Ultrasonographic evaluation of focal hepatic lesions: Comparison of pulse inversion harmonic, tissue harmonic, and conventional imaging techniques

被引:47
作者
Jang, HJ [1 ]
Lim, HK [1 ]
Lee, WJ [1 ]
Kim, SH [1 ]
Kim, KA [1 ]
Kim, EY [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol,Kangnam Ku, Seoul 135710, South Korea
关键词
liver; lesions; pulse inversion harmonic imaging; tissue harmonic imaging; cysts; hepatic; metastases;
D O I
10.7863/ultra.19.5.293
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A prospective study was performed to evaluate whether pulse inversion harmonic imaging and tissue harmonic imaging improve the lesion conspicuity and change ultrasonographic characteristics of focal hepatic lesions. Three radiologists evaluated 97 focal hepatic lesions by consensus: cirrhosis-related nodules (n = 23), metastases (n = 23), hemangiomas (n = 27), and cysts (n = 24). In our study, pulse inversion harmonic imaging was judged superior to both tissue harmonic imaging and conventional imaging in conspicuity and overall quality for cirrhosis-related nodules, metastases, and cysts (P < 0.05). Compared with conventional imaging, both pulse inversion harmonic imaging and tissue harmonic imaging provided better conspicuity, clearer internal echogenicity, and stronger through-transmission of cysts (P < 0.05). Pulse inversion harmonic imaging was judged to be better in depicting internal morphology for cirrhosis-related nodules and metastases than conventional imaging (P < 0.05). For hemangiomas, no statistically significant difference was found in all parameters except better posterior enhancement by tissue harmonic imaging than other techniques. In conclusion, pulse inversion harmonic imaging short ed the best conspicuity and also enhanced characteristics of both cystic and solid hepatic lesions. Tissue harmonic imaging was judged superior to conventional imaging in evaluating cysts but was not beneficial for solid lesions. The results of this trial may be specific to the machine used for this study.
引用
收藏
页码:293 / 299
页数:7
相关论文
共 8 条
[1]   Finite amplitude distortion and its relationship to linear derating formulae for diagnostic ultrasound systems [J].
Christopher, T ;
Carstensen, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (08) :1103-1116
[2]   Real-time assessment of the parameter of nonlinearity in tissue using ''nonlinear shadowing'' [J].
Fatemi, M ;
Greenleaf, JF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (09) :1215-1228
[3]   Hepatic sonography: Comparison of tissue harmonic and standard sonography techniques [J].
Hann, LE ;
Bach, AM ;
Cramer, LD ;
Siegel, D ;
Yoo, HH ;
Garcia, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (01) :201-206
[4]   ATYPICAL HEPATIC HEMANGIOMA - A SUGGESTIVE SONOGRAPHIC MORPHOLOGY [J].
MOODY, AR ;
WILSON, SR .
RADIOLOGY, 1993, 188 (02) :413-417
[5]  
POWERS J, 1998, P 4 ANN S ULTR CONTR, P18
[6]   Tissue harmonic imaging sonography: Evaluation of image quality compared with conventional sonography [J].
Shapiro, RS ;
Wagreich, J ;
Parsons, RB ;
Stancato-Pasik, A ;
Yeh, HC ;
Lao, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (05) :1203-1206
[7]   THE DEVELOPMENT OF HARMONIC DISTORTION IN PULSED FINITE-AMPLITUDE ULTRASOUND PASSING THROUGH LIVER [J].
STARRITT, HC ;
DUCK, FA ;
HAWKINS, AJ ;
HUMPHREY, VF .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (12) :1401-1409
[8]   Nonlinear propagation applied to the improvement of resolution in diagnostic medical ultrasound [J].
Ward, B ;
Baker, AC ;
Humphrey, VF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (01) :143-154