Dynamic performance of ground-source heat pumps fitted with frequency inverters for part-load control

被引:50
作者
Lee, C. K. [1 ]
机构
[1] City Univ Hong Kong, Kowloon Tong, Hong Kong, Peoples R China
关键词
Ground-source heat pump; Ground heat exchanger; Borehole; Borefield; Frequency inverters; Vapor-compression cycle; SYSTEMS; EXCHANGERS; SIMULATION;
D O I
10.1016/j.apenergy.2010.04.029
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A model for a ground-source heat pump (GSHP) fitted with a variable-speed compressor was developed. A frequency inverter (FI) was used to modulate the GSHP capacity for improving the part-load performance of the system. Year-round dynamic simulations were made using TRNSYS for a general office based on the weather conditions in Hong Kong (HK). Kunming (KM) and Beijing (BJ). Different control schemes for the part-load control were tried and the results compared. It was found that the adoption of a variable-speed part-load control to the GSHP in both the cooling and heating mode operations was better. A reduction in the compressor energy input by minimum 27% could be achieved although a slight increase in the borefield fluid circulating pump energy consumption was inevitable. The peak borefield fluid temperatures were also reduced which allowed the borehole lengths to be shortened by at least 4% and the initial cost lowered accordingly. An economic analysis indicated that with the reduced borehole lengths, the payback periods were no longer than 0.4 months. This highlighted the merit of employing a variable-speed part-load in a GSHP system as the initial cost might also be saved besides the running costs under a wide range of climatic conditions. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3507 / 3513
页数:7
相关论文
共 20 条
[11]  
Seki W., 2004, MITSUBISHI HEAVY IND, V41, P1
[12]   Performance representation of variable-speed compressor for inverter air conditioners based on experimental data [J].
Shao, SQ ;
Shi, WX ;
Li, XT ;
Chen, HJ .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (08) :805-815
[13]  
Shi W.X., 2003, ASHRAE T, V109, P61
[14]  
Shu H., 2006, P 6 INT C ENH BUILD
[15]  
*U WI MAD SOL EN L, 2006, TRNSYS TRANS SYST SI
[16]  
VASQUEZ HG, 2004, ASHRAE T, V110, P67
[17]   Environmental performance and economic analysis of all-variable speed chiller systems with load-based speed control [J].
Yu, F. W. ;
Chan, K. T. .
APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) :1721-1729
[18]   Heat transfer analysis of boreholes in vertical ground heat exchangers [J].
Zeng, HY ;
Diao, NR ;
Fang, ZH .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (23) :4467-4481
[19]   Theoretical and basic experimental analysis on load adjustment of geothermal heat pump systems [J].
Zhao, L ;
Zhao, LL ;
Zhang, Q ;
Ding, GL .
ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (01) :1-9
[20]   Simulation and experimental validation of the variable-refrigerant-volume (VRV) air-conditioning system in EnergyPlus [J].
Zhou, Y. P. ;
Wu, J. Y. ;
Wang, R. Z. ;
Shiochi, S. ;
Li, Y. M. .
ENERGY AND BUILDINGS, 2008, 40 (06) :1041-1047