Fabrication and experimental characterization of d31 telescopic piezoelectric actuators

被引:10
作者
Alexander, PW [1 ]
Brei, D
Miao, W
Halloran, JW
Gentilman, RL
Schmidt, GE
McGuire, PT
Hollenbeck, JR
机构
[1] Univ Michigan, Dept Mech Engn & Appl Mech, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Mat Sci & Engn, Ann Arbor, MI 48109 USA
[3] Mat Syst Inc, Littleton, MA 01460 USA
关键词
D O I
10.1023/A:1017985425629
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A popular and useful piezoelectric actuator is the stack. Unfortunately with this type of actuation architecture the long lengths normally required to obtain necessary displacements can pose packaging and buckling problems. To overcome these limitations, a new architecture for piezoelectric actuators has been developed called telescopic. The basic design consists of concentric shells interconnected by end-caps which alternate in placement between the two axial ends of the shells. This leads to a linear displacement amplification at the cost of force; yet the force remains at the same magnitude as a stack and significantly higher than bender type architectures. This paper describes the fabrication and experimental characterization of three different telescopic prototypes. The actuator prototypes discussed in this paper mark a definitive step forward in fabrication techniques for complex piezoceramic structures. Materials Systems, Inc. has adapted injection molding for the fabrication of net shape piezoceramic actuators. Injection molding provides several advantages over conventional fabrication techniques, including: high production rate, uniform part dimensions, uniform piezoelectric properties, and reduced fabrication and assembly costs. Acrylate polymerization, developed at the University of Michigan, is similar to gelcasting, but uses a nonaqueous slurry which facilitates the production of large, tall, complex components such as the telescopic actuator, and is ideal for the rapid manufacture of unique or small batch structures. To demonstrate these fabrication processes a five tube telescopic actuator was injection molded along with a very tall three tube actuator that was cast using the acrylate polymerization method. As a benchmark, a third actuator was built from off-the-shelf tubes that were joined with aluminum end-caps. Each prototype's free deflection behavior was experimentally characterized and the results of the testing are presented within this paper. (C) 2001 Kluwer Academic Publishers.
引用
收藏
页码:4231 / 4237
页数:7
相关论文
共 16 条
[1]  
BOWEN LJ, 1992, ISAF 92 : PROCEEDINGS OF THE EIGHTH IEEE INTERNATIONAL SYMPOSIUM ON APPLICATIONS OF FERROELECTRICS, P160, DOI 10.1109/ISAF.1992.300651
[2]  
BREI D, 1999, P ASME INT MECH ENG, P189
[3]  
BRIDGER K, 1996, SMART STRUCTURES MAT, P341
[4]  
Chu GTM, 1999, MATER RES SOC SYMP P, V542, P119
[5]  
Crumm AT, 1998, J AM CERAM SOC, V81, P1053, DOI 10.1111/j.1151-2916.1998.tb02448.x
[6]  
GENTILMAN R, 1994, CERAMIC T, V43, P239
[7]  
HAERTLING GH, 1994, AM CERAM SOC BULL, V73, P93
[8]   Development of low-toxicity gelcasting systems [J].
Janney, MA ;
Omatete, OO ;
Walls, CA ;
Nunn, SD ;
Ogle, RJ ;
Westmoreland, G .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1998, 81 (03) :581-591
[9]  
OMATETE OO, 1991, CERAM B, V70, P1642
[10]  
PANDA RK, 1998, P 11 IEEE INT S APPL, P265