Characterization of surgical aerosols by the compact single-particle mass spectrometer LAMPAS 3

被引:9
作者
Hinz, K. -P. [1 ]
Gelhausen, E. [1 ]
Schaefer, K. -C. [1 ]
Takats, Z. [1 ]
Spengler, B. [1 ]
机构
[1] Univ Giessen, Inst Inorgan & Analyt Chem, D-35392 Giessen, Germany
关键词
Mass spectrometry; Single-particle analysis; In situ tissue analysis; Surgical aerosols; AIRBORNE PARTICLES; LASER-DESORPTION/IONIZATION; BIOLOGICAL TISSUES; IN-SITU; IDENTIFICATION; IONS;
D O I
10.1007/s00216-011-5465-6
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
A new method is presented using an optical particle counter and the compact mobile laser mass spectrometer LAMPAS 3 for in situ analysis of single particles generated by electrosurgical dissection of biological tissues. The instrumental performance is demonstrated for analysing aerosol particles formed during rapid thermal evaporation of porcine liver and porcine kidney tissues. Particle number concentrations of up to 5,000 particles per cubic centimetre were detected during surgical dissection. Chemical analysis of tissue particles was performed by bipolar time-of-flight mass spectrometry. The application of an online mass spectrometric particle analysis for surgical aerosols is reported here for the first time.
引用
收藏
页码:3165 / 3172
页数:8
相关论文
共 21 条
[1]
Identification of Biological Tissues by Rapid Evaporative Ionization Mass Spectrometry [J].
Balog, Julia ;
Szaniszlo, Tamas ;
Schaefer, Karl-Christian ;
Denes, Julia ;
Lopata, Antal ;
Godorhazy, Lajos ;
Szalay, Daniel ;
Balogh, Lajos ;
Sasi-Szabo, Laszlo ;
Toth, Mikos ;
Takats, Zoltan .
ANALYTICAL CHEMISTRY, 2010, 82 (17) :7343-7350
[2]
Real-time measurement of oligomeric species in secondary organic aerosol with the aerosol time-of-flight mass spectrometer [J].
Gross, DS ;
Gälli, ME ;
Kalberer, M ;
Prevot, ASH ;
Dommen, J ;
Alfarra, MR ;
Duplissy, J ;
Gaeggeler, K ;
Gascho, A ;
Metzger, A ;
Baltensperger, U .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2130-2137
[3]
MALDI of individual biomolecule-containing airborne particles in an ion trap mass spectrometer [J].
Harris, WA ;
Reilly, PTA ;
Whitten, WB .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4042-4050
[4]
He L, 1999, J MASS SPECTROM, V34, P909, DOI 10.1002/(SICI)1096-9888(199909)34:9<909::AID-JMS849>3.0.CO
[5]
2-A
[6]
Comparative parallel characterization of particle populations with two mass spectrometric systems LAMPAS 2 and SPASS [J].
Hinz, Klaus-Peter ;
Erdmann, Nicole ;
Gruening, Carsten ;
Spengler, Bernhard .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 258 (1-3) :151-166
[7]
Data processing in on-line laser mass spectrometry of inorganic, organic, or biological airborne particles [J].
Hinz, KP ;
Greweling, M ;
Drews, F ;
Spengler, B .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (07) :648-660
[8]
Aerosol single particle composition at the Jungfraujoch [J].
Hinz, KP ;
Trimborn, A ;
Weingartner, E ;
Henning, S ;
Baltensperger, U ;
Spengler, B .
JOURNAL OF AEROSOL SCIENCE, 2005, 36 (01) :123-145
[9]
Simultaneous detection of positive and negative ions from single airborne particles by real-time laser mass spectrometry [J].
Hinz, KP ;
Kaufmann, R ;
Spengler, B .
AEROSOL SCIENCE AND TECHNOLOGY, 1996, 24 (04) :233-242
[10]
Development of an aerosol mass spectrometer for size and composition analysis of submicron particles [J].
Jayne, JT ;
Leard, DC ;
Zhang, XF ;
Davidovits, P ;
Smith, KA ;
Kolb, CE ;
Worsnop, DR .
AEROSOL SCIENCE AND TECHNOLOGY, 2000, 33 (1-2) :49-70