ULTRASONICALLY ASSISTED ELECTROSPRAY-IONIZATION FOR LC/MS DETERMINATION OF NUCLEOSIDES FROM A TRANSFER-RNA DIGEST

被引:98
作者
BANKS, JF [1 ]
SHEN, S [1 ]
WHITEHOUSE, CM [1 ]
FENN, JB [1 ]
机构
[1] YALE UNIV,DEPT CHEM ENGN,NEW HAVEN,CT 06520
关键词
D O I
10.1021/ac00075a015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of an ultrasonic nebulizer to assist electrospray ionization mass spectrometry (ESI-MS) has been described and demonstrated with the analysis of a transfer RNA digest by microcolumn LC. The restricted range of mobile-phase compositions amenable to the electrospray process has traditionally placed a severe limitation on the types of LC applications that can be used with ESI-MS. For this reason, an ultrasonic nebulizer configured for LC has been developed that can generate the fine dispersion of liquid required for ESI-MS from any type of mobile phase. In the case presented here, a transfer RNA was enzymatically digested into its substituent nucleosides, which were then analyzed by microcolumn LC. The required mobile-phase gradient (beginning at 5% methanol) falls outside the solvent range that can be used with conventional electrospray. The ultrasonic nebulizer, however, resolves this problem. The fundamental behavior of the four most common nucleosides (cytidine, adenosine, guanosine, uridine) was studied, and conclusions concerning the effects of solution chemistry were drawn. Specifically, signal from the H+ adducts of these species seems to be strongly dependent on the pK(a) value. Also, effects from several source operating variables were examined. These included capillary exit voltage, drying and focusing gases, and nebulizer frequency. Performance was found to be consistent over a wide range (0-100% methanol) of mobile-phase compositions. The limit of detection for adenosine injected onto a microcolumn was found to be 100 amol. Finally, nucleosides from as little as 150 fmol of RNA (amount prior to digestion) could be detected.
引用
收藏
页码:406 / 414
页数:9
相关论文
共 39 条
  • [1] MICROCOLUMN LIQUID-CHROMATOGRAPHY OF SMALL NUCLEIC-ACID CONSTITUENTS
    BANKS, JF
    NOVOTNY, MV
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 475 : 13 - 22
  • [2] BANKS JF, 1993, PITTSBURG C ATLANTA
  • [3] TIME-OF-FLIGHT MASS-SPECTROMETRY WITH AN ELECTROSPRAY ION-BEAM
    BOYLE, JG
    WHITEHOUSE, CM
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (18) : 2084 - 2089
  • [4] DETERMINATION OF SULFONATED AZO DYES BY LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY
    BRUINS, AP
    WEIDOLF, LOG
    HENION, JD
    BUDDE, WL
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (22) : 2647 - 2652
  • [5] ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY
    BRUINS, AP
    COVEY, TR
    HENION, JD
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (22) : 2642 - 2646
  • [6] ORIGIN AND REMOVAL OF ADDUCTS (MOLECULAR MASS = 98-U) ATTACHED TO PEPTIDE AND PROTEIN IONS IN ELECTROSPRAY IONIZATION MASS-SPECTRA
    CHOWDHURY, SK
    KATTA, V
    BEAVIS, RC
    CHAIT, BT
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1990, 1 (05) : 382 - 388
  • [7] MAJOR AND MODIFIED NUCLEOSIDES IN TRANSFER-RNA HYDROLYSATES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DAVIS, GE
    GEHRKE, CW
    KUO, KC
    AGRIS, PF
    [J]. JOURNAL OF CHROMATOGRAPHY, 1979, 173 (02): : 281 - 298
  • [8] DESIGN AND PERFORMANCE OF AN ELECTROSPRAY IONIZATION SOURCE FOR A DOUBLY-FOCUSING MAGNETIC-SECTOR MASS-SPECTROMETER
    GALLAGHER, RT
    CHAPMAN, JR
    MANN, M
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (10) : 369 - 372
  • [9] GEHRKA CW, 1982, J CHROMATOGR, V23, P297
  • [10] GEHRKA CW, 1983, MODIFIED NUCELOSIDES, P59