Determinants of endotoxin levels in carpets in New Zealand homes

被引:56
作者
Wickens, K
Douwes, J
Siebers, R
Fitzharris, P
Wouters, I
Doekes, G
Mason, K
Hearfield, M
Cunningham, M
Crane, J
机构
[1] Univ Otago, Wellington Sch Med, Wellington Asthma Res Grp, Wellington, New Zealand
[2] Univ Utrecht, Inst Risk Assessment Sci, Div Environm & Occupat Hlth, Utrecht, Netherlands
[3] Bldg Res Assoc New Zealand, Porirua, New Zealand
关键词
endotoxin; relative humidity; pets; cleaning; insulation; household occupancy;
D O I
10.1034/j.1600-0668.2003.00187.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Endotoxin in house dust has been shown to be associated with asthma severity. Little is known about the influence of housing characteristics on endotoxin distribution. Using standardized methods, dust was sampled from a 1m(2) site and the whole accessible carpet area in selected Wellington, New Zealand homes (n = 77). Endotoxin was measured using a Limulus Amoebocyte Lysate assay. Relative humidity and temperature were recorded using sensors placed in carpet bases. Questionnaires were used to collect information on housing characteristics. All analyses were performed for endotoxin units (EU)/mg and EU/m(2) for each site. Geometric mean endotoxin levels were 22.7 EU/mg [geometric standard deviation (GSD) = 2.4] or 30,544 EU/m(2) (GSD = 3.2) from the 1m(2) site, and 28.4 EU/mg (GSD = 3.4) or 5653 EU/m(2) (GSD = 6.4) from the whole room. After controlling for confounding, endotoxin was positively associated with dogs inside [geometric mean ratio (GMR): 0.9-2.0], total household occupants (GMR: 1.7-2.0, for 1 m(2) sample only), vacuum cleaners <1-year old (GMR: 2.3-2.7), reusing vacuum dust collection bags (GMR: 1.4-3.1), steamcleaning or shampooing the carpet (GMR: 1.4-2.2) and high relative humidity (GMR: 1.4-1.6). Lower endotoxin was associated with floor insulation (GMR: 0.4-0.8), and north-facing living rooms (GMR: 0.4-0.8). This study has identified home characteristics that could be modified to reduce endotoxin exposure.
引用
收藏
页码:128 / 135
页数:8
相关论文
共 28 条
[1]  
Braun-Fahrländer C, 1999, CLIN EXP ALLERGY, V29, P28, DOI 10.1046/j.1365-2222.1999.00479.x
[2]  
Chun D T, 2000, Appl Occup Environ Hyg, V15, P152
[3]  
Cunningham MJ, 1998, CLIN EXP ALLERGY, V28, P1104, DOI 10.1046/j.1365-2222.1998.00351.x
[4]   Exposure to house dust mite allergens and the clinical activity of asthma [J].
Custovic, A ;
Taggart, SCO ;
Francis, HC ;
Chapman, MD ;
Woodcock, A .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1996, 98 (01) :64-72
[5]   (1→3)-β-D-glucan and endotoxin in house dust and peak flow variability in children [J].
Douwes, J ;
Zuidhof, A ;
Doekes, G ;
van der Zee, S ;
Wouters, I ;
Boezen, HM ;
Brunekreef, B .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (04) :1348-1354
[6]   Fungal extracellular polysaccharides in house dust as a marker for exposure to fungi: Relations with culturable fungi, reported home dampness, and respiratory symptoms [J].
Douwes, J ;
van der Sluis, B ;
Doekes, G ;
van Leusden, F ;
Wijnands, L ;
van Strien, R ;
Verhoeff, A ;
Brunekreef, B .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1999, 103 (03) :494-500
[7]   Endotoxin and β(1→3)-glucan in house dust and the relation with home characteristics:: A pilot study in 25 German houses [J].
Douwes, J ;
Doekes, G ;
Heinrich, J ;
Koch, A ;
Bischof, W ;
Brunekreef, B .
INDOOR AIR, 1998, 8 (04) :255-263
[8]   INFLUENCE OF VARIOUS DUST SAMPLING AND EXTRACTION METHODS ON THE MEASUREMENT OF AIRBORNE ENDOTOXIN [J].
DOUWES, J ;
VERSLOOT, P ;
HOLLANDER, A ;
HEEDERIK, D ;
DOEKES, G .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1995, 61 (05) :1763-1769
[9]  
DOUWES J, 1997, INT J OCCUP ENV HEAL, V3, pS26
[10]   Allergen provocation augments endotoxin-induced nasal inflammation in subjects with atopic asthma [J].
Eldridge, MW ;
Peden, DB .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2000, 105 (03) :475-481