A QA PHANTOM FOR DYNAMIC STEREOTAXIC RADIOSURGERY - QUANTITATIVE MEASUREMENTS

被引:23
作者
RAMANI, R
KETKO, MG
OBRIEN, PF
SCHWARTZ, ML
机构
[1] Division of Medical Physics, Toronto—Sunnybrook Regional Cancer Centre, North York, Ont M4N 3M5
关键词
QUALITY ASSURANCE PHANTOM; ERROR MEASUREMENTS; DYNAMIC RADIOSURGERY;
D O I
10.1118/1.597518
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A spherical acrylic phantom was designed for quality assurance measurements of dynamic radiosurgery. The phantom consists of two mating hemispheres mounted on a base plate. The interhemispheric plane may be oriented at any angle to the base, the angle being identified by visible marks on the base plate of the phantom. The phantom has a set of replaceable, radiologically identifiable markers, suitable for Computed Tomography (CT), Magnetic Resonance (MR), and Digital Subtraction Angiography (DSA) imaging. The frame coordinates of each marker are calculated from its known positions with respect to the center of the sphere. The measured errors of these positions using CT and MR images, were within the voxel size of the displayed image, while for DSA images the error was greater than 2.5 mm at the periphery of the image. The calculated depths from the planning software, for various beam intersection points to the isocenter, agreed within 0.6 mm with the known depths. A variation of 3.6+/-2.6 mm in the calculated depths was observed between using MR and CT image data. This difference results in a 1% variation in Tissue Maximum Ratio (TMR) calculations. Comparisons of measured and known volumes resulted in differences of 8%-10%.
引用
收藏
页码:1343 / 1346
页数:4
相关论文
共 8 条
[1]  
DAVEY P, 1993, MAY INT C COURS STER
[2]   A SIMPLE TEST PHANTOM FOR STEREOTAXIC COMPUTED-TOMOGRAPHY [J].
EKSTRAND, KE ;
OLDS, WW ;
BRANCH, CL .
MEDICAL PHYSICS, 1993, 20 (02) :391-393
[3]   RADIOSURGERY WITH UNFLATTENED 6-MV PHOTON BEAMS [J].
OBRIEN, PF ;
GILLIES, BA ;
SCHWARTZ, M ;
YOUNG, C ;
DAVEY, P .
MEDICAL PHYSICS, 1991, 18 (03) :519-521
[4]   DYNAMIC STEREOTACTIC RADIOSURGERY [J].
PODGORSAK, EB ;
OLIVIER, A ;
PLA, M ;
LEFEBVRE, PY ;
HAZEL, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (01) :115-126
[5]   RADIOSURGERY WITH PHOTON BEAMS - PHYSICAL ASPECTS AND ADEQUACY OF LINEAR ACCELERATORS [J].
PODGORSAK, EB ;
PIKE, GB ;
PLA, M ;
OLIVIER, A ;
SOUHAMI, L .
RADIOTHERAPY AND ONCOLOGY, 1990, 17 (04) :349-358
[6]  
SERAGO CF, 1991, 32ND ANN M ASTRO WAS
[7]   QUALITY ASSURANCE IN STEREOTAXIC RADIOSURGERY USING A STANDARD LINEAR-ACCELERATOR [J].
TSAI, JS ;
BUCK, BA ;
SVENSSON, GK ;
ALEXANDER, E ;
CHENG, CW ;
MANNARINO, EG ;
LOEFFLER, JS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (03) :737-748
[8]   SYSTEMATIC ANALYSIS OF ERRORS IN TARGET LOCALIZATION AND TREATMENT DELIVERY IN STEREOTAXIC RADIOSURGERY (SRS) [J].
YEUNG, D ;
PALTA, J ;
FONTANESI, J ;
KUN, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (02) :493-498