Morphometric analysis of human bone biopsies:: A quantitative structural comparison of histological sections and micro-computed tomography

被引:507
作者
Müller, R
Van Campenhout, H
Van Damme, B
Van Der Perre, G
Dequeker, J
Hildebrand, T
Rüegsegger, P
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Orthopaed Biomech Lab, Boston, MA 02215 USA
[2] Div Biomech & Engn Design, Leuven, Belgium
[3] Div Histochem & Cytochem, Leuven, Belgium
[4] Arthritis & Metab Bone Dis Res Unit, Leuven, Belgium
[5] Swiss Fed Inst Technol, Inst Biomed Engn, Zurich, Switzerland
[6] Univ Zurich, Zurich, Switzerland
关键词
histologic section; micro-computed tomography (mu CT; micro-CT); quantitative bone morphometry; bone architecture; trabecular bone; iliac crest;
D O I
10.1016/S8756-3282(98)00068-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
As a part of the European Union BIOMED I study "Assessment of Bone Quality in Osteoporosis," the trabecular structure of transiliac bone biopsies was assessed by conventional histomorphometry and by three-dimensional micro-computed tomography (mu CT). Sixty-three cylindrical human transiliac bone specimens were obtained post mortem from 27 women and 36 men (age 23-92 years) and evaluated morphometrically in this study, For the conventional histomorphometric analysis, a pair of four undecalcified sections were prepared from two regions in the mediolateral plane of the bone cores. The sections were stained with the von Kossa technique to obtain high-contrast two-dimensional images. Prior to the histologic sectioning the samples were measured with a desktop mu CT, providing a 14 mu m nominal resolution. The morphometric parameters computed by both methods in two or three dimensions, respectively, were bone volume density (BV/TV), bone surface density (BS/TV), trabecular thickness (Tb,Th), and trabecular separation (Tb,Sp), Results showed highly significant (p < 0.0001) correlations between conventional histology and mu CT for BV/TV (r = 0,93), BS/TV (r = 0.91), Tb.Th (r = 0.84), and Tb.Sp (r = 0,91), The mean percentage differences between histology and I.ECT ranged from 2.5% (BV/TV) to 6.1% (Tb,Th), The high correlations and the low differences in terms of absolute numbers between conventional histomorphometric and micro-tomographic analysis are very promising for the use of micro-tomographic imaging. mu CT is a nondestructive, fast, and very precise procedure that allows the measurement of cancellous and compact bone in unprocessed biopsies or small bones, as well as a fully automatic determination of three-dimensional morphometric indices. (Bone 23:59-66; 1998) (C) 1998 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 29 条
[21]   Analysis of mechanical properties of cancellous bone under conditions of simulated bone atrophy [J].
Muller, R ;
Ruegsegger, P .
JOURNAL OF BIOMECHANICS, 1996, 29 (08) :1053-1060
[22]  
MULLER R, 1994, BONE MINER, V25, pS8
[23]   A DIRECT METHOD FOR FAST 3-DIMENSIONAL SERIAL RECONSTRUCTION [J].
ODGAARD, A ;
ANDERSEN, K ;
MELSEN, F ;
GUNDERSEN, HJG .
JOURNAL OF MICROSCOPY, 1990, 159 :335-342
[24]   RELATIONSHIPS BETWEEN SURFACE, VOLUME, AND THICKNESS OF ILIAC TRABECULAR BONE IN AGING AND IN OSTEOPOROSIS - IMPLICATIONS FOR THE MICROANATOMIC AND CELLULAR MECHANISMS OF BONE LOSS [J].
PARFITT, AM ;
MATHEWS, CHE ;
VILLANUEVA, AR ;
KLEEREKOPER, M ;
FRAME, B ;
RAO, DS .
JOURNAL OF CLINICAL INVESTIGATION, 1983, 72 (04) :1396-1409
[25]   A microtomographic system for the nondestructive evaluation of bone architecture [J].
Ruegsegger, P ;
Koller, B ;
Muller, R .
CALCIFIED TISSUE INTERNATIONAL, 1996, 58 (01) :24-29
[26]  
SCHENK RK, 1980, HDB INNEREN MED, V6, P437
[27]   ON WOLFF LAW OF TRABECULAR ARCHITECTURE [J].
TURNER, CH .
JOURNAL OF BIOMECHANICS, 1992, 25 (01) :1-9
[28]  
Vogel M., 1989, NEUERE ERGEBNISSE OS, V4, P449
[29]   PROPERTIES AND AN ANISOTROPIC MODEL OF CANCELLOUS BONE FROM THE PROXIMAL TIBIAL EPIPHYSIS [J].
WILLIAMS, JL ;
LEWIS, JL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (01) :50-56