Detection of foreign bodies of the head with digital volume tomography

被引:26
作者
Eggers, G [1 ]
Mukhamadiev, D [1 ]
Hassfeld, S [1 ]
机构
[1] Univ Heidelberg Hosp, Dept Oral & Craniomaxillofacial Surg, Heidelberg, Germany
关键词
foreign bodies; tomography; X-ray computed;
D O I
10.1259/dmfr/22475468
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Foreign bodies occur as a sequela of trauma or therapeutic interventions. If the risks are not too high, therapy of choice is the removal of the foreign body. This is only possible if the existence of a foreign body is detected and it is localized accurately. Methods: The suitability of digital volume tomography (DVT) for the detection and localization of foreign bodies was investigated. Samples of various materials that are typically found as foreign bodies in the head and neck region were used. Results: All materials investigated are principally detectable with DVT. Highly radiopaque material was detectable down to small sizes. The detectability of less radiopaque substances like wood and resins was poor when located in soft tissue. Conclusion: DVT is an appropriate tool for the detection of radiopaque foreign bodies. However, foreign bodies made of wood and resin, although detectable by DVT, can be missed when located in muscular tissue. The detectability decreases further when the foreign body is located adjacent to a highly radiopaque tissue like bone. This has to be taken into consideration when using DVT for foreign body detection.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 29 条
[1]  
BOOTH PW, 1999, MAXILLOFACIAL SURG, V1
[2]   Detection and localization of steel intraocular foreign bodies using computed tomography - A comparison of helical and conventional axial scanning [J].
Chacko, JG ;
Figueroa, RE ;
Johnson, MH ;
Marcus, DM ;
Brooks, SE .
OPHTHALMOLOGY, 1997, 104 (02) :319-323
[3]  
Clark J C, 1987, Quintessence Int, V18, P653
[4]  
DORT JC, 1995, J OTOLARYNGOL, V24, P69
[5]  
Duker J, 1992, RONTGENDIAGNOSTIK PA
[6]  
EINISLIDIS G, 1997, BR J ORAL MAXILLOFAC, V35, P271
[7]   MAGNETIC-RESONANCE-IMAGING AND COMPUTED-TOMOGRAPHY IN A MODEL OF WOODEN FOREIGN-BODIES IN THE ORBIT [J].
GLATT, HJ ;
CUSTER, PL ;
BARRETT, L ;
SARTOR, K .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 6 (02) :108-114
[8]  
Grasser H, 1979, Zahnarztl Prax, V30, P151
[9]   A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine [J].
Hashimoto, K ;
Arai, Y ;
Iwai, K ;
Araki, M ;
Kawashima, S ;
Terakado, M .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2003, 95 (03) :371-377
[10]   Diagnosis goes digital [J].
Hatcher, DC ;
Aboudara, CL .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2004, 125 (04) :512-515