摘要
Chemistry-related procedures often involve a substantial investment of manual work. Automated procedures have been developed to reduce the burden of sample processing and analysis. Here, we demonstrate an automated system for sequential sample processing and delivery to a mass spectrometer. This new platform referred to as RAMSAY-2 incorporates two robotic arms. The arms are guided by several inexpensive, open-source, electronic modules. RAMSAY-2 performs various operations on the samples. Two robotic arms work synchronously to process multiple samples. The system recognizes the delivered samples, aliquots solutions (e.g., substrates of biochemical reactions, diluents), incubates the samples with the reagents, delivers the processed samples to the ion source of the mass spectrometer, and initiates data acquisition. The increased efficiency and versatility are due to implementation of two arms, several microfluidic pumps, fast servos, and the modular design of the control unit. RAMSAY-2 handles multiple sample processing workflows encoded in radio frequency identification tags attached to the samples and can easily be reprogrammed according to the specific requirements of sample processing before mass spectrometric detection. As an example, we demonstrate that RAMSAY-2 can autonomously collect data to evaluate enzymatic activities in enzyme samples supplied by the user. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:608 / 616
页数:9
相关论文
共 38 条
[1]  
ALPERT NL, 1969, CLIN CHEM, V15, P1198
[2]   Mass Spectrometry in the Clinical Laboratory: How Have We Done, and Where Do We Need to Be? [J].
Annesley, Thomas ;
Hsing, Ann ;
Majzoub, Joseph ;
Wu, Alan ;
Rockwood, Alan ;
Mason, Donald .
CLINICAL CHEMISTRY, 2009, 55 (06) :1236-1239
[3]  
Armbruster David A, 2014, Clin Biochem Rev, V35, P143
[4]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[5]   Robotic plasma probe ionization mass spectrometry (RoPPI-MS) of non-planar surfaces [J].
Bennett, Rachel V. ;
Morzan, Ezequiel M. ;
Huckaby, Jacob O. ;
Monge, Maria Eugenia ;
Christensen, Henrick I. ;
Fernandez, Facundo M. .
ANALYST, 2014, 139 (11) :2658-2662
[6]   Lab automation: tales along the road to automation [J].
Blow, Nathan .
NATURE METHODS, 2008, 5 (01) :109-111
[7]   Combinatorial chemistry [J].
Borman, S .
CHEMICAL & ENGINEERING NEWS, 1998, 76 (14) :47-+
[8]  
Bruker Website, VERS SAMPL CHANG
[9]  
Butler D, 2016, NATURE, V530, P399, DOI 10.1038/530398a
[10]   Mass spectrometry in the clinical laboratory [J].
Chace, DH .
CHEMICAL REVIEWS, 2001, 101 (02) :445-477