Clinical dosimetry using MOSFETS

被引:130
作者
Ramani, R
Russell, S
OBrien, P
机构
[1] Division of Medical Physics, Toronto-Sunnybrook Regl. Cancer Ctr., North York, Ont.
[2] Division of Medical Physics, Toronto-Sunnybrook Regl. Cancer Ctr., North York, Ont. M4N 3M5
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1997年 / 37卷 / 04期
关键词
MOSFET; clinical dosimetry; TLD;
D O I
10.1016/S0360-3016(96)00600-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The use of metal oxide-silicon field effect transistors (MOSFETs) as clinical dosimeters is demonstrated for a number of patients with targets at different clinical sites. Methods and Materials: Commercially available MOSFETs were characterized for energy response, angular dependency of response, and effect of accumulated dose on sensitivity and some inherent properties of MOSFETs. The doses determined both by thermoluminescence dosimetry (TLD) and MOSFETs in clinical situation were evaluated and compared to expected doses determined by calculation, Results: It was observed that a standard calibration of 0.01 Gy/mV gave MOSFET determined doses which agreed with expected doses to within 5% at the 95% confidence limit for photon beams from 6 to 25 MV and electron beams from 5 to 14 MeV. An energy-dependent variation in response of up to 28% was observed between two orientations of a MOSFET, The MOSFET doses compared very well with the doses estimated by TLDs, and the patients tolerated MOSFETs very well, A standard deviation of 3.9% between expected dose and MOSFET determined dose was observed, while for TLDs the standard deviation was 5.1%. The advantages and disadvantages of using MOSFETs for clinical dosimetry are discussed in detail, Conclusion: It was concluded that MOSFETs can be used as clinical dosimeters and can be a good alternative to TLDs, However, they have limitations under certain clinical situations, (C) 1997 Elsevier Science Inc.
引用
收藏
页码:959 / 964
页数:6
相关论文
共 11 条
[1]  
CYGLER J, 1995, MED PHYS, V22, P1541
[2]   THERMOLUMINESCENT CHARACTERISTICS OF LIFMG, TI FROM 3 MANUFACTURERS [J].
FAIRBANKS, EJ ;
DEWERD, LA .
MEDICAL PHYSICS, 1993, 20 (03) :729-731
[3]   AUTOMATED DATA-COLLECTION AND ANALYSIS SYSTEM FOR MOSFET RADIATION DETECTORS [J].
GLADSTONE, DJ ;
CHIN, LM .
MEDICAL PHYSICS, 1991, 18 (03) :542-548
[4]   MINIATURE RADIATION DOSIMETER FOR INVIVO RADIATION MEASUREMENTS [J].
HUGHES, RC ;
HUFFMAN, D ;
SNELLING, JV ;
ZIPPERIAN, TE ;
RICCO, AJ ;
KELSEY, CA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (05) :963-967
[5]  
Kron Tomas, 1993, Australasian Physical and Engineering Sciences in Medicine, V16, P137
[6]  
McGhee P, 1993, Med Dosim, V18, P187
[7]   A QA PHANTOM FOR DYNAMIC STEREOTAXIC RADIOSURGERY - QUANTITATIVE MEASUREMENTS [J].
RAMANI, R ;
KETKO, MG ;
OBRIEN, PF ;
SCHWARTZ, ML .
MEDICAL PHYSICS, 1995, 22 (08) :1343-1346
[8]   EVALUATION OF A DUAL BIAS DUAL METAL-OXIDE-SILICON SEMICONDUCTOR FIELD-EFFECT TRANSISTOR DETECTOR AS RADIATION DOSIMETER [J].
SOUBRA, M ;
CYGLER, J ;
MACKAY, G .
MEDICAL PHYSICS, 1994, 21 (04) :567-572
[9]  
SPENDER M, COMMUNICATION
[10]   FACTORS AFFECTING THE PRECISION OF TLD DOSE MEASUREMENTS USING AN AUTOMATIC TLD READER [J].
WOOD, JJ ;
MAYLES, WPM .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (02) :309-313