Movable contact less-conductivity detector for microchip capillary electrophoresis

被引:92
作者
Wang, J [1 ]
Chen, G [1 ]
Muck, A [1 ]
机构
[1] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
关键词
D O I
10.1021/ac030122k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new movable contactless-conductivity detection system for microchip capillary electrophoresis is introduced. Such a versatile system relies on positioning the detector at different points along the separation channel via "sliding" the electrode holder. The new movable microchip detection system offers distinct improvements compared to common fixed-location conductivity detectors. For example, placing the detector at different locations along the microchannel offers useful insights into the separation process. Three-dimensional plots of resolution/channel length/separation voltage can be used for optimizing the separation process and selecting the analysis time. The system enables rapid switching between "total" (unresolved) and "individual" (resolved/fingerprint) signals on the basis of placing the detector at the beginning and end of the separation channel, respectively. By moving the detector to a shorter effective separation length, after eluting fast-migrating ions, shorter analysis times can be achieved (through faster detection of late-eluting analytes). These and other improvements in the analytical performance and insights into the separation process are illustrated in connection with the detection of low-energy ionic explosives and nerve agent degradation products.
引用
收藏
页码:4475 / 4479
页数:5
相关论文
共 22 条
  • [11] Fractional factorial design optimization of the separation of pilocarpine and its degradation products by capillary electrophoresis
    Persson, K
    Astrom, O
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 697 (1-2): : 207 - 215
  • [12] Contactless conductivity detector for microchip capillary electrophoresis
    Pumera, M
    Wang, J
    Opekar, F
    Jelínek, I
    Feldman, J
    Löwe, H
    Hardt, S
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (09) : 1968 - 1971
  • [13] Micro total analysis systems. 1. Introduction, theory, and technology
    Reyes, DR
    Iossifidis, D
    Auroux, PA
    Manz, A
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (12) : 2623 - 2636
  • [14] Snyder J. J., 1979, INTRO MODERN LIQUID
  • [15] High-voltage capacitively coupled contactless conductivity detection for microchip capillary electrophoresis
    Tanyanyiwa, J
    Hauser, PC
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (24) : 6378 - 6382
  • [16] Tuma P, 2001, ELECTROANAL, V13, P989, DOI 10.1002/1521-4109(200108)13:12<989::AID-ELAN989>3.0.CO
  • [17] 2-C
  • [18] Single-channel microchip for fast screening and detailed identification of nitroaromatic explosives or organophosphate nerve agents
    Wang, J
    Pumera, M
    Chatrathi, MP
    Escarpa, A
    Musameh, M
    Collins, G
    Mulchandani, A
    Lin, YH
    Olsen, K
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (05) : 1187 - 1191
  • [19] Wang J, 2002, ELECTROPHORESIS, V23, P596, DOI 10.1002/1522-2683(200202)23:4<596::AID-ELPS596>3.0.CO
  • [20] 2-C