Simultaneous EEG-fMRI acquisition:: how far is it from being a standardized technique?

被引:20
作者
Garreffa, G
Bianciardi, M
Hagberg, GE
Macaluso, E
Marciani, MG
Maraviglia, B
Abbafati, M
Carnì, M
Bruni, I
Bianchi, L
机构
[1] Univ Roma La Sapienza, Dipartimento Fis, I-00185 Rome, Italy
[2] IRCCS, Fdn S Lucia, Lab Neurofisiopatol, I-00179 Rome, Italy
[3] Enrico Fermi Ctr, I-00184 Rome, Italy
[4] IRCCS, Fdn S Lucia, Lab Neuroimmagini, I-00179 Rome, Italy
[5] Univ Roma Tor Vergata, Dip Neurosci, Rome, Italy
[6] EBNeuro SPA, I-50127 Florence, Italy
关键词
EEG; fMRI; artefacts; synchronization; simultaneous acquisition;
D O I
10.1016/j.mri.2004.10.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Simultaneous EEG-fMRI is a powerful tool to study spontaneous and evoked brain activity because of the complementary advantages of the two techniques in terms of temporal and spatial resolution. In recent years, a significant number of scientific works have been published on this subject. However, many technical problems related to the intrinsic incompatibility of EEG And MRI methods are still not fully solved. Furthermore, simultaneous acquisition of EEG and event-related fMRI requires precise synchronization of all devices involved in the experimental setup. Thus, timing issue must be carefully considered in order to avoid significant methodological errors. The aim of the present work is to highlight and discuss some of technical and methodological open issues associated with the combined use of EEG and fMRI. These issues are presented in the context of preliminary data regarding simultaneous acquisition of event-related evoked potentials and BOLD images during a visual odd-ball paradigm. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:1445 / 1455
页数:11
相关论文
共 14 条
  • [1] Identification of EEG events in the MR scanner: The problem of pulse artifact and a method for its subtraction
    Allen, PJ
    Polizzi, G
    Krakow, K
    Fish, DR
    Lemieux, L
    [J]. NEUROIMAGE, 1998, 8 (03) : 229 - 239
  • [2] A method for removing imaging artifact from continuous EEG recorded during functional MRI
    Allen, PJ
    Josephs, O
    Turner, R
    [J]. NEUROIMAGE, 2000, 12 (02) : 230 - 239
  • [3] Stepping stone sampling for retrieving artifact-free electroencephalogram during functional magnetic resonance imaging
    Anami, K
    Mori, T
    Tanaka, F
    Kawagoe, Y
    Okamoto, J
    Yarita, M
    Ohnishi, T
    Yumoto, M
    Matsuda, H
    Saitoh, O
    [J]. NEUROIMAGE, 2003, 19 (02) : 281 - 295
  • [4] Quality of EEG in simultaneous EEG-fMRI for epilepsy
    Bénar, CG
    Aghakhani, Y
    Wang, YH
    Izenberg, A
    Al-Asmi, A
    Dubeau, F
    Gotman, J
    [J]. CLINICAL NEUROPHYSIOLOGY, 2003, 114 (03) : 569 - 580
  • [5] Motion and ballistocardiogram artifact removal for interleaved recording of EEG and EPs during MRI
    Bonmassar, G
    Purdon, PL
    Jääskeläinen, IP
    Chiappa, K
    Solo, V
    Brown, EN
    Belliveau, JW
    [J]. NEUROIMAGE, 2002, 16 (04) : 1127 - 1141
  • [6] Ballistocardiogram artifact reduction in the simultaneous acquisition of auditory ERPS and fMRI
    Ellingson, ML
    Liebenthal, E
    Spanaki, MV
    Prieto, TE
    Binder, JR
    Ropella, KM
    [J]. NEUROIMAGE, 2004, 22 (04) : 1534 - 1542
  • [7] Real-time MR artifacts filtering during continuous EEG/fMRI acquisition
    Garreffa, G
    Carnì, M
    Gualniera, G
    Ricci, GB
    Bozzao, L
    De Carli, D
    Morasso, P
    Pantano, P
    Colonnese, C
    Roma, V
    Maraviglia, B
    [J]. MAGNETIC RESONANCE IMAGING, 2003, 21 (10) : 1175 - 1189
  • [8] Simultaneous functional magnetic resonance imaging and electrophysiological recording
    HuangHellinger, FR
    Breiter, HC
    McCormack, G
    Cohen, MS
    Kwong, KK
    Sutton, JP
    Savoy, RL
    Weisskoff, RM
    Davis, TL
    Baker, JR
    Belliveau, JW
    Rosen, BR
    [J]. HUMAN BRAIN MAPPING, 1995, 3 (01) : 13 - 23
  • [9] MONITORING THE PATIENTS EEG DURING ECHO-PLANAR MRI
    IVES, JR
    WARACH, S
    SCHMITT, F
    EDELMAN, RR
    SCHOMER, DL
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1993, 87 (06): : 417 - 420
  • [10] Improved ballistocardiac artifact removal from the electroencephalogram recorded in fMRI
    Kim, KH
    Yoon, HW
    Park, HW
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2004, 135 (1-2) : 193 - 203