Pulmonary embolism: Comprehensive evaluation with MR ventilation and perfusion scanning with hyperpolarized helium-3, arterial Spin tagging, and contrast-enhanced MRA

被引:17
作者
Altes, TA
Mai, VM
Munger, TM
Brookeman, JR
Hagspiel, KD
机构
[1] Univ Virginia, Hlth Sci Ctr, Dept Radiol, Charlottesville, VA 22908 USA
[2] Evanston NW Healthcare, Dept Radiol, Evanston, IL USA
[3] Northwestern Univ, Sch Med, Evanston, IL USA
关键词
D O I
10.1097/01.RVI.0000162416.64412.FC
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: Development of a comprehensive magnetic resonance (MR) examination consisting of MR angiography (MRA) and MR ventilation and perfusion (MR V/Q) scan for the detection of pulmonary emboli (PE) and assessment of the technique in a rabbit model. MATERIALS AND METHODS: Reversible PE was induced by inflating a non-detachable silicon balloon in the left pulmonary artery of five New Zealand White rabbits. MR V/Q scans were obtained prior to, during, and after balloon deflation. MRA was performed during balloon inflation. MR ventilation imaging was performed after the inhalation of hyperpolarized helium-3. MR perfusion imaging was performed with Flow-sensitive Alternating Inversion Recovery with an Extra Radiofrequency pulse technique (FAIRER). High-resolution contrast-enhanced MR pulmonary angiography was used to confirm the occlusion of the pulmonary artery. All imaging was performed on a 1.5-T whole body scanner with broadband capabilities. RESULTS: High-resolution ventilation images of the lungs were obtained. No ventilation defects were detected before, during, or after resolution of simulated PE. FAIRER imaging allowed visualization of pulmonary perfusion. No perfusion defects were detected prior to balloon inflation. During balloon inflation (PE), there was decreased perfusion in the left lower lobe. After reversal of the PE, there was improved perfusion to the left lower lobe. In analogy to nuclear medicine techniques, acute PE produced a mismatched defect in the MR V/Q scan. MRA verified the occlusive filling defect in the left pulmonary artery. CONCLUSION: High-resolution MRA and MR V/Q imaging of the lung is feasible and allows comprehensive assessment of pulmonary embolism in one imaging session.
引用
收藏
页码:999 / 1005
页数:7
相关论文
共 37 条
[11]  
HAGSPIEL KD, 1999, EUR RADIOL, V9, pB20
[12]  
KEILHOLZ S, 2002, 10 ANN SCI M INT SOC
[13]   Comparison of first-pass Gd-DOTA and FAIRER MR perfusion imaging in a rabbit model of pulmonary embolism [J].
Keilholz, SD ;
Mai, VM ;
Berr, SS ;
Fujiwara, N ;
Hagspiel, KD .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) :168-171
[14]   Gravity-dependent perfusion of the lung demonstrated with the FAIRER arterial spin tagging method [J].
Keilholz, SD ;
Knight-Scott, J ;
Christopher, JM ;
Mai, VM ;
Berr, SS .
MAGNETIC RESONANCE IMAGING, 2001, 19 (07) :929-935
[15]   Pulmonary ventilation and perfusion scanning using hyperpolarized helium-3 MRI and arterial spin tagging in healthy normal subjects and in pulmonary embolism and orthotopic lung transplant patients [J].
Lipson, DA ;
Roberts, DA ;
Hansen-Flaschen, J ;
Gentile, TR ;
Jones, G ;
Thompson, A ;
Dimitrov, IE ;
Palevsky, HI ;
Leigh, JS ;
Schnall, M ;
Rizi, RR .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1073-1076
[16]  
Mai VM, 1999, JMRI-J MAGN RESON IM, V9, P483, DOI 10.1002/(SICI)1522-2586(199903)9:3<483::AID-JMRI18>3.0.CO
[17]  
2-#
[18]   MR ventilation-perfusion imaging of human lung using oxygen-enhanced and arterial spin labeling techniques [J].
Mai, VM ;
Bankier, AA ;
Prasad, PV ;
Li, W ;
Storey, P ;
Edelman, RR ;
Chen, Q .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) :574-579
[19]  
Mai VM, 2000, MAGN RESON MED, V43, P793, DOI 10.1002/1522-2594(200006)43:6<793::AID-MRM3>3.0.CO
[20]  
2-E