Analytical intercomparison between flow injection-chemiluminescence and flow injection-spectrophotometry for the determination of picomolar concentrations of iron in seawater

被引:46
作者
Bowie, AR [1 ]
Sedwick, PN
Worsfold, PJ
机构
[1] Univ Tasmania, Sch Chem, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
[2] Univ Tasmania, Antarctic Climate & Ecosyst Cooperat Res Ctr, Hobart, Tas 7001, Australia
[3] Bermuda Biol Stn Res, St Georges GEO1, Bermuda
[4] Univ Tasmania, Inst Antarctic & So Ocean Studies, Hobart, Tas 7001, Australia
[5] Univ Plymouth, Sch Earth Ocean & Environm Sci, Plymouth PL4 8AA, Devon, England
[6] Univ Plymouth, Plymouth Environm Res Ctr, Plymouth PL4 8AA, Devon, England
来源
LIMNOLOGY AND OCEANOGRAPHY-METHODS | 2004年 / 2卷
基金
澳大利亚研究理事会;
关键词
D O I
10.4319/lom.2004.2.42
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
A lab- and ship-based analytical intercomparison of two flow injection methods for the determination of iron in seawater was conducted, using three different sets of seawater samples collected from the Southern Ocean and South Atlantic. In one exercise, iron was determined in three different size-fractions (< 0.03 μm, < 0.4 mum, and unfiltered) in an effort to better characterize the operational nature of each analytical technique with respect to filter size. Measured Fe concentrations were in the range 0.19 to 1.19 nM using flow injection with luminol chemiluminescence detection (FI-CL), and 0.07 to 1.54 nM using flow injection with catalytic spectrophotometric detection with N, N-dimethyl-p-phenylenediamine dihydrochloride (FI-DPD). The arithmetic mean for the FI-CL method was higher (by 0.09 nM) than the FI-DPD method for dissolved (< 0.4 μm) Fe, a difference that is comparable to the analytical blanks, which were as high as 0.13 nM ( CL) and 0.09 nM (DPD). There was generally good agreement between the FI-CL determinations for the < 0.03 mum size fraction and the FI-DPD determinations for the < 0.4 μm size fraction in freshly collected samples. Differences in total-dissolvable ( unfiltered) Fe concentrations determined by the two FI methods were more variable, reflecting the added complexity associated with the analysis of partially digested particulate material in these samples. Overall, however, the FI-CL determinations were significantly (P = 0.05) lower than the FI-DPD determinations for the unfiltered samples. Our results suggest that the observed, systematic inter-method differences reflect measurement of different physicochemical fractions of Fe present in seawater, such that colloidal and/or organic iron species are better determined by the FI-CL method than the FI-DPD method. This idea is supported by our observation that inter-method differences were largest for freshly collected acidified seawater, which suggests extended storage (>6 months) of acidified samples as a possible protocol for the determination of dissolved iron in seawater.
引用
收藏
页码:42 / 54
页数:13
相关论文
共 26 条
  • [1] Determination of iron in seawater
    Achterberg, EP
    Holland, TW
    Bowie, AR
    Fauzi, R
    Mantoura, C
    Worsfold, PJ
    [J]. ANALYTICA CHIMICA ACTA, 2001, 442 (01) : 1 - 14
  • [2] Determination of sub-nanomolar levels of iron in seawater using flow injection with chemiluminescence detection
    Bowie, AR
    Achterberg, EP
    Mantoura, RFC
    Worsfold, PJ
    [J]. ANALYTICA CHIMICA ACTA, 1998, 361 (03) : 189 - 200
  • [3] Shipboard analytical intercomparison of dissolved iron in surface waters along a north-south transect of the Atlantic Ocean
    Bowie, AR
    Achterberg, EP
    Blain, S
    Boye, M
    Croot, PL
    de Baar, HJW
    Laan, P
    Sarthou, G
    Worsfold, PJ
    [J]. MARINE CHEMISTRY, 2003, 84 (1-2) : 19 - 34
  • [4] Biogeochemistry of Fe and other trace elements (Al, Co, Ni) in the upper Atlantic Ocean
    Bowie, AR
    Whitworth, DJ
    Achterberg, EP
    Mantoura, RFC
    Worsfold, PJ
    [J]. DEEP-SEA RESEARCH PART I-OCEANOGRAPHIC RESEARCH PAPERS, 2002, 49 (04) : 605 - 636
  • [5] Real-time monitoring of picomolar concentrations of iron(II) in marine waters using automated flow injection-chemiluminescence instrumentation
    Bowie, AR
    Achterberg, EP
    Sedwick, PN
    Ussher, S
    Worsfold, PJ
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (21) : 4600 - 4607
  • [6] The fate of added iron during a mesoscale fertilisation experiment in the Southern Ocean
    Bowie, AR
    Maldonado, MT
    Frew, RD
    Croot, PL
    Achterberg, EP
    Mantoura, RFC
    Worsfold, PJ
    Law, CS
    Boyd, PW
    [J]. DEEP-SEA RESEARCH PART II-TOPICAL STUDIES IN OCEANOGRAPHY, 2001, 48 (11-12) : 2703 - 2743
  • [7] Bruland K.W., 2001, BIOGEOCHEMISTRY IRON, P255
  • [8] COALE KH, 1999, EOS T AM GEOPHYS UN, V80, P377
  • [9] *COMM REF MAT OC S, 2002, CHEM REF MAT SETT ST, P37
  • [10] Biogeochemical controls and feedbacks on ocean primary production
    Falkowski, PG
    Barber, RT
    Smetacek, V
    [J]. SCIENCE, 1998, 281 (5374) : 200 - 206