Experimental results with endovascular irradiation via a radioactive stent

被引:32
作者
Carter, AJ [1 ]
Laird, JR [1 ]
机构
[1] WASHINGTON HOSP CTR,WASHINGTON,DC 20010
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1996年 / 36卷 / 04期
关键词
stents; restenosis; radiation;
D O I
10.1016/S0360-3016(96)00410-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The objective of this article is to describe the methods used to manufacture a radioactive stent and to review the experimental data on this therapy designed to improve arterial patency rates after stent placement. Materials and Methods: Surface activation in a cyclotron and io implantation techniques are used to render commercially available vascular stents radioactive. beta-Particle-emitting stents, most commonly P-32, were employed because of their short half-life (14.3 days) and limited range of tissue penetration (3-4 mm), The function and vascular response to these P-32 radioactive stents with varying activities (range 0.14-23 mu Ci) was evaluated in several animal models of arterial injury and restenosis. Results: In porcine iliac arteries, beta-particle-emitting stents with an initial activity of 0.14 mu Ci reduced neointimal formation 37% at 28 days after implant, On histology, the neointima consisted of smooth muscle cells and a proteoglycan-rich matrix, Scanning electron microscopy demonstrated complete endothelialization of the stent, beta-Particle-emitting stents with an initial activity of 3-23 mu Ci inhibited neointimal smooth muscle cell proliferation at 28 days in a porcine coronary restenosis model, The neointima within these high-activity stents consisted of fibrin, erythrocytes, and only rare smooth muscle cells, Studies with 1-year follow-up after implantation of a radioactive stent with a composition of gamma- and beta-particle-emitting radionuclides Co-55,Co-56,Co-57, Mg-52, and Fe-55 and an initial activity of 17.5 mu Ci demonstrated almost complete inhibition of neointimal proliferation in a rabbit model. Conclusion: Endovascular irradiation delivered via a radioactive stent reduces neointimal formation and improves luminal patency without increasing the risk for stent thrombosis in experimental models of restenosis. The optimal radiation dose is unknown, At stent activities >3 mu Ci of P-32, the inhibition of neointimal formation is due to direct radiation affects on proliferating smooth muscle cells, At ultra-low activities (0.14 mu Ci), beta-particle irradiation reduces neointimal formation possibly by impairing cell proliferation or migration, This novel therapy may have a significant impact on preventing stent restenosis, and requires further investigation. Published 1996 by Elsevier Science Inc.
引用
收藏
页码:797 / 803
页数:7
相关论文
共 35 条
  • [31] INTRACORONARY RADIATION BEFORE STENT IMPLANTATION INHIBITS NEOINTIMA FORMATION IN STENTED PORCINE CORONARY-ARTERIES
    WAKSMAN, R
    ROBINSON, KA
    CROCKER, IR
    GRAVANIS, MB
    PALMER, SJ
    WANG, C
    CIPOLLA, GD
    KING, SB
    [J]. CIRCULATION, 1995, 92 (06) : 1383 - 1386
  • [32] INTRACORONARY LOW-DOSE BETA-IRRADIATION INHIBITS NEOINTIMA FORMATION AFTER CORONARY-ARTERY BALLOON INJURY IN THE SWINE RESTENOSIS MODEL
    WAKSMAN, R
    ROBINSON, KA
    CROCKER, IR
    WANG, C
    GRAVANIS, MB
    CIPOLLA, GD
    HILLSTEAD, RA
    KING, SB
    [J]. CIRCULATION, 1995, 92 (10) : 3025 - 3031
  • [33] ENDOVASCULAR LOW-DOSE IRRADIATION INHIBITS NEOINTIMA FORMATION AFTER CORONARY-ARTERY BALLOON INJURY IN SWINE - A POSSIBLE ROLE FOR RADIATION-THERAPY IN RESTENOSIS PREVENTION
    WAKSMAN, R
    ROBINSON, KA
    CROCKER, IR
    GRAVANIS, MB
    CIPOLLA, GD
    KING, SB
    [J]. CIRCULATION, 1995, 91 (05) : 1533 - 1539
  • [34] INTRACORONARY IRRADIATION MARKEDLY REDUCES NEOINTIMAL PROLIFERATION AFTER BALLOON ANGIOPLASTY IN SWINE - PERSISTENT BENEFIT AT 6-MONTH FOLLOW-UP
    WIEDERMANN, JG
    MARBOE, C
    AMOLS, H
    SCHWARTZ, A
    WEINBERGER, J
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (06) : 1451 - 1456
  • [35] INTRACORONARY IRRADIATION MARKEDLY REDUCES RESTENOSIS AFTER BALLOON ANGIOPLASTY IN A PORCINE MODEL
    WIEDERMANN, JG
    MARBOE, C
    AMOLS, H
    SCHWARTZ, A
    WEINBERGER, J
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (06) : 1491 - 1498