Midterm Results of Primary Total Hip Arthroplasty Using Highly Cross-Linked Polyethylene

被引:47
作者
Lee, Ji-Ho [1 ]
Lee, Byung Woo [1 ]
Lee, Byoung-Joo [2 ]
Kim, Shin-Yoon [1 ]
机构
[1] Kyungpook Natl Univ, Grad Sch Med, Dept Orthoped Surg, Taegu, South Korea
[2] Kyungsan Saemyung Hosp, Dept Orthoped Surg, Taegu, South Korea
关键词
highly cross-linked polyethylene; linear wear rate; osteolysis; CLINICAL-PERFORMANCE; FEMORAL COMPONENTS; FOLLOW-UP; WEAR RATE; THA; ASSOCIATION; REPLACEMENT; OSTEOLYSIS; FIXATION; UHMWPE;
D O I
10.1016/j.arth.2011.03.015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The purpose of this study was to investigate the results of 113 total hip arthroplasties in 109 patients using highly cross-linked polyethylene (HXLPE) after midterm (minimum 7 years) follow-up retrospectively. The mean age at the time of operation was 57 years. Preoperative diagnosis was osteonecrosis in 81 hips and other diagnosis in 32 hips. There was no component loosening. Acetabular osteolysis was found in 12 hips (10.6 /0). Mean linear HXLPE wear rate was 0.031 +/- 0.012 mm/y. We analyzed the relationship between HXLPE wear rate and several variables influencing HXLPE wear. Only the cup position was related with wear rate of HXLPE significantly (P < .05). The results of total hip arthroplasties using HXLPE showed excellent results with decreased wear rate and low incidence of osteolysis after midterm follow-up.
引用
收藏
页码:1014 / 1019
页数:6
相关论文
共 32 条
[1]
Minimum 6-year followup of highly cross-linked polyethylene in THA [J].
Bragdon, Charles R. ;
Kwon, Young Min ;
Geller, Jeffrey A. ;
Greene, Meridith E. ;
Freiberg, Andrew A. ;
Harris, William H. ;
Malchau, Henrik .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) :122-127
[2]
Comparison of cross-linked polyethylene materials for orthopaedic applications [J].
Collier, JP ;
Currier, BH ;
Kennedy, FE ;
Currier, JH ;
Timmins, GS ;
Jackson, SK ;
Brewer, RL .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (414) :289-304
[3]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[4]
Devane PA, 1999, CLIN ORTHOP RELAT R, P59
[5]
Highly cross-linked polyethylene in cemented THA -: Randomized study of 61 hips [J].
Digas, G ;
Kärrholm, J ;
Thanner, J ;
Malchau, H ;
Herberts, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :126-138
[6]
Clinical performance of a durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years [J].
Dorr, LD ;
Wan, ZN ;
Shahrdar, C ;
Sirianni, L ;
Boutary, M ;
Yun, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (08) :1816-1821
[7]
Characterization of long-term femoral-head-penetration rates - Association with and prediction of osteolysis [J].
Dowd, JE ;
Sychterz, CJ ;
Young, AM ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (08) :1102-1107
[8]
A literature review of the association between wear rate and osteolysis in total hip arthroplasty [J].
Dumbleton, JH ;
Manley, MT ;
Edidin, AA .
JOURNAL OF ARTHROPLASTY, 2002, 17 (05) :649-661
[9]
The basis for a second-generation highly cross-linked UHMWPE [J].
Dumbleton, John H. ;
D'Antonio, James A. ;
Manley, Michael T. ;
Capello, William N. ;
Wang, Aiguo .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) :265-271
[10]
Can the Volume of Pelvic Osteolysis be Calculated without Using Computed Tomography? [J].
Egawa, Hiroshi ;
Powers, Cara C. ;
Beykirch, Sarah E. ;
Hopper, Robert H., Jr. ;
Engh, C. Anderson, Jr. ;
Engh, Charles A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) :181-187