Impact comparison of PV system integration into rural and urban feeders

被引:33
作者
Hernandez, J. C. [2 ]
Medina, A. [2 ]
Jurado, F. [1 ]
机构
[1] Univ Jaen, EPS, Dept Elect Engn, Jaen 23700, Spain
[2] Univ Jaen, EPS, Dept Elect Engn, Jaen 23071, Spain
关键词
photovoltaic power systems; power distribution planning; rural area; urban area;
D O I
10.1016/j.enconman.2007.10.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper is directed to evaluate the impact that the future widespread use of photovoltaic grid connected systems (PVGCSs) will have on feeder operation. With it view to achieve a global vision of this impact, the present work investigates representative feeders located in different latitudes. Actual rural and urban distribution feeders belonging to the Spanish electric utility have been selected and analyzed in both northern and southern latitudes. The analysis identifies the operating variables to assess the PV impact in the different feeders. These critical variables are related to the design and performance characteristics of the feeder. Meteorological conditions at the installation site, load patterns, PV allocation and penetration are the main factors affecting this PV impact. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1747 / 1765
页数:19
相关论文
共 41 条
[1]   Optimizing electrical load pattern in Kuwait using grid connected photovoltaic systems [J].
Al-Hasan, AY ;
Ghoneim, AA ;
Abdullah, AH .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (04) :483-494
[2]   ESTIMATION OF THE EFFECTS OF AN INTENSIVE SOLAR INTERVENTION IN THE HISTORICAL CENTER OF JAEN (SPAIN) [J].
ALMONACID, G ;
NOFUENTES, G ;
AGUILAR, JD ;
DELACASA, J ;
GARRIDO, A .
PROGRESS IN PHOTOVOLTAICS, 1995, 3 (03) :197-209
[3]   Technical assessment of electric utility-interactive residential photovoltaic power systems [J].
Aly, GEM ;
El-Zeftawy, AA ;
El-Hefnawy, AA ;
Eraky, SA .
ELECTRIC POWER SYSTEMS RESEARCH, 1999, 51 (03) :175-185
[4]  
[Anonymous], 2001, EN 50160:2010
[5]   The effect of tilt angle, air pollution on performance of photovoltaic systems in Tehran [J].
Asl-Soleimani, E ;
Farhangi, S ;
Zabihi, MS .
RENEWABLE ENERGY, 2001, 24 (3-4) :459-468
[6]   PV system measurements and monitoring - The European experience [J].
Blaesser, G .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 1997, 47 (1-4) :167-176
[7]   Application of load survey systems to proper tariff design [J].
Chen, CS ;
Hwang, JC ;
Huang, CW .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1997, 12 (04) :1746-1751
[8]   Determination of customer load characteristics by load survey system at taipower [J].
Chen, CS ;
Hwang, JC ;
Tzeng, YM ;
Huang, CW ;
Cho, MY .
IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (03) :1430-1436
[9]   Synthesis of power system load profiles by class load study [J].
Chen, CS ;
Kang, MS ;
Hwang, JC ;
Huang, CW .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2000, 22 (05) :325-330
[10]   OPTIMIZING THE INTEGRATION OF PHOTOVOLTAIC SYSTEMS WITH ELECTRIC UTILITIES [J].
CHOWDHURY, BH .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1992, 7 (01) :72-78