Design and control of a powered transfemoral prosthesis

被引:463
作者
Sup, Frank [1 ]
Bohara, Amit [1 ]
Goldfarb, Michael [1 ]
机构
[1] Vanderbilt Univ, Dept Mech Engn, Nashville, TN 37235 USA
关键词
medical robots and systems; powered prosthesis; impedance control; gait model;
D O I
10.1177/0278364907084588
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
The paper describes the design and control of a transfemoral prosthesis with powered knee and ankle joints. The initial prototype is a pneumatically actuated powered-tethered device, which is intended to serve as a laboratory test bed for a subsequent self-powered version. The prosthesis design is described, including its kinematic optimization and the design of a three-axis socket load cell that measures the forces and moments of interaction between the socket and prosthesis. A gait controller is proposed based on the use of passive impedance functions that coordinates the motion of the prosthesis with the user during level walking. The control approach is implemented on the prosthesis prototype and experimental results are shown that demonstrate the promise of the active prosthesis and control approach in restoring fully powered level walking to the user.
引用
收藏
页码:263 / 273
页数:11
相关论文
共 32 条
  • [21] Comparison of mechanical energy expenditure of joint moments and muscle forces during human locomotion
    Prilutsky, BI
    Petrova, LN
    Raitsin, LM
    [J]. JOURNAL OF BIOMECHANICS, 1996, 29 (04) : 405 - 415
  • [22] Riener R., 1999, Proceedings of the First Joint BMES/EMBS Conference. 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Society (Cat. No.99CH37015), DOI 10.1109/IEMBS.1999.802608
  • [23] Stair ascent and descent at different inclinations
    Riener, R
    Rabuffetti, M
    Frigo, C
    [J]. GAIT & POSTURE, 2002, 15 (01) : 32 - 44
  • [24] Design, control, and energetic characterization of a solenoid-injected monopropellant-powered actuator
    Shields, Bobby L.
    Fite, Kevin B.
    Goldfarb, Michael
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2006, 11 (04) : 477 - 487
  • [25] STANCE PHASE-CONTROL OF ABOVE-KNEE PROSTHESES - KNEE CONTROL VERSUS SACH FOOT DESIGN
    STEIN, JL
    FLOWERS, WC
    [J]. JOURNAL OF BIOMECHANICS, 1987, 20 (01) : 19 - 28
  • [26] STEIN JL, 1983, THESIS MIT CAMBRIDGE
  • [27] SUP F, 2007, 2007 IEEE INT C ROB
  • [28] ENERGY COST OF WALKING OF AMPUTEES - INFLUENCE OF LEVEL OF AMPUTATION
    WATERS, RL
    PERRY, J
    ANTONELLI, D
    HISLOP, H
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (01) : 42 - 46
  • [29] BIOMECHANICS OF BELOW-KNEE AMPUTEE GAIT
    WINTER, DA
    SIENKO, SE
    [J]. JOURNAL OF BIOMECHANICS, 1988, 21 (05) : 361 - 367
  • [30] Winter DA., 1991, WATERLOO BIOMECHANIC