A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine

被引:237
作者
Hashimoto, K
Arai, Y
Iwai, K
Araki, M
Kawashima, S
Terakado, M
机构
[1] Nihon Univ, Sch Dent, Dept Radiol, Chiyoda Ku, Tokyo 1018310, Japan
[2] Nihon Univ, Sch Dent, Div Adv Dent Treatment, Tokyo 1018310, Japan
[3] Nihon Univ, Dent Res Ctr, Tokyo 1018310, Japan
[4] Matsumoto Dent Coll, Sch Dent, Dept Oral Radiol, Nagano, Japan
[5] Nihon Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Tokyo 1018310, Japan
[6] Nihon Univ, Sch Dent, Div System Biol & Oncol, Tokyo 1018310, Japan
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2003年 / 95卷 / 03期
关键词
D O I
10.1067/moe.2003.120
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. We sought to compare a new limited cone beam computed tomography (CT) machine for dental use (3DX) with the multidetector CT machine for image quality and skin doses. Study design. Images of the right maxillary central incisor and the left mandibular first molar of an anthropomorphic phantom were taken by both the 3DX and the multidetector CT. A 5-point method was used to evaluate the depiction of cortical and cancellous bone, enamel, dentin, pulp cavity, periodontal ligament space, lamina dura, and overall impressions. Furthermore, the skin doses for both modalities were compared. Results. The image quality of the 3DX was better than the multidetector CT for all items (P < .01). Moreover, the mean skin doses with the multidetector CT were 458 mSv per examination, whereas the doses with the 3DX were 1.19 mSv per examination. Conclusions. These results clearly indicate the superiority of the 3DX in the display of hard tissues in the dental area while substantially decreasing the dose to the patient.
引用
收藏
页码:371 / 377
页数:7
相关论文
共 16 条
[1]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[2]  
Arai Y, 1998, INT CONGR SER, V1165, P780
[3]  
Arai Y., 2000, DENT RADIOL, V40, P145
[4]   Multidetector-array CT: Once again, technology creates new opportunities [J].
Berland, LL ;
Smith, JK .
RADIOLOGY, 1998, 209 (02) :327-329
[5]  
FUKUDA K, 2000, JPN J DIAGNOSTIC IMA, V20, P1364
[6]   CT colonography: Single-versus multi-detector row imaging [J].
Hara, AK ;
Johnson, CD ;
MacCarty, RL ;
Welch, TJ ;
McCollough, CH ;
Harmen, WS .
RADIOLOGY, 2001, 219 (02) :461-465
[7]  
HONDA K, 2001, JPN J TOMOGR, V27, P193
[8]   COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .1. DESCRIPTION OF SYSTEM [J].
HOUNDFIELD, GN .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1016-1022
[9]   Four multidetector-row helical CT: Image quality and volume coverage speed [J].
Hu, H ;
He, HD ;
Foley, WD ;
Fox, SH .
RADIOLOGY, 2000, 215 (01) :55-62
[10]  
IWAI K, 2000, DENT RADIOL, V40, P251