Enhanced systolic function of the right ventricle during respiratory distress syndrome in newborn lambs

被引:28
作者
De Vroomen, M
Steendijk, P
Cardozo, RHL
Brouwers, HHA
Van Bel, F
Baan, J
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, NL-2300 RC Leiden, Netherlands
[2] Juliana Childrens Hosp, Dept Neonatol, NL-2566 MJ The Hague, Netherlands
[3] Univ Med Ctr Utrecht, Wilhelmina Childrens Hosp, Dept Neonatol, NL-3508 AB Utrecht, Netherlands
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2001年 / 280卷 / 01期
关键词
biventricular function; end-systolic pressure-volume relation; homeometric autoregulation; pulmonary hypertension;
D O I
10.1152/ajpheart.2001.280.1.H392
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Respiratory distress syndrome (RDS) causes pulmonary hypertension. It is often suggested that this increased afterload for the right ventricle (RV) might lead to cardiac dysfunction. To examine this, we studied biventricular function in an experimental model. RDS was induced by lung lavages in seven newborn lambs. Five additional lambs served as controls. Cardiac function was quantified by indexes derived from end-systolic pressure-volume relations obtained by pressure-conductance catheters. After lung lavages, a twofold increase of mean pulmonary arterial pressure (from 15 to 34 mmHg) was obtained and lasted for the full 4-h study period. Stroke volume was maintained (5.2 +/- 0.6 ml at baseline and 6.1 +/- 1.4 ml at 4 h of RDS), while RV end-diastolic volume showed only a slight increase (from 6.5 +/- 2.3 ml at baseline to 7.7 +/- 1.3 ml at 4 h RDS). RV systolic function improved significantly, as indicated by a leftward shift and increased slope of the end-systolic pressure-volume relation. Left ventricular systolic function showed no changes. In control animals, pulmonary arterial pressure did not increase and right and left ventricular systolic function remained unaffected. In the face of increased RV afterload, the newborn heart is able to maintain cardiac output, primarily by improving systolic RV function through homeometric autoregulation.
引用
收藏
页码:H392 / H400
页数:9
相关论文
共 34 条
[1]   Validation of right and left ventricular conductance and echocardiography for cardiac function studies [J].
Amirhamzeh, MMR ;
Dean, DA ;
Jia, CX ;
Cabreriza, SE ;
Yano, OJ ;
Burkhoff, D ;
Spotnitz, HM .
ANNALS OF THORACIC SURGERY, 1996, 62 (04) :1104-1109
[2]   SIMULTANEOUS CONDUCTANCE CATHETER AND DIMENSION ASSESSMENT OF LEFT-VENTRICLE VOLUME IN THE INTACT ANIMAL [J].
APPLEGATE, RJ ;
CHENG, CP ;
LITTLE, WC .
CIRCULATION, 1990, 81 (02) :638-648
[3]   CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER [J].
BAAN, J ;
VANDERVELDE, ET ;
DEBRUIN, HG ;
SMEENK, GJ ;
KOOPS, J ;
VANDIJK, AD ;
TEMMERMAN, D ;
SENDEN, J ;
BUIS, B .
CIRCULATION, 1984, 70 (05) :812-823
[4]   VENTRICULAR PRESSURE VOLUME RELATIONS INVIVO [J].
BAAN, J ;
VANDERVELDE, ET ;
STEENDIJK, P .
EUROPEAN HEART JOURNAL, 1992, 13 :2-6
[5]   EFFECTS OF DAMAGING THE ENDOCARDIAL SURFACE ON THE MECHANICAL PERFORMANCE OF ISOLATED CARDIAC-MUSCLE [J].
BRUTSAERT, DL ;
MEULEMANS, AL ;
SIPIDO, KR ;
SYS, SU .
CIRCULATION RESEARCH, 1988, 62 (02) :358-366
[6]   THE ENDOCARDIAL ENDOTHELIUM [J].
BRUTSAERT, DL ;
ANDRIES, LJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 263 (04) :H985-H1002
[7]   Improved contractile performance of right ventricle in response to increased RV afterload in newborn lamb [J].
De Vroomen, M ;
Cardozo, RHL ;
Steendijk, P ;
Van Bel, F ;
Baan, J .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 278 (01) :H100-H105
[8]   RIGHT VENTRICULAR DIASTOLIC PRESSURE-VOLUME RELATIONS AND REGIONAL DIMENSIONS DURING ACUTE ALTERATIONS IN LOADING CONDITIONS [J].
DELLITALIA, LJ ;
WALSH, RA .
CIRCULATION, 1988, 77 (06) :1276-1282
[9]   MECHANICAL STIMULATION INDUCES INTERCELLULAR CALCIUM SIGNALING IN BOVINE AORTIC ENDOTHELIAL-CELLS [J].
DEMER, LL ;
WORTHAM, CM ;
DIRKSEN, ER ;
SANDERSON, MJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 264 (06) :H2094-H2102
[10]  
DICKSTEIN ML, 1995, CARDIOVASC RES, V29, P820, DOI 10.1016/0008-6363(96)88618-4