Objectives This study aims to assess the mid- to long-term follow-up of patients after valve embolization at the time of transcatheter aortic valve implantation (TAVI). Background Transcatheter heart valve (THV) embolization is a rare but serious complication during TAVI. Although various techniques have been developed to manage acute complications and reduce periprocedural morbidity/mortality, long-term clinical and hemodynamic consequences after these events are unknown. Methods Patients who developed THV embolization after TAVI were prospectively assessed. Clinical and echocardiographic characteristics were recorded at baseline and after successful TAVI/surgical aortic valve replacement. The THV migration and strut fractures/degeneration were assessed by computed tomography. Results A total of 7 patients had THV embolization, all of which occurred immediately after valve deployment. The embolized THV was repositioned in the aortic arch proximal to the left subclavian artery (n = 2), immediately distal to the left subclavian artery (n = 2), and in the abdominal aorta (n = 3). A second THV was implanted successfully at the same sitting in 4 patients and at the time of a second procedure in 2 patients. Elective conventional aortic valve replacement was performed in 1 patient. Median follow-up was 1,085 days. One patient died during follow-up from an unrelated cause. The remaining 6 survivors were in New York Heart Association functional class I or II at final follow-up. Mid-term computed tomography follow-up (n = 4,591 to 1,548 days) showed that the leaflets of the embolized THV remain open in all phases of the cardiac cycle. There was also no strut fracture or migration of these valves. Conclusions Clinical outcomes remain good when THV embolization is managed effectively. There are no apparent hemodynamic consequences of a second valve placed in the series. These embolized valves remain in a stable position with no evidence of strut fractures at mid-term follow-up. (J Am Coll Cardiol Intv 2011;4:228-34) (C) 2011 by the American College of Cardiology Foundation
引用
收藏
页码:228 / 234
页数:7
相关论文
共 13 条
[1]   Prevention and Management of Transcatheter Balloon-Expandable Aortic Valve Malposition [J].
Al Ali, Abdullah M. ;
Altwegg, Lukas ;
Horlick, Eric M. ;
Feindel, Christopher ;
Thompson, Christopher R. ;
Cheung, Anson ;
Carere, Ronald G. ;
Humphries, Karin ;
Ye, Jian ;
Masson, Jean-Bernard ;
Webb, John G. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (04) :573-578
[2]   Percutaneous implantation of a valve in the descending aorta in lambs [J].
Boudjemline, Y ;
Bonhoeffer, P .
EUROPEAN HEART JOURNAL, 2002, 23 (13) :1045-1049
[3]  
Boudjemline Younes, 2002, Med Sci Monit, V8, pBR113
[4]   Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[5]   Procedural and Mid-Term Results in Patients With Aortic Stenosis Treated With Implantation of 2 (In-Series) CoreValve Prostheses in 1 Procedure [J].
Gerckens, Ulrich ;
Latsios, George ;
Mueller, Ralf ;
Buellesfeld, Lutz ;
John, Daniel ;
Yuecel, Seyrani ;
Sauren, Barthel ;
Felderhof, Thomas ;
Iversen, Stein ;
Grube, Eberhard .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (02) :244-250
[6]   Risk factors for perioperative stroke after thoracic endovascular aortic repair [J].
Gutsche, Jacob T. ;
Cheung, Albert T. ;
McGarvey, Michael L. ;
Moser, William G. ;
Szeto, Wilson ;
Carpenter, Jeffrey P. ;
Fairman, Ronald M. ;
Pochettino, Alberto ;
Bavaria, Joseph E. .
ANNALS OF THORACIC SURGERY, 2007, 84 (04) :1195-1200
[7]  
Kodali SK, 2006, AM J CARDIOL, V98, p48M
[8]   Transcatheter Aortic Valve Implantation Review of the Nature, Management, and Avoidance of Procedural Complications [J].
Masson, Jean-Bernard ;
Kovac, Jan ;
Schuler, Gerhard ;
Ye, Jian ;
Cheung, Anson ;
Kapadia, Samir ;
Tuzcu, Murat E. ;
Kodali, Susheel ;
Leon, Martin B. ;
Webb, John G. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) :811-820
[9]   United States feasibility study of transcatheter insertion of a stented aortic valve by the left ventricular apex [J].
Svensson, Lars G. ;
Dewey, Todd ;
Kapadia, Samir ;
Roselli, Eric E. ;
Stewart, Alan ;
Williams, Matt ;
Anderson, William N. ;
Brown, David ;
Leon, Marty ;
Lytle, Bruce ;
Moses, Jeffrey ;
Mack, Michael ;
Tuzcu, Murat ;
Smith, Craig .
ANNALS OF THORACIC SURGERY, 2008, 86 (01) :46-55
[10]   Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry A European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve [J].
Thomas, Martyn ;
Schymik, Gerhard ;
Walther, Thomas ;
Himbert, Dominique ;
Lefevre, Thierry ;
Treede, Hendrik ;
Eggebrecht, Holger ;
Rubino, Paolo ;
Michev, Iassen ;
Lange, Ruediger ;
Anderson, William N. ;
Wendler, Olaf .
CIRCULATION, 2010, 122 (01) :62-U130