Colorectal hepatic metastases: Detection with SPIO-enhanced breath-hold MR imaging - Comparison of optimized sequences

被引:58
作者
Ward, J
Guthrie, JA
Wilson, D
Arnold, P
Lodge, JP
Toogood, GJ
Wyatt, JI
Robinson, PJ
机构
[1] St Jamess Univ Hosp, Dept Clin Radiol, Leeds LS9 7TF, W Yorkshire, England
[2] St Jamess Univ Hosp, Hepatobiliary & Transplantat Unit, Leeds LS9 7TF, W Yorkshire, England
[3] St Jamess Univ Hosp, Dept Histopathol, Leeds LS9 7TF, W Yorkshire, England
关键词
iron; liver neoplasms; metastases; MR; magnetic resonance (MR); comparative studies; contrast enhancement; contrast media;
D O I
10.1148/radiol.2283020376
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the accuracy of four breath-hold magnetic resonance (MR) imaging sequences to establish the most effective superparamagnetic iron oxide (SPIO)-enhanced sequence for detection of colorectal hepatic metastases. MATERIALS AND METHODS: Thirty-one patients with colorectal hepatic metastases underwent T1-weighted gradient-echo (GRE) and T2-weighted fast spin-echo (FSE) MR imaging before and after SPIO enhancement. Four sequences were optimized for lesion detection: T2-weighted FSE, multiecho data image combination (MEDIC), T2-weighted GRE with an 11-msec echo time (TE), and T2-weighted GRE with a 15-msec TE. Images were reviewed independently by three blinded observers. The accuracy of each sequence was measured by using alternative free-response receiver operating characteristic analysis. All results were correlated with findings at surgery, intraoperative ultrasonography, or histopathologic examination. Differences between the mean results of the three observers were measured by using the Student t test. RESULTS: Postcontrast T2-weighted GRE sequences were the most accurate and were significantly superior to postcontrast T2-weighted FSE and unenhanced sequences alone (P < .05). For all lesions that were malignant or smaller than I cm, respectively, mean accuracies of postcontrast sequences were 0.082 and 0.64 for T2-weighted FSE, 0.90 and 0.78 for MEDIC, 0.92 and 0.80 for GRE with an 11-msec TE, 0.93 and 0.82 for GRE with a 15-msec TE, and 0.81 and 0.62 for unenhanced sequences. CONCLUSION: Optimized SPIO-enhanced T2-weighted GRE combined with unenhanced T2-weighted FSE MR sequences were the most sensitive. Breath-hold FSE postcontrast sequences offer no improvement in sensitivity compared with unenhanced sequences alone. (C) RSNA, 2003.
引用
收藏
页码:709 / 718
页数:10
相关论文
共 25 条
[1]  
Abe Y, 2000, Radiat Med, V18, P97
[2]  
Ba-Ssalamah A, 2000, J MAGN RESON IMAGING, V11, P665, DOI 10.1002/1522-2586(200006)11:6<665::AID-JMRI13>3.0.CO
[3]  
2-D
[4]   LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING [J].
BELLIN, MF ;
ZAIM, S ;
AUBERTON, E ;
SARFATI, G ;
DURON, JJ ;
KHAYAT, D ;
GRELLET, J .
RADIOLOGY, 1994, 193 (03) :657-663
[5]   Hepatic lesion detection at MR imaging: A comparative study with four sequences [J].
Blakeborough, A ;
Ward, J ;
Wilson, D ;
Griffiths, M ;
Kajiya, Y ;
Guthrie, JA ;
Robinson, PJA .
RADIOLOGY, 1997, 203 (03) :759-765
[6]   APPLICATION OF FOURIER TRANSFORM SPECTROSCOPY TO MAGNETIC RESONANCE [J].
ERNST, RR ;
ANDERSON, WA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1966, 37 (01) :93-+
[7]   DETECTION OF HEPATIC METASTASES - COMPARISON OF CONTRAST-ENHANCED CT, UNENHANCED MR IMAGING, AND IRON-OXIDE ENHANCED MR IMAGING [J].
FRETZ, CJ ;
STARK, DD ;
METZ, CE ;
ELIZONDO, G ;
WEISSLEDER, R ;
SHEN, JH ;
WITTENBERG, J ;
SIMEONE, J ;
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (04) :763-770
[8]   VALUE OF T1-RELAXATION AND T2-RELAXATION TIMES FROM ECHOPLANAR MR IMAGING IN THE CHARACTERIZATION OF FOCAL HEPATIC-LESIONS [J].
GOLDBERG, MA ;
HAHN, PF ;
SAINI, S ;
COHEN, MS ;
REIMER, P ;
BRADY, TJ ;
MUELLER, PR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) :1011-1017
[9]   DETECTION OF LIVER METASTASES - COMPARISON OF SUPERPARAMAGNETIC IRON OXIDE-ENHANCED AND UNENHANCED MR-IMAGING ART 1.5 T WITH DYNAMIC CT, INTRAOPERATIVE US, AND PERCUTANEOUS US [J].
HAGSPIEL, KD ;
NEIDL, KFW ;
EICHENBERGER, AC ;
WEDER, W ;
MARINCEK, B .
RADIOLOGY, 1995, 196 (02) :471-478
[10]   STATISTICAL APPROACHES TO THE ANALYSIS OF RECEIVER OPERATING CHARACTERISTIC (ROC) CURVES [J].
MCNEIL, BJ ;
HANLEY, JA .
MEDICAL DECISION MAKING, 1984, 4 (02) :137-150