Extrapolated surface dose measurements with radiochromic film

被引:35
作者
Butson, MJ [1 ]
Yu, PKN
Metcalfe, PE
机构
[1] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon Tong, Peoples R China
[2] Illawarra Canc Care Ctr, Dept Med Phys, Wollongong, NSW 2500, Australia
关键词
radiochromic film; Gafchromic; surface dose; extrapolation method;
D O I
10.1118/1.598539
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A radiochromic film extrapolation method is described for the measurement of surface dose from high energy photon beams. Extrapolated central axis entrance surface dose using Gafchromic film for a 10 x 10 cm(2) field size is 15% +/- 2% and 13% +/- 2% of D-max for 6 and 10 MV x rays, respectively. Extrapolated surface dose for a 30 X 30 cm(2) field with a 10 mm perspex block tray is 49% +/- 2% and 48% +/- 2% of D-max for 6 and 10 MV beams, respectively. All results agree with uncorrected Attix parallel plate ionization chamber surface ionization within 4% for the same beam energies and configurations. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)01902-1].
引用
收藏
页码:485 / 488
页数:4
相关论文
共 16 条
[1]  
BUTSON M, IN PRESS PHYS MED BI
[2]  
Butson Martin J., 1996, Australasian Physical and Engineering Sciences in Medicine, V19, P74
[3]   Radiochromic film as a radiotherapy surface-dose detector [J].
Butson, MJ ;
Mathur, JN ;
Metcalfe, PE .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (06) :1073-1078
[4]  
CAROLAN M, 1997, AUST PHYS ENG SCI ME, V20
[5]   DOSE BUILDUP FOR OBLIQUELY INCIDENT PHOTON BEAMS [J].
GERBI, BJ ;
MEIGOONI, AS ;
KHAN, FM .
MEDICAL PHYSICS, 1987, 14 (03) :393-399
[6]   MEASUREMENT OF DOSE IN THE BUILDUP REGION USING FIXED-SEPARATION PLANE-PARALLEL IONIZATION CHAMBERS [J].
GERBI, BJ ;
KHAN, FM .
MEDICAL PHYSICS, 1990, 17 (01) :17-26
[7]   GafChromic MD-55: Investigated as a precision dosimeter [J].
Klassen, NV ;
van der Zwan, L ;
Cygler, J .
MEDICAL PHYSICS, 1997, 24 (12) :1924-1934
[8]   ENTRANCE AND EXIT DOSE REGIONS FOR A CLINAC-2100C [J].
KLEIN, EE ;
PURDY, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (02) :429-435
[9]   X-RAY SURFACE DOSE MEASUREMENTS USING TLD EXTRAPOLATION [J].
KRON, T ;
ELLIOT, A ;
WONG, T ;
SHOWELL, G ;
CLUBB, B ;
METCALFE, P .
MEDICAL PHYSICS, 1993, 20 (03) :703-711
[10]   SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS [J].
MCLAUGHLIN, WL ;
YUNDONG, C ;
SOARES, CG ;
MILLER, A ;
VANDYK, G ;
LEWIS, DF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) :165-176