The extracellular matrix, interstitial fluid and ions as a mechanical signal transducer in articular cartilage

被引:213
作者
Mow, VC
Wang, CC
Hung, CT
机构
[1] Columbia Univ, Dept Orthopaed Surg, Orthopaed Res Lab, New York, NY 10032 USA
[2] Columbia Univ, Ctr Biomed Engn, Orthopaed Res Lab, New York, NY 10032 USA
关键词
articular cartilage; mechanical signal transducer; explant loading experiment; flow-induced compaction;
D O I
10.1053/joca.1998.0161
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: (1) Provide an overview of the biomechanical factors that are required to analyze and interpret biological data from explant experiments; (2) Present a description of some of the mechano-electrochemical events which occur in cartilage explants during loading. Design: A thorough and provocative discussion on the effects of loading on articular cartilage will be presented. Five simplest loading cases are considered: hydrostatic pressure, osmotic pressure, permeation (pressure loading), confined compression and unconfined compression. Details of how such surface loadings are converted or transduced by the extracellular matrix (ECM) to pressure, fluid, solute and ion flows, deformation and electrical fields are discussed. Results: Similarities and differences in these quantities for the five types of loading are specifically noted. For example, it is noted that there is no practical mechanical loading condition that can be achieved in the laboratory to produce effects that are equal to the effects of osmotic pressure loading within the ECM. Some counter-intuitive effects from these loadings are also described. Further, the significance of flow-induced compression of the ECM is emphasized, since this frictional drag effect is likely to be one of the major effects of fluid flow through the porous-permeable ECM. Streaming potentials arising from the flow of ions past the fixed charges of the ECM are discussed in relation to the flow-induced compaction effect as well. Conclusion: Understanding the differences among these explant loading cases is important; it will help to provide greater insights to the mechano-electrochemical events which mediate metabolic responses of chondrocytes in explant loading experiments.
引用
收藏
页码:41 / 58
页数:18
相关论文
共 81 条
[21]   TRANSPORT OF FLUID AND IONS THROUGH A POROUS-PERMEABLE CHARGED-HYDRATED TISSUE, AND STREAMING POTENTIAL DATA ON NORMAL BOVINE ARTICULAR-CARTILAGE [J].
GU, WY ;
LAI, WM ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1993, 26 (06) :709-723
[22]   A mixture theory for charged-hydrated soft tissues containing multi-electrolytes: Passive transport and swelling behaviors [J].
Gu, WY ;
Lai, WM ;
Mow, VC .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (02) :169-180
[23]  
Guilak F, 1994, Osteoarthritis Cartilage, V2, P91, DOI 10.1016/S1063-4584(05)80059-7
[24]   Compression-induced changes in the shape and volume of the chondrocyte nucleus [J].
Guilak, F .
JOURNAL OF BIOMECHANICS, 1995, 28 (12) :1529-+
[25]   CHONDROCYTE DEFORMATION AND LOCAL TISSUE STRAIN IN ARTICULAR-CARTILAGE - A CONFOCAL MICROSCOPY STUDY [J].
GUILAK, F ;
RATCLIFFE, A ;
MOW, VC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (03) :410-421
[26]  
GUILAK F, 1998, IN PRESS J BIOMECHAN
[27]  
GUILAK F, 1997, BASIC ORTHOPAEDIC BI, P79
[28]   THE EFFECTS OF HYDROSTATIC-PRESSURE ON MATRIX SYNTHESIS IN ARTICULAR-CARTILAGE [J].
HALL, AC ;
URBAN, JPG ;
GEHL, KA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (01) :1-10
[29]   PROTEOGLYCANS - MANY FORMS AND MANY FUNCTIONS [J].
HARDINGHAM, TE ;
FOSANG, AJ .
FASEB JOURNAL, 1992, 6 (03) :861-870
[30]  
Helfferich F.G., 1962, Ion Exchange