Active Appearance-Motion Models for endocardial contour detection in time sequences of echocardiograms

被引:12
作者
Bosch, HG [1 ]
Mitchell, SC [1 ]
Lelieveldt, BPF [1 ]
Nijland, F [1 ]
Kamp, O [1 ]
Sonka, M [1 ]
Reiber, JHC [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, Div Image Proc, NL-2300 RC Leiden, Netherlands
来源
MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3 | 2001年 / 4322卷
关键词
deformable models; automatic border detection; Active Appearance Models; time sequences; motion ultrasound; cardiac; time-continuity;
D O I
10.1117/12.431095
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Active Appearance Models (AAM) are suitable for segmenting 2D images, but for image sequences time-continuous results are desired. Active Appearance-Motion Models (A-A-MM) model shape and appearance of the heart over the full cardiac cycle. Single-beat sequences are phase-normalized into stacks of 16 2D images. In a training set, corresponding shape points on the endocard are defined for each image based on expert drawn contours. Shape (2D) and intensity vectors are derived similar to AAM. Intensities are normalized non-linearly to handle ultrasound-specific problems. For all time frames, shape vectors are simply concatenated, as well as and intensity vectors. Principal Component Analysis extracts appearance eigenvariations over the cycle, capturing typical motion patterns. AAMMs perform segmentation on complete sequences by minimizing model-to-target differences, adjusting AAMM eigenvariation coefficients using gradient descent minimization. This results in time-continuous segmentation. The method was trained and tested on echocardiographic 4-chamber sequences of 129 unselected patients split randomly into a training set (n=65) and a test set (n=64). In all sequences, an independent expert manually drew endocardial contours. On the test set, fully automated AAMM performed well in 97% of cases (average distance 3.3 mm, 9.3 pixels, comparable to human inter- and intraobserver variabilities).
引用
收藏
页码:257 / 268
页数:4
相关论文
共 23 条
[1]  
[Anonymous], 2000, STAT MODELS APPEARAN
[2]  
BELOHLAVEK M, 1996, C VIS BIOM COMP VBC, P247
[3]  
Bosch HG, 2000, CIRCULATION, V102, P633
[4]  
Bosch J G, 1995, J Am Soc Echocardiogr, V8, P810, DOI 10.1016/S0894-7317(05)80005-7
[5]  
BOSCH JG, 1998, NEW CARDIOVASCULAR I, P363
[6]  
BOSCH JG, 2000, EUR J ECHOCARDIOG S2, V1, pS34
[7]  
BROTHERTON T, 1994, INT CONF ACOUST SPEE, P573
[8]   A multiple active contour model for cardiac boundary detection on echocardiographic sequences [J].
Chalana, V ;
Linker, DT ;
Haynor, DR ;
Kim, YM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (03) :290-298
[9]   USE OF ACTIVE SHAPE MODELS FOR LOCATING STRUCTURE IN MEDICAL IMAGES [J].
COOTES, TF ;
HILL, A ;
TAYLOR, CJ ;
HASLAM, J .
IMAGE AND VISION COMPUTING, 1994, 12 (06) :355-365
[10]   ACTIVE SHAPE MODELS - THEIR TRAINING AND APPLICATION [J].
COOTES, TF ;
TAYLOR, CJ ;
COOPER, DH ;
GRAHAM, J .
COMPUTER VISION AND IMAGE UNDERSTANDING, 1995, 61 (01) :38-59