Catheter manipulations and the risk of catheter-associated bloodstream infection in neonatal intensive care unit patients

被引:84
作者
Mahieu, LM
De Dooy, JJ
Lenaerts, AE
Leven, MM
De Muynck, AO
机构
[1] Univ Antwerp Hosp, Dept Paediat, Div Neonatol, B-2650 Antwerp, Belgium
[2] Univ Antwerp Hosp, Dept Clin Microbiol, B-2650 Antwerp, Belgium
[3] Inst Trop Med, Dept Clin Sci, Antwerp, Belgium
关键词
bloodstream infection; neonates; catheter; cohort studies; manipulation;
D O I
10.1053/jhin.2000.0930
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A prospective cohort study was performed to evaluate the influence of catheter manipulations on catheter associated bloodstream infection (CABSI) in neonates. Neonates admitted between 1 November 1993 and 31 October 1994 at the neonatal intensive care unit of a university hospital were included in the study. Seventeen episodes of CABSI occurred in 357 central catheters over a period of 3470 catheter-days, with a cumulative incidence of 4.7/100 catheters and an incidence density of 4.9/1000 catheter-days. Patient- and catheter-related risk factors independently associated with CABSI were: catheter hub colonization (odds ratio [OR] = 32.6, 95% confidence interval [95% CI] = 4.3-249), extremely low weight (< 1000 gram) at time of catheter insertion (OR=9.1, 95% CI=1.9-42.2). Catheter manupulations independently associated with CABSI were disinfection of the catheter hub (OR=1.2, 95% CI=1.1-1.3), blood sampling (OR=1.4, 95% CI=1.1-1.8), heparinization (OR=0.9, 95%, CI=0.8-1.0) and antisepsis of exit site (OR=0.9, 95% CI=0.8-1.0). This study indicates that certain manipulations (e.g. blood sampling through the central line) and disconnection of the central venous catheter, which necessitates disinfection of the catheter hub, increase the risk of CABSI, while other procedures (e.g. heparinization and exit site antisepsis), protect against CABSI in neonates. (C) 2001 The Hospital Infection Society.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 21 条
[1]   Intravenous lipid emulsions are the major determinant of coagulase-negative staphylococcal bacteremia in very low birth weight newborns [J].
Avila-Figueroa, C ;
Goldmann, DA ;
Richardson, DK ;
Gray, JE ;
Ferrari, A ;
Freeman, J .
PEDIATRIC INFECTIOUS DISEASE JOURNAL, 1998, 17 (01) :10-17
[2]  
BELLANTI JA, 1981, NEONATOLOGY PATHOPHY, P701
[3]   The potential for catheter microbial contamination from a needleless connector [J].
Brown, JD ;
Moss, HA ;
Elliott, TSJ .
JOURNAL OF HOSPITAL INFECTION, 1997, 36 (03) :181-189
[4]   Prevention of vascular catheter-related infections [J].
Darouiche, RO .
NETHERLANDS JOURNAL OF MEDICINE, 1999, 55 (03) :92-99
[5]   EFFECTS OF HEPARIN AND CHLORBUTOL ON BACTERIAL-COLONIZATION OF INTRAVASCULAR CANNULAE IN AN INVITRO MODEL [J].
ELLIOTT, TSJ ;
CURRAN, A .
JOURNAL OF HOSPITAL INFECTION, 1989, 14 (03) :193-200
[6]   ASSOCIATION OF INTRAVENOUS LIPID EMULSION AND COAGULASE-NEGATIVE STAPHYLOCOCCAL BACTEREMIA IN NEONATAL INTENSIVE-CARE UNITS [J].
FREEMAN, J ;
GOLDMANN, DA ;
SMITH, NE ;
SIDEBOTTOM, DG ;
EPSTEIN, MF ;
PLATT, R .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (05) :301-308
[7]   ADDITION OF SODIUM METABISULFITE TO LEFT ATRIAL CATHETER INFUSATES AS A MEANS OF PREVENTING BACTERIAL-COLONIZATION OF THE CATHETER TIP [J].
FREEMAN, R ;
HOLDEN, MP ;
LYON, R ;
HJERSING, N .
THORAX, 1982, 37 (02) :142-144
[8]   A CLUSTER OF COAGULASE-NEGATIVE STAPHYLOCOCCAL BACTEREMIAS ASSOCIATED WITH PERIPHERAL VASCULAR CATHETER COLONIZATION IN A NEONATAL INTENSIVE-CARE UNIT [J].
GELLERT, GA ;
EWERT, DP ;
BENDANA, N ;
SMITH, E ;
BECKSAGUE, C ;
CHIN, A ;
MILLER, JM ;
HANCOCK, G ;
WELCH, W ;
MASCOLA, L .
AMERICAN JOURNAL OF INFECTION CONTROL, 1993, 21 (01) :16-20
[9]   A 10-YEAR REVIEW OF NEONATAL SEPSIS AND COMPARISON WITH THE PREVIOUS 50-YEAR EXPERIENCE [J].
GLADSTONE, IM ;
EHRENKRANZ, RA ;
EDBERG, SC ;
BALTIMORE, RS .
PEDIATRIC INFECTIOUS DISEASE JOURNAL, 1990, 9 (11) :819-825
[10]  
GRAY JE, 1995, PEDIATRICS, V95, P225