Cationic polymer coatings for design of electroosmotic flow and control of DNA adsorption

被引:27
作者
Liu, XZ
Erickson, D
Li, DQ
Krull, UJ
机构
[1] Univ Toronto, Chem Sensors Grp, Dept Chem, Mississauga, ON L5L 1C6, Canada
[2] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
microfluidics; DNA microarray; electroosmotic flow; hybridization;
D O I
10.1016/j.aca.2003.10.075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A difficulty with the design and operation of an electrokinetically operated DNA hybridization microfluidic chip is the opposite direction of the electroosmotic flow and electrophoretic mobility of the oligonucleotides. This makes it difficult to simultaneously deliver targets and an appropriate hybridization buffer simultaneously to the probe sites. In this work we investigate the possibility of coating the inner walls of the microfluidic system with hexadimentrine bromide (polybrene, PB) and other cationic polymers in order to reverse the direction of electroosmotic flow so that it acts in the same direction as the electrophoretic transport of the oligonucleotides. The results indicated that the electroosmotic flow (EOF) in channels that were coated with the polymer could be reversed in I x TBE buffer or I x SSC buffer. Under these conditions, the DNA and EOF move in the same direction, and the flow can be used to deliver DNA to an area for selective hybridization within the channel. The effects of coating the surface of a nucleic acid microarray with polybrene were also studied to assess non-selective adsorption and stability. The polybrene coating significantly reduced the extent of non-selective adsorption of oligonucleotides in comparison to adsorption onto a glass surface, and the coating did not alter the extent of hybridization. The results suggest that use of the coating makes it possible to achieve semi-quantitative manipulation of nucleic acid oligomers for delivery to an integrated microarray or biosensor. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 22 条
[1]   Chip PCR .2. Investigation of different PCR amplification systems in microfabricated silicon-glass chips [J].
Cheng, J ;
Shoffner, MA ;
Hvichia, GE ;
Kricka, LJ ;
Wilding, P .
NUCLEIC ACIDS RESEARCH, 1996, 24 (02) :380-385
[2]   A matrix for DNA separation: Genotyping and sequencing using poly(vinylpyrrolidone) solution in uncoated capillaries [J].
Gao, QF ;
Yeung, ES .
ANALYTICAL CHEMISTRY, 1998, 70 (07) :1382-1388
[3]   A factorial analysis of silanization conditions for the immobilization of oligonucleotides on glass surfaces [J].
Halliwell, CM ;
Cass, AEG .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2476-2483
[4]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[5]   An AFM determination of the effects on surface roughness caused by cleaning of fused silica and glass substrates in the process of optical biosensor preparation [J].
Henke, L ;
Nagy, N ;
Krull, UJ .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :547-555
[6]   CURRENT-MONITORING METHOD FOR MEASURING THE ELECTROOSMOTIC FLOW-RATE IN CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1837-1838
[7]   Stable capillary coating with successive multiple ionic polymer layers [J].
Katayama, H ;
Ishihama, Y ;
Asakawa, N .
ANALYTICAL CHEMISTRY, 1998, 70 (11) :2254-2260
[8]   Chemical amplification: Continuous-flow PCR on a chip [J].
Kopp, MU ;
de Mello, AJ ;
Manz, A .
SCIENCE, 1998, 280 (5366) :1046-1048
[9]   SPR imaging measurements of 1-D and 2-D DNA microarrays created from microfluidic channels on gold thin films [J].
Lee, HJ ;
Goodrich, TT ;
Corn, RM .
ANALYTICAL CHEMISTRY, 2001, 73 (22) :5525-5531
[10]   Surface characterization of a silicon-chip-based DNA microarray [J].
Lenigk, R ;
Carles, M ;
Ip, NY ;
Sucher, NJ .
LANGMUIR, 2001, 17 (08) :2497-2501