Separation of steroidal drugs on porous graphitized carbon column

被引:16
作者
Forgács, E [1 ]
Cserháti, T [1 ]
机构
[1] Hungarian Acad Sci, Cent Res Inst Chem, H-1525 Budapest, Hungary
关键词
porous graphitized carbon column; steroid derivatives; mathematical data analysis;
D O I
10.1016/S0731-7085(98)00159-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The retention time of 11 steroidal drugs was determined on a porous graphitized carbon (PGC) column using water-tetrahydrofuran mixtures as eluents. Linear correlations were calculated between the logarithm of the capacity factor (k') and the tetrahydrofuran concentration in the eluent. To find the molecular parameters significantly influencing the retention the intercept and slope values of the above relationship were correlated with the physicochemical characteristics of steroidal drugs using principal component analysis (PCA). Both the slope and intercept values show high differences proving that steroidal drugs can be successfully separated on a PGC column. Five principal components explained > 90% of the total variance. Calculations indicated that both electrostatic interactions and sterical conditions can influence the retention of steroidal drugs on PGC column. (C) 1998 Elsevier Science B.V. AU rights reserved.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 23 条
[1]   CYCLODEXTRIN BONDED PHASE FOR LIQUID-CHROMATOGRAPHIC SEPARATION AND ANALYSIS OF SOME ORAL-CONTRACEPTIVES [J].
AHMED, AHN ;
ELGIZAWY, SM ;
OMAR, NM .
ANALYTICAL LETTERS, 1991, 24 (12) :2207-2216
[2]   Influence of organic modifiers on the retention characteristics of graphitized carbon column [J].
Balcan, M ;
Cserhati, T ;
Forgacs, E .
ANALYTICAL LETTERS, 1997, 30 (04) :883-893
[3]   SILICA-GEL AND CARBON COLUMN PACKINGS FOR USE IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BEREK, D ;
NOVAK, I .
CHROMATOGRAPHIA, 1990, 30 (9-10) :582-590
[4]  
BERRIDGE JC, 1988, J CHROMATOGR, V449, P317, DOI 10.1016/S0021-9673(00)94391-7
[5]   SILICA - BACKBONE MATERIAL OF LIQUID-CHROMATOGRAPHIC COLUMN PACKINGS [J].
BERTHOD, A .
JOURNAL OF CHROMATOGRAPHY, 1991, 549 (1-2) :1-28
[6]  
CLARK BJ, 1991, ADV STEROID ANAL 90, P129
[8]   APPLICATION OF MULTIVARIATE MATHEMATICAL STATISTICAL-METHODS FOR THE COMPARISON OF THE RETENTION BEHAVIOR OF POROUS GRAPHITIZED CARBON AND OCTADECYLSILICA COLUMNS [J].
FORGACS, E ;
CSERHATI, T ;
BORDAS, B .
ANALYTICA CHIMICA ACTA, 1993, 279 (01) :115-122
[9]   USE OF POROUS GRAPHITIZED CARBON COLUMN FOR DETERMINING TAXOL IN TAXUS-BACCATA [J].
FORGACS, E .
CHROMATOGRAPHIA, 1994, 39 (11-12) :740-742
[10]   POROUS GLASSY-CARBON, A NEW COLUMNS PACKING MATERIAL FOR GAS-CHROMATOGRAPHY AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GILBERT, MT ;
KNOX, JH ;
KAUR, B .
CHROMATOGRAPHIA, 1982, 16 :138-148