Normal and abnormal pulmonary ventilation: Visualization at hyperpolarized He-3 MR imaging

被引:222
作者
Kauczor, HU
Hofmann, D
Kreitner, KF
Nilgens, H
Surkau, R
Heil, W
Potthast, A
Knopp, MV
Otten, EW
Thelen, M
机构
[1] UNIV MAINZ,INST PHYS,D-55131 MAINZ,GERMANY
[2] SIEMENS MED SYST INC,ERLANGEN,GERMANY
[3] GERMAN CANC RES CTR,DEPT ONCOL DIAGNOST & THERAPY,D-6900 HEIDELBERG,GERMANY
关键词
lung; MR; magnetic resonance (MR); contrast enhancement; magnetic resonance (MR; nuclei other than H;
D O I
10.1148/radiology.201.2.8888259
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the feasibility of helium-3 magnetic resonance (MR) imaging with a three-dimensional fast low-angle shot (FLASH) sequence, He-3 gas (volume, 300 mt; pressure, 3 x 10(5) Pa; polarized up to 45% by means of optimal pumping) was inhaled by five healthy volunteers and five patients with pulmonary diseases. All breath-hold examinations (22 - 42 seconds) were completed successfully. Normal ventilation tvas depicted with homogeneous high signal intensity, lesions were depicted as causing defects, and obstructive lung disease was depicted with severely inhomogeneous signal intensity.
引用
收藏
页码:564 / 568
页数:5
相关论文
共 11 条
  • [1] MEASUREMENT OF XE-129 T1 IN BLOOD TO EXPLORE THE FEASIBILITY OF HYPERPOLARIZED XE-129 MRI
    ALBERT, MS
    SCHEPKIN, VD
    BUDINGER, TF
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (06) : 975 - 978
  • [2] ALBERT MS, 1994, NATURE, V370, P199, DOI 10.1038/370199a0
  • [3] Nuclear magnetic resonance imaging of airways in humans with use of hyperpolarized He-3
    Bachert, P
    Schad, LR
    Bock, M
    Knopp, MV
    Ebert, M
    Grossmann, T
    Heil, W
    Hofmann, D
    Surkau, R
    Otten, EW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) : 192 - 196
  • [4] STUDY OF MECHANICAL COMPRESSION OF SPIN-POLARIZED HE-3 GAS
    BECKER, J
    HEIL, W
    KRUG, B
    LEDUC, M
    MEYERHOFF, M
    NACHER, PJ
    OTTEN, EW
    PROKSCHA, T
    SCHEARER, LD
    SURKAU, R
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (1-2) : 45 - 51
  • [5] In vivo He-3 MR images of guinea pig lungs
    Black, RD
    Middleton, HL
    Cates, GD
    Cofer, GP
    Driehuys, B
    Happer, W
    Hedlund, LW
    Johnson, GA
    Shattuck, MD
    Swartz, JC
    [J]. RADIOLOGY, 1996, 199 (03) : 867 - 870
  • [6] Nuclear magnetic resonance imaging with hyperpolarised helium-3
    Ebert, M
    Grossmann, T
    Heil, W
    Otten, WE
    Surkau, R
    Leduc, M
    Bachert, P
    Knopp, MV
    Schad, LR
    Thelen, M
    [J]. LANCET, 1996, 347 (9011) : 1297 - 1299
  • [7] A DENSE POLARIZED HE-3 TARGET BASED ON COMPRESSION OF OPTICALLY PUMPED GAS
    ECKERT, G
    HEIL, W
    MEYERHOFF, M
    OTTEN, EW
    SURKAU, R
    WERNER, M
    LEDUC, M
    NACHER, PJ
    SCHEARER, LD
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2) : 53 - 65
  • [8] VERY LONG NUCLEAR-RELAXATION TIMES OF SPIN-POLARIZED HELIUM-3 IN METAL-COATED CELLS
    HEIL, W
    HUMBLOT, H
    OTTEN, E
    SCHAFER, M
    SARKAU, R
    LEDUC, M
    [J]. PHYSICS LETTERS A, 1995, 201 (04) : 337 - 343
  • [9] HEIL W, IN PRESS J NEUTRON R
  • [10] Human lung air spaces: Potential for MR imaging with hyperpolarized He-3
    MacFall, JR
    Charles, HC
    Black, RD
    Middleton, H
    Swartz, JC
    Saam, B
    Driehuys, B
    Erickson, C
    Happer, W
    Cates, GD
    Johnson, GA
    Ravin, CE
    [J]. RADIOLOGY, 1996, 200 (02) : 553 - 558