Can Differences in Corrected Coronary Opacification Measured With Computed Tomography Predict Resting Coronary Artery Flow?

被引:95
作者
Chow, Benjamin J. W. [1 ,2 ,3 ]
Kass, Malek
Gagne, Owen [1 ]
Chen, Li [4 ]
Yam, Yeung [1 ]
Dick, Alexander [1 ,2 ,3 ]
Wells, George A. [4 ]
机构
[1] Univ Ottawa, Inst Heart, Div Cardiol, Ottawa, ON K1Y 4W7, Canada
[2] Univ Ottawa, Inst Heart, Dept Radiol, Ottawa, ON K1Y 4W7, Canada
[3] Ottawa Hosp, Ottawa, ON, Canada
[4] Univ Ottawa, Inst Heart, Cardiovasc Res Methods Ctr, Ottawa, ON K1Y 4W7, Canada
基金
加拿大健康研究院; 加拿大创新基金会;
关键词
computed tomography; coronary angiography; coronary occlusion; functional stenosis; POSITRON-EMISSION-TOMOGRAPHY; DIAGNOSTIC PERFORMANCE; PROGNOSTIC VALUE; CT ANGIOGRAPHY; DISEASE; METAANALYSIS; SEVERITY; STENOSIS; SPECT; CATHETERIZATION;
D O I
10.1016/j.jacc.2010.09.072
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives A proof-of-concept study was undertaken to determine whether differences in corrected coronary opacification (CCO) within coronary lumen can identify arteries with abnormal resting coronary flow. Background Although computed tomographic coronary angiography can be used for the detection of obstructive coronary artery disease, it cannot reliably differentiate between anatomical and functional stenoses. Methods Computed tomographic coronary angiography patients (without history of revascularization, cardiac transplantation, and congenital heart disease) who underwent invasive coronary angiography were enrolled. Attenuation values of coronary lumen were measured before and after stenoses and normalized to the aorta. Changes in CCO were calculated, and CCO differences were compared with severity of coronary stenosis and Thrombolysis In Myocardial Infarction (TIMI) flow at the time of invasive coronary angiography. Results One hundred four coronary arteries (n = 52, mean age = 60.0 +/- 9.5 years; men = 71.2%) were assessed. Compared with normal arteries, the CCO differences were greater in arteries with computed tomographic coronary angiography diameter stenoses >= 50%. Similarly, CCO differences were greater in arteries with TIMI flow grade < 3 (0.406 +/- 0.226) compared with those with normal flow (TIMI flow grade 3) (0.078 +/- 0.078, p < 0.001). With CCO differences, abnormal coronary flow (TIMI flow grade < 3) was identified with a sensitivity and specificity, positive predictive value, and negative predictive value of 83.3% (95% confidence interval [CI]: 57.7 to 95.6%), 91.2% (95% CI: 75.2% to 97.7%), 83.3% (95% CI: 57.7% to 95.6%), and 91.2% (95% CI: 75.2% to 97.7%), respectively. Accuracy of this method was 88.5% with very good agreement (kappa = 0.75, 95% CI: 0.55 to 0.94). Conclusions Changes in CCO across coronary stenoses seem to predict abnormal (TIMI flow grade < 3) resting coronary blood flow. Further studies are needed to understand its incremental diagnostic value and its potential to measure stress coronary blood flow. (J Am Coll Cardiol 2011; 57: 1280-8) (C) 2011 by the American College of Cardiology Foundation
引用
收藏
页码:1280 / 1288
页数:9
相关论文
共 29 条
[1]   64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysis [J].
Abdulla, Jawdat ;
Abildstrom, Steen Z. ;
Gotzsche, Ole ;
Christensen, Erik ;
Kober, Lars ;
Torp-Pedersen, Christian .
