How 'hot' is the pathologically positive sentinel lymph node in breast cancer patients?

被引:18
作者
Bourgeois, P
Nogaret, JM
Veys, I
Hertens, D
Dagnelie, J
Vanhaudenaerde, C
Verdebout, JM
Larsimont, D
机构
[1] Free Univ Brussels, Inst Jules Bordet, Nucl Med Serv, B-1000 Brussels, Belgium
[2] Free Univ Brussels, Inst Jules Bordet, Surg Serv, Brussels, Belgium
[3] Free Univ Brussels, Inst Jules Bordet, Serv Pathol, Brussels, Belgium
[4] Free Univ Brussels, Inst Jules Bordet, Serv Radiol, Brussels, Belgium
关键词
sentinel node; breast; radioactivity; gamma probe; colloids;
D O I
10.1097/00006231-200305000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
When many lymph nodes are found by using lymphoscintigraphic techniques performed to detect the sentinel lymph nodes (SLNs) in breast cancer, it is usual to find that the 'hottest' SLN is not always the node that is pathologically positive (pN+). Various criteria have been proposed to define which radioactive lymph nodes should be removed. In order to determine the frequency with which the hottest SLN 'fails' to be pN+, and to determine which criteria best define the radioactive lymph node to be removed, we reviewed and analysed our cases in which more than one SLN was detected and where there was also at least one pN+ node. From a series of 181 patients, 40 were selected. In 11 of these 40 cases (27.5%), the hottest SLN was not pN+. Radioactivity levels in the pN+SLN of these 11 patients ranged from 2% to 94% of the activity of the hottest SLN. Twenty-one patients (52.5%) showed only micrometastatic (pN1a) disease in one or more SLNs. In four of these patients (19%) the pN1a SLN was not the hottest node. Two of the patients had radioactivity levels in the pN+SLN which were more than 50% of that of the hottest SLN. In another two of these patients (9.5%), radioactivity levels were lower than 50% of that of the hottest node (respectively, 38% and 2%). However, in these two last cases, the first and hottest SLN removed surgically was found, by the pathologist, to consist of six nodes. Macrometastases (dimensions greater than 2 mm) were found in 19 patients. In 12 of these patients, the hottest SLN was macrometastatic although macrometastases and/or micrometastases were found in other 'cooler' SLNs in four of them. In another seven of these patients (36.8%), macrometastases were found in SLNs with radioactive levels lower than 51% of that of the hottest node. One patient (with three SLNs) out of the 40 (2.5%) had one SLN pN+ with less than 10% of that of the hottest. In fact, it contained only one micrometastasis and its activity was equal to 2%. Upon pathological examination, however, the hottest lymph 'node' was found to consist of six nodes. It is concluded that, with four intra-mammary and peritumoural injections of Tc-99m labelled nanosized colloids of Human Serum Albumin (Nanocoll R: Sorin: 74 MBq and 0.05 mg per injection) performed 18-24 h before using a gamma probe to detect the SLNs, the hottest SLN was not the pathologically positive node in 27.5% of patients in our series. By using the activity in the hottest SLN as the reference point, and 10% of this activity as the lower threshold for removing active SLNs, the sensitivity of the technique is 97.5%. ((C) 2003 Lippincott Williams Wilkins).
引用
收藏
页码:513 / 518
页数:6
相关论文
共 13 条
[1]   Lymphatic mapping and sentinel node biopsy in the patient with breast cancer [J].
Albertini, JJ ;
Lyman, GH ;
Cox, C ;
Yeatman, T ;
Balducci, L ;
Ku, NN ;
Shivers, S ;
Berman, C ;
Wells, K ;
Rapaport, D ;
Shons, A ;
Horton, J ;
Greenberg, H ;
Nicosia, S ;
Clark, R ;
Cantor, A ;
Reintgen, DS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (22) :1818-1822
[2]  
Bass SS, 1999, AM SURGEON, V65, P857
[3]   Sentinel lymph node biopsy in breast cancer: Guidelines and pitfalls of lymphoscintigraphy and gamma probe detection [J].
Borgstein, P ;
Pijpers, R ;
Comans, EF ;
van Diest, PJ ;
Boom, RP ;
Meijer, S .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1998, 186 (03) :275-283
[4]   State-of-the-art approaches to sentinel node biopsy for breast cancer: Study design, patient selection, technique, and quality control at Memorial Sloan-Kettering Cancer Center [J].
Cody, HS ;
Borgen, PI .
SURGICAL ONCOLOGY-OXFORD, 1999, 8 (02) :85-91
[5]   The details of successful sentinel lymph node staging for breast cancer [J].
Edwards, MJ ;
Whitworth, P ;
Tafra, L ;
McMasters, KM .
AMERICAN JOURNAL OF SURGERY, 2000, 180 (04) :257-261
[6]  
Gulec SA, 1998, J NUCL MED, V39, P1388
[7]   Practical guidelines for optimal gamma probe detection of sentinel lymph nodes in breast cancer: Results of a multi-institutional study [J].
Martin, RCG ;
Edwards, MJ ;
Wong, SL ;
Tuttle, TM ;
Carlson, DJ ;
Brown, CM ;
Noyes, RD ;
Glaser, RL ;
Vennekotter, DJ ;
Turk, PS ;
Tate, PS ;
Sardi, A ;
Cerrito, PB ;
McMasters, KM .
SURGERY, 2000, 128 (02) :139-144
[8]   Unfiltered sulfur colloid and sentinel node biopsy for breast cancer: Technical and kinetic considerations [J].
Moffat, FL ;
Gulec, SA ;
Sittler, SY ;
Serafini, AN ;
Sfakianakis, GN ;
Boggs, JE ;
Franceschi, D ;
Pruett, CS ;
Pop, R ;
Gurkok, C ;
Livingstone, AS ;
Krag, DN .
ANNALS OF SURGICAL ONCOLOGY, 1999, 6 (08) :746-755
[9]   Sentinel lymph node biopsy in breast cancer: Initial experience at Memorial Sloan-Kettering Cancer Center [J].
O'Hea, BJ ;
Hill, ADK ;
El-Shirbiny, AM ;
Yeh, SDJ ;
Rosen, PP ;
Coit, DG ;
Borgen, PI ;
Cody, HS .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1998, 186 (04) :423-427
[10]  
Pendas S, 1999, AM SURGEON, V65, P500