Nanoelectrospray ion generation for high-throughput mass spectrometry using a micromachined ultrasonic ejector array

被引:32
作者
Aderogba, S
Meacham, JM
Degertekin, FL
Fedorov, AG [1 ]
Fernandez, FM
机构
[1] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Chem & Biochem, Atlanta, GA 30332 USA
关键词
D O I
10.1063/1.1929878
中图分类号
O59 [应用物理学];
学科分类号
摘要
Ultrasonic electrospray ionization (ESI) for high-throughput mass spectrometry is demonstrated using a silicon micromachined microarray. The device uses a micromachined ultrasonic atomizer operating in the 900 kHz-2.5 MHz range for droplet generation and a metal electrode in the fluid cavity for ionization. Since the atomization and ionization processes are separated, the ultrasonic ESI source shows the potential for operation at low voltages with a wide range of solvents in contrast with conventional capillary ESI technology. This is demonstrated using the ultrasonic ESI microarray to obtain the mass spectrum of a 10 m M reserpine sample on a time of flight mass spectrometer with 197:1 signal-to-noise ratio at an ionization potential of 200 V. (c) 2005 American Institute of Physics.
引用
收藏
页码:1 / 3
页数:3
相关论文
共 16 条
[1]   ULTRASONICALLY ASSISTED ELECTROSPRAY-IONIZATION FOR LC/MS DETERMINATION OF NUCLEOSIDES FROM A TRANSFER-RNA DIGEST [J].
BANKS, JF ;
SHEN, S ;
WHITEHOUSE, CM ;
FENN, JB .
ANALYTICAL CHEMISTRY, 1994, 66 (03) :406-414
[2]   Microfluidic devises connected to fused-silica capillaries with minimal dead volume [J].
Bings, NH ;
Wang, C ;
Skinner, CD ;
Colyer, CL ;
Thibault, P ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3292-3296
[3]   A new method for significantly reducing drop radius without reducing nozzle radius in drop-on-demand drop production [J].
Chen, AU ;
Basaran, OA .
PHYSICS OF FLUIDS, 2002, 14 (01) :L1-L4
[4]  
Gaskell SJ, 1997, J MASS SPECTROM, V32, P677, DOI 10.1002/(SICI)1096-9888(199707)32:7<677::AID-JMS536>3.3.CO
[5]  
2-7
[6]   Two-dimensional microfabricated sources for nanoelectrospray [J].
Le Gac, S ;
Arscott, S ;
Cren-Olivé, C ;
Rolando, C .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (12) :1259-1264
[7]   Separation and identification of peptides from gel-isolated membrane proteins using a microfabricated device for combined capillary electrophoresis/nanoelectrospray mass spectrometry [J].
Li, JJ ;
Kelly, JF ;
Chemushevich, I ;
Harrison, DJ ;
Thibault, P .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :599-609
[8]   Integration of microfabricated devices to capillary electrophoresis-electrospray mass spectrometry using a low dead volume connection: Application to rapid analyses of proteolytic digests [J].
Li, JJ ;
Thibault, P ;
Bings, NH ;
Skinner, CD ;
Wang, C ;
Colyer, C ;
Harrison, J .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3036-3045
[9]   A micromachined chip-based electrospray source for mass spectrometry [J].
Licklider, L ;
Wang, XQ ;
Desai, A ;
Tai, YC ;
Lee, TD .
ANALYTICAL CHEMISTRY, 2000, 72 (02) :367-375
[10]   Micromachined ultrasonic droplet generator based on a liquid horn structure [J].
Meacham, JM ;
Ejimofor, C ;
Kumar, S ;
Degertekin, FL ;
Fedorov, AG .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05) :1347-1352