A three-dimensional finite element model from computed tomography data: a semi-automated method

被引:73
作者
Cattaneo, PM
Dalstra, M
Frich, LH
机构
[1] Aarhus Univ Hosp, Orthopaed Res Lab, DK-8000 Aarhus C, Denmark
[2] Univ Aarhus, Royal Dent Coll, Dept Orthodont, Aarhus, Denmark
关键词
biomechanics; bone; computer simulation; glenoid; finite element analysis; image processing; scapula; tomography;
D O I
10.1243/0954411011533760
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Three-dimensional finite element analysis is one of the best ways to assess stress and strain distributions in complex bone structures. However, accuracy in the results may be achieved only when accurate input information is given. A semi-automated method to generate a finite element (FE)model using data retrieved from computed tomography (CT) was developed. Due to its complex and irregular shape, the glenoid part of a left embalmed scapula bone was chosen as working material. CT data were retrieved using a standard clinical CT scanner (Siemens Somatom Plus 2, Siemens AG, Germany). This was done to produce a method that could later be utilized to generate a patient-specific FE model. Different methods of converting Hounsfield unit (HU) values to apparent densities and subsequently to Young's moduli were tested. All the models obtained were loaded using three-dimensional loading conditions taken from literature, corresponding to an arm abduction of 90 degrees. Additional models with different amounts of elements were generated to verify convergence. Direct comparison between the models showed that the best method to convert HU values directly to apparent densities was to use different equations for cancellous and cortical bone. In this study, a reliable method of determining both geometrical data and bone properties from patient CT scans for the semi-automated generation of an FE model is presented.
引用
收藏
页码:203 / 213
页数:11
相关论文
共 27 条
[1]  
BAREA C, 1998, J BIOMECHANICS S, V1, P27
[2]   BEAM HARDENING IN X-RAY RECONSTRUCTIVE TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (03) :390-398
[3]   An improved method for finite element mesh generation of geometrically complex structures with application to the skullbase [J].
Camacho, DLA ;
Hopper, RH ;
Lin, GM ;
Myers, BS .
JOURNAL OF BIOMECHANICS, 1997, 30 (10) :1067-1070
[4]   COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[5]   Improving the local solution accuracy of large-scale digital image-based finite element analyses [J].
Charras, GT ;
Guldberg, RE .
JOURNAL OF BIOMECHANICS, 2000, 33 (02) :255-259
[6]  
Edidin A., 1991, T ORTHOP RES SOC, V16, P491
[7]  
ESSES SI, 1989, J BONE MINER RES, V4, P715
[8]  
FASSBERG RI, 1992, P 38 ANN M ORTH RES, P423
[9]   Bone strength and material properties of the glenoid [J].
Frich, LH ;
Jensen, NC ;
Odgaard, A ;
Pedersen, CM ;
Sojbjerg, JO ;
Dalstra, M .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 1997, 6 (02) :97-104
[10]  
HARP JH, 1994, CLIN ORTHOP RELAT R, P42