Temperature-dependent fluorescence lifetime of a fluorescent polymeric thermometer, Poly(N-isopropylacrylamide), labeled by polarity and hydrogen bonding sensitive 4-sulfamoyl-7-aminobenzofurazan
被引:95
作者:
Gota, Chie
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Pharmaceut Sci, Bunkyo Ku, Tokyo 1130033, JapanUniv Tokyo, Grad Sch Pharmaceut Sci, Bunkyo Ku, Tokyo 1130033, Japan
Gota, Chie
[1
]
Uchiyama, Seiichi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Pharmaceut Sci, Bunkyo Ku, Tokyo 1130033, JapanUniv Tokyo, Grad Sch Pharmaceut Sci, Bunkyo Ku, Tokyo 1130033, Japan
Uchiyama, Seiichi
[1
]
Yoshihara, Toshitada
论文数: 0引用数: 0
h-index: 0
机构:
Gunma Univ, Grad Sch Engn, Gunma 3768515, JapanUniv Tokyo, Grad Sch Pharmaceut Sci, Bunkyo Ku, Tokyo 1130033, Japan
Yoshihara, Toshitada
[2
]
Tobita, Seiji
论文数: 0引用数: 0
h-index: 0
机构:
Gunma Univ, Grad Sch Engn, Gunma 3768515, JapanUniv Tokyo, Grad Sch Pharmaceut Sci, Bunkyo Ku, Tokyo 1130033, Japan
Tobita, Seiji
[2
]
Ohwada, Tomohiko
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Pharmaceut Sci, Bunkyo Ku, Tokyo 1130033, JapanUniv Tokyo, Grad Sch Pharmaceut Sci, Bunkyo Ku, Tokyo 1130033, Japan
Ohwada, Tomohiko
[1
]
机构:
[1] Univ Tokyo, Grad Sch Pharmaceut Sci, Bunkyo Ku, Tokyo 1130033, Japan
[2] Gunma Univ, Grad Sch Engn, Gunma 3768515, Japan
Fluorescent molecular thermometers showing temperature-dependent fluorescence lifetimes enable thermal mapping of small spaces such as a microchannel and a living cell. We report the temperature-dependent fluorescence lifetimes of poly(NIPAM-co-DBD-AA), which is a random copolymer of N-isopropylacrylamide (NIPAM) and an environment-sensitive fluorescent monomer (DBD-AA) containing a 4-sulfamoyl-7-aminobenzofurazan structure. The average fluorescence lifetime of poly(NIPAM-co-DBD-AA) in aqueous solution increased from 4.22 to 14.1 ns with increasing temperature from 30 to 35 degrees C. This drastic change in fluorescence lifetime (27% increase per 1 degrees C) is the sharpest ever reported. Concentration independency, one of the advantages of fluorescence lifetime measurements, was seen in average fluorescence lifetime (13.7 +/- 0.18 ns) of poly(NIPAM-co-DBD-AA) at 33 degrees C over a wide concentration range (0.005-1 w/v%). With increasing temperature, polyNIPAM units in poly(NIPAM-co-DBD-AA) change their structure from an extended form to a globular form, providing apolar and aprotic environments to the fluorescent DBD-AA units. Consequently, the environment-sensitive DBD-AA units translate the local environmental changes into the extension of the fluorescence lifetime. This role of the DBD-AA units was revealed by a study of solvent effects on fluorescence lifetime of a model environment-sensitive fluorophore.