Transfer and evaluation of an automated, low-cost real-time reverse transcription-PCR test for diagnosis and monitoring of human immunodeficiency virus type 1 infection in a west African resource-limited setting

被引:193
作者
Rouet, F
Ekouevi, DK
Chaix, ML
Burgard, M
Inwoley, A
Tony, TD
Danel, C
Anglaret, X
Leroy, V
Msellati, P
Dabis, F
Rouzioux, C
机构
[1] SIDA, Ctr Diagnost & Rech, Abidjan, Cote Ivoire
[2] ANRS, Ditrame Plus Program 1201 1202, Abidjan, Cote Ivoire
[3] Univ Paris 05, Virol Lab, EA 3620, CHU Necker Enfants Malad, Paris, France
[4] ANRS 1220 Primo Ci Cohort, Abidjan, Cote Ivoire
[5] ANRS 1269 Trivacan Trial, Abidjan, Cote Ivoire
[6] Univ Victor Segalen, INSERM, U593, ISPED, Bordeaux, France
[7] ANRS 1224 1278 Pediat Program, Abidjan, Cote Ivoire
关键词
D O I
10.1128/JCM.43.6.2709-2717.2005
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
There is an urgent need for low-cost human immunodeficiency virus type 1 (HIV-1) viral load (VL) monitoring technologies in resource-limited settings. An automated TaqMan real-time reverse transcription-PCR (RT-PCR) assay was transferred to the laboratory of the Centre de Diagnostic et de Recherches sur le SIDA, Abidjan, Cote d'Ivoire, and assessed for HIV-1 RNA VL testing in 806 plasma samples collected within four ANRS research programs. The detection threshold and reproducibility of the assay were first determined. The quantitative results obtained with this assay were compared with two commercial HIV-1 RNA kits (the Versant version 3.0 and Monitor version 1.5 assays) in specimens harboring mainly the circulating recombinant form 02 strain (CRF02). The clinical evaluation of this test was done in different situations including the early diagnosis of pediatric infection and the monitoring of antiretroviral-treated patients. The quantification limit of our method was 300 copies/ml. The HIV-1 RNA values obtained by real-time PCR assay were highly correlated with those obtained by the Versant kit (r = 0.901; P < 0.001) and the Monitor test (r = 0.856; P < 0.001) and homogeneously distributed according to HIV-1 genotypes. For the early diagnosis of pediatric HIV-1 infection, the sensitivity and specificity of the real-time PCR assay were both 100% (95% confidence intervals of 93.7 to 100.0 and 98.3 to 100.0, respectively), compared to the Versant results. Following initiation of antiretroviral treatment, the kinetics of HIV-1 RNA levels were very comparable, with a similar proportion of adults and children below the detection limit during follow-up with our technique and the Versant assay. The TaqMan real-time PCR ($12 per test) is now routinely used to monitor HIV-1 infection in our laboratory. This technology should be further evaluated in limited-resource countries where strains other than CRF02 are prevalent.
引用
收藏
页码:2709 / 2717
页数:9
相关论文
共 44 条
  • [1] COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1995, 346 (8982): : 1085 - 1087
  • [2] Field evaluation of an improved assay using a heat-dissociated p24 antigen for adults mainly infected with HIV-1CRF02_AG strains in Cote d'Ivoire, West Africa
    Bonard, D
    Rouet, F
    Toni, TA
    Minga, A
    Huet, C
    Ekouévi, DK
    Dabis, F
    Salamon, R
    Rouzioux, C
    [J]. JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2003, 34 (03) : 267 - 273
  • [3] A new quantitative HIV load assay based on plasma virion reverse transcriptase activity for the different types, groups and subtypes
    Braun, J
    Plantier, JC
    Hellot, MF
    Tuaillon, E
    Gueudin, M
    Damond, F
    Malmsten, A
    Corrigan, GE
    Simon, F
    [J]. AIDS, 2003, 17 (03) : 331 - 336
  • [4] Calibrated real-time PCR assay for quantitation of human herpesvirus 8 DNA in biological fluids
    Broccolo, F
    Locatelli, G
    Sarmati, L
    Piergiovanni, S
    Veglia, F
    Andreoni, M
    Buttò, S
    Ensoli, B
    Lusso, P
    Malnati, MS
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (12) : 4652 - 4658
  • [5] Monitoring of human immunodeficiency virus infection in resource-constrained countries
    Crowe, S
    Turnbull, S
    Oelrichs, R
    Dunne, A
    [J]. CLINICAL INFECTIOUS DISEASES, 2003, 37 : S25 - S35
  • [6] HIV-1/AIDS and maternal and child health in Africa
    Dabis, F
    Ekpini, ER
    [J]. LANCET, 2002, 359 (9323) : 2097 - 2104
  • [7] Plasma RNA viral load in human immunodeficiency virus type 2 subtype A and subtype B infections
    Damond, F
    Gueudin, M
    Pueyo, S
    Farfara, I
    Robertson, DL
    Descamps, D
    Chène, G
    Matheron, S
    Campa, P
    Brun-Vézinet, F
    Simon, F
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (10) : 3654 - 3659
  • [8] Quantitation of HTLV-I proviral load by a TaqMan real-time PCR assay
    Dehée, A
    Césaire, R
    Désiré, N
    Lézin, A
    Bourdonné, O
    Béra, O
    Plumelle, Y
    Smadja, D
    Nicolas, JC
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2002, 102 (1-2) : 37 - 51
  • [9] HIV-1 RNA detection in plasma for the diagnosis of infection in neonates
    Delamare, C
    Burgard, M
    Mayaux, MJ
    Blanche, S
    Doussin, A
    Ivanoff, S
    Chaix, ML
    Khan, C
    Rouzioux, C
    Akapko
    Allemon
    Allisy
    Armengaud
    Aufrant
    Babinet
    BaderMeunier
    Balde
    Baruchel
    Benichou
    Bensadoun
    Berterottiere
    Blanchard
    Boddaert
    Bompard
    Botto
    Boulley
    Braive
    Brault
    Broyart
    Brunner
    Cacault
    Carlus
    Chalvon
    Ciraru
    Clemencet
    Cohen
    ColinGorski
    Crumiere
    Dallot
    Dandine
    DeCrepy
    DeGennes
    Deberdt
    Debons
    Debre
    Denavit
    Devidas
    Donadieu
    Dubois
    Dumontel
    [J]. JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES AND HUMAN RETROVIROLOGY, 1997, 15 (02): : 121 - 125
  • [10] Quantification of human immunodeficiency virus type 1 proviral load by a TaqMan real-time PCR assay
    Désiré, N
    Dehée, A
    Schneider, V
    Jacomet, C
    Goujon, C
    Girard, PM
    Rozenbaum, W
    Nicolas, JC
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (04) : 1303 - 1310