a selected group of polar organic standard substances were studied using Pseudomonas putida as biological component. The results have been compared with responses obtained using the same system and Escherichia coli as biological component and with the bioluminescence inhibition of Vibrio fisheri using ToxAlert 100. Different properties, e.g. the standard deviation (SD) of the data, the goodness of fit (W) and the standard deviation (Syx) of the vertical distances of the points from the inhibition curve, the 50% effective concentration (EC50) and the toxicity units (TII50) of the standard substance, were calculated and compared. This biosensor was used to assess the acute toxicity of real wastewater samples collected at different wastewater treatment plants (WWTP). Finally, a sequential solid-phase extraction (SSPE) procedure followed by liquid chromatography-mass spectrometry (LC-MS) was used to determine the polar organic toxic substances present in the wastewater samples.
引用
收藏
页码:467 / 473
页数:7
相关论文
共 28 条
[1]   Toxicity testing with Vibrio fischeri: A comparison between the long term (24 h) and the short term (30 min) bioassay [J].
Backhaus, T ;
Froehner, K ;
Altenburger, R ;
Grimme, LH .
CHEMOSPHERE, 1997, 35 (12) :2925-2938
[2]   DETERMINING CHEMICAL TOXICITY TO AQUATIC SPECIES [J].
BLUM, DJW ;
SPEECE, RE .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1990, 24 (03) :284-293
[3]   Identification of polar toxicants in industrial wastewaters using toxicity-based fractionation with liquid chromatography/mass spectrometry [J].
Castillo, M ;
Barcelo, D .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3769-3776
[4]   Identification of polar, ionic, and highly water soluble organic pollutants in untreated industrial wastewaters [J].
Castillo, M ;
Alonso, MC ;
Riu, J ;
Barcelo, D .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (08) :1300-1306
[5]  
CENTENO MD, 1993, SETAC SP P, P37
[6]  
Evans MR, 1998, PESTIC SCI, V54, P447, DOI 10.1002/(SICI)1096-9063(199812)54:4<447::AID-PS846>3.0.CO
[7]  
2-9
[8]   Toxicity assessment of organic pollution in wastewaters using a bacterial biosensor [J].
Farré, M ;
Pasini, O ;
Alonso, MC ;
Castillo, M ;
Barceló, D .
ANALYTICA CHIMICA ACTA, 2001, 426 (02) :155-165
[9]  
Ferrari B, 1999, ENVIRON TOXICOL CHEM, V18, P1195, DOI [10.1002/etc.5620180618, 10.1897/1551-5028(1999)018&lt
[10]  
1195:EAOSWA&gt