In vivo finger flexor tendon force while tapping on a keyswitch

被引:39
作者
Dennerlein, JT
Diao, E
Mote, CD
Rempel, DM
机构
[1] Univ Calif San Francisco, Dept Med, San Francisco, CA USA
[2] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
[3] Univ Calif San Francisco, Dept Orthopaed Surg, San Francisco, CA 94143 USA
关键词
D O I
10.1002/jor.1100170205
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Force may be a risk factor for musculoskeletal. disorders of the upper extremity associated with typing and keying. However, the internal finger flexor tendon forces and their relationship to fingertip forces during rapid tapping on a keyswitch have not yet been measured in vivo. During the open carpal tunnel release surgery of five human subjects, a tendon-force transducer was inserted on the flexor digitorum superficialis of the long finger. During surgery, subjects tapped with the long finger on a computer keyswitch, instrumented with a keycap load cell. The average tendon maximum forces during a keystroke ranged from 8.3 to 16.6 N (mean = 12.9 N, SD = 3.3 N) for the subjects, four to seven times larger than the maximum forces observed at the fingertip. Tendon forces estimated from an isometric tendon-force model were only one to two times larger than tip force, significantly less than the observed tendon forces (p = 0.001). The force histories of the tendon during a keystroke were not proportional to fingertip force. First, the tendon-force histories did not contain the high-frequency fingertip force components observed as the tip impacts with the end of key travel. Instead, tendon tension during a keystroke continued to increase throughout the impact. Second, following the maximum keycap force, tendon tension during a keystroke decreased more slowly than fingertip force, remaining elevated approximately twice as long as the fingertip force. The prolonged elevation of tendon forces may be the result of residual eccentric muscle contraction or passive muscle forces, or both, which are additive to increasing extensor activity during the release phase of the keystroke.
引用
收藏
页码:178 / 184
页数:7
相关论文
共 26 条
[1]   DIRECT INVIVO TENDON FORCE MEASUREMENT SYSTEM [J].
AN, KN ;
BERGLUND, L ;
COONEY, WP ;
CHAO, EYS ;
KOVACEVIC, N .
JOURNAL OF BIOMECHANICS, 1990, 23 (12) :1269-1271
[2]   TENDON EXCURSION AND MOMENT ARM OF INDEX FINGER MUSCLES [J].
AN, KN ;
UEBA, Y ;
CHAO, EY ;
COONEY, WP ;
LINSCHEID, RL .
JOURNAL OF BIOMECHANICS, 1983, 16 (06) :419-425
[3]   ERGONOMICS CONSIDERATIONS IN HAND AND WRIST TENDINITIS [J].
ARMSTRONG, TJ ;
FINE, LJ ;
GOLDSTEIN, SA ;
LIFSHITZ, YR ;
SILVERSTEIN, BA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1987, 12A (05) :830-837
[4]   INVESTIGATION OF RELATIONSHIP BETWEEN DISPLACEMENTS OF FINGER WRIST JOINTS AND EXTRINSIC FINGER FLEXOR TENDONS [J].
ARMSTRONG, TJ ;
CHAFFIN, DB .
JOURNAL OF BIOMECHANICS, 1978, 11 (03) :119-128
[5]  
*BLS, 1995, REP SURV OCC INJ ILL
[6]   A KINEMATIC MODEL OF THE HUMAN HAND TO EVALUATE ITS PREHENSILE CAPABILITIES [J].
BUCHHOLZ, B ;
ARMSTRONG, TJ .
JOURNAL OF BIOMECHANICS, 1992, 25 (02) :149-162
[7]  
Chao E.Y., 1989, Biomechanics of the hand: a basic research study
[8]   Control strategies for finger movement during touch typing - The role of the extrinsic muscles during a keystroke [J].
Dennerlein, JT ;
Mote, CD ;
Rempel, DM .
EXPERIMENTAL BRAIN RESEARCH, 1998, 121 (01) :1-6
[9]   A low profile human tendon force transducer: The influence of tendon thickness on calibration [J].
Dennerlein, JT ;
Miller, JM ;
Mote, CD ;
Rempel, DM .
JOURNAL OF BIOMECHANICS, 1997, 30 (04) :395-397
[10]   Tensions of the flexor digitorum superficialis are higher than a current model predicts [J].
Dennerlein, JT ;
Diao, E ;
Mote, CD ;
Rempel, DM .
JOURNAL OF BIOMECHANICS, 1998, 31 (04) :295-301