Calculation of the isoelectric point of tryptic peptides in the pH 3.5-4.5 range based on adjacent amino acid effects

被引:20
作者
Cargile, Benjamin J. [1 ]
Sevinsky, Joel R. [1 ]
Essader, Amal S. [1 ]
Eu, Jerry P. [2 ]
Stephenson, James L., Jr. [1 ]
机构
[1] Res Triangle Inst, Mass Spectrometry Res Program, Durham, NC 27709 USA
[2] Duke Univ, Med Ctr, Div Pulm Allergy & Crit Care Med, Durham, NC USA
关键词
immobilized pH gradient; isoelectric focusing; mass spectrometry; peptide identification; pI calculation;
D O I
10.1002/elps.200700701
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Current algorithms for the calculation of peptide or protein pI, based on the charge associated with individual amino acids, can calculate pI values to within +/- 0.2 pI units. Here, we present a new pI calculation algorithm that takes into account the effect of adjacent amino acids on the pI value. The algorithm accounts for the effect of adjacent amino acids 3 residues away from a charged aspartic or glutamic acid, as well as effects on the free C terminus, and applies a correction term to the corresponding pK values. The correction increments are derived from a 5000-peptide training set using a genetic optimization approach. The accuracy of the new pI values obtained with this method approaches the error associated with the manufacture of the IPG strip (< +/- 0.03 pI units). The approach is demonstrated for cytosolic cell extracts derived from the breast-cancer cell line DU4475, and from membrane preparations from human lung-tissue samples. One potential application of a more highly accurate pI calculation is data filtering of MS/MS outputs that will allow for more complex database searches including gene finding, and validation, and detection of coding single-nucleotide polymorphisms in their expressed form.
引用
收藏
页码:2768 / 2778
页数:11
相关论文
共 33 条
[1]   ISOELECTRIC-FOCUSING IN IMMOBILIZED PH GRADIENTS - PRINCIPLE, METHODOLOGY AND SOME APPLICATIONS [J].
BJELLQVIST, B ;
EK, K ;
RIGHETTI, PG ;
GIANAZZA, E ;
GORG, A ;
WESTERMEIER, R ;
POSTEL, W .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1982, 6 (04) :317-339
[2]   THE FOCUSING POSITIONS OF POLYPEPTIDES IN IMMOBILIZED PH GRADIENTS CAN BE PREDICTED FROM THEIR AMINO-ACID-SEQUENCES [J].
BJELLQVIST, B ;
HUGHES, GJ ;
PASQUALI, C ;
PAQUET, N ;
RAVIER, F ;
SANCHEZ, JC ;
FRUTIGER, S ;
HOCHSTRASSER, D .
ELECTROPHORESIS, 1993, 14 (10) :1023-1031
[3]   Detection and validation of non-synonymous coding SNPs from orthogonal analysis of shotgun proteomics data [J].
Bunger, Maureen K. ;
Cargile, Benjamin J. ;
Sevinsky, Joel R. ;
Deyanova, Ekaterina ;
Yates, Nathan A. ;
Hendrickson, Ronald C. ;
Stephenson, James L., Jr. .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (06) :2331-2340
[4]   Quantitative phosphoproteomic analysis of the tumor necrosis factor pathway [J].
Cantin, GT ;
Venable, JD ;
Cociorva, D ;
Yates, JR .
JOURNAL OF PROTEOME RESEARCH, 2006, 5 (01) :127-134
[5]   Gel based isoelectric focusing of peptides and the utility of isoelectric point in protein identification [J].
Cargile, BJ ;
Bundy, JL ;
Freeman, TW ;
Stephenson, JL .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (01) :112-119
[6]   An alternative to tandem mass spectrometry: Isoelectric point and accurate mass for the identification of peptides [J].
Cargile, BJ ;
Stephenson, JL .
ANALYTICAL CHEMISTRY, 2004, 76 (02) :267-275
[7]   Potential for false positive identifications from large databases through tandem mass spectrometry [J].
Cargile, BJ ;
Bundy, JL ;
Stephenson, JL .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (05) :1082-1085
[8]   Immobilized pH gradients as a first dimension in shotgun proteomics and analysis of the accuracy of pI predictability of peptides [J].
Cargile, BJ ;
Talley, DL ;
Stephenson, JL .
ELECTROPHORESIS, 2004, 25 (06) :936-945
[9]   POSITIONAL REPRODUCIBILITY OF PROTEIN SPOTS IN 2-DIMENSIONAL POLYACRYLAMIDE-GEL ELECTROPHORESIS USING IMMOBILIZED PH GRADIENT ISOELECTRIC-FOCUSING IN THE FIRST DIMENSION - AN INTERLABORATORY COMPARISON [J].
CORBETT, JM ;
DUNN, MJ ;
POSCH, A ;
GORG, A .
ELECTROPHORESIS, 1994, 15 (8-9) :1205-1211
[10]   A comparison of immobilized pH gradient isoelectric focusing and strong-cation-exchange chromatography as a first dimension in shotgun proteomics [J].
Essader, AS ;
Cargile, BJ ;
Bundy, JL ;
Stephenson, JL .
PROTEOMICS, 2005, 5 (01) :24-34