EUROPEAN HEART JOURNAL, 2007, 28 (24) :3042-3050
[2]   CCS/CAR/CANM/CNCS/CanSCMR joint position statement on advanced noninvasive cardiac imaging using positron emission tomography, magnetic resonance imaging and multidetector computed tomographic angiography in the diagnosis and evaluation of ischemic heart disease - executive summary [J].
Beanlands, R. S. B. ;
Chow, B. J. W. ;
Dick, A. ;
Friedrich, M. G. ;
Gulenchyn, K. Y. ;
Kiess, M. ;
Leong-Poi, H. ;
Miller, R. M. ;
Nichol, G. ;
Freeman, M. ;
Bogaty, P. ;
Honos, G. ;
Hudon, G. ;
Wisenberg, G. ;
Van Berkom, J. ;
Williams, K. ;
Yoshinaga, K. ;
Graham, J. .
CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 (02) :107-119
[3]   Adenosine-Induced Stress Myocardial Perfusion Imaging Using Dual-Source Cardiac Computed Tomography [J].
Blankstein, Ron ;
Shturman, Leon D. ;
Rogers, Ian S. ;
Rocha-Filho, Jose A. ;
Okada, David R. ;
Sarwar, Ammar ;
Soni, Anand V. ;
Bezerra, Hiram ;
Ghoshhajra, Brian B. ;
Petranovic, Milena ;
Loureiro, Ricardo ;
Feuchtner, Gudrun ;
Gewirtz, Henry ;
Hoffmann, Udo ;
Mamuya, Wilfred S. ;
Brady, Thomas J. ;
Cury, Ricardo C. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (12) :1072-1084
[4]   Comparison of computed tomographic angiography versus rubidium-82 positron emission tomography for the detection of patients with anatomical coronary artery disease [J].
Chow, Benjamin J. W. ;
Dennie, Carole ;
Hoffmann, Udo ;
So, Derek ;
Dekemp, Robert A. ;
Ruddy, Terrence D. ;
Beanlands, Rob S. .
CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 (10) :801-807
[5]   Prognostic Value of 64-Slice Cardiac Computed Tomography Severity of Coronary Artery Disease, Coronary Atherosclerosis, and Left Ventricular Ejection Fraction [J].
Chow, Benjamin J. W. ;
Wells, George A. ;
Chen, Li ;
Yam, Yeung ;
Galiwango, Paul ;
Abraham, Arun ;
Sheth, Tej ;
Dennie, Carole ;
Beanlands, Rob S. ;
Ruddy, Terrence D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10) :1017-1028
[6]   Diagnostic Accuracy and Impact of Computed Tomographic Coronary Angiography on Utilization of Invasive Coronary Angiography [J].
Chow, Benjamin J. W. ;
Abraham, Arun ;
Wells, George A. ;
Chen, Li ;
Ruddy, Terrence D. ;
Yam, Yeung ;
Govas, Nayia ;
Galbraith, Phoebe Diane ;
Dennie, Carole ;
Beanlands, Rob S. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2009, 2 (01) :16-23
[7]  
Chow BJW, 2005, CAN J CARDIOL, V21, P933
[8]   Meta-analysis of fractional flow reserve versus quantitative coronary angiography and noninvasive imaging for evaluation of myocardial ischemia [J].
Christou, Maria A. C. ;
Siontis, George C. M. ;
Katritsis, Demosthenes G. ;
Ioannidis, John P. A. .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (04) :450-456
[9]   A POWER PRIMER [J].
COHEN, J .
PSYCHOLOGICAL BULLETIN, 1992, 112 (01) :155-159
[10]   Accuracy of 64-slice CT angiography for the detection of functionally relevant coronary stenoses as assessed with myocardial perfusion SPECT [J].
Gaemperli, Oliver ;
Schepis, Tiziano ;
Koepfli, Pascal ;
Valenta, Ines ;
Soyka, Jan ;
Leschka, Sebastian ;
Desbiolles, Lotus ;
Husmann, Lars ;
Alkadhi, Hatem ;
Kaufmann, Philipp A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (08) :1162-1171