Gastric emptying characteristics of a novel 13C-octanoate-labeled muffin meal

被引:27
作者
Chey, WD
Shapiro, B
Zawadski, A
Goodman, K
机构
[1] Univ Michigan, Med Ctr, Dept Gastroenterol,Div Gastroenterol, Taubman Ctr 3912, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Med Ctr, Div Nucl Med, Ann Arbor, MI 48109 USA
[3] Metab Solut Inc, Nashua, NH USA
关键词
gastric emptying; scintigraphy; octanoate; breath tests;
D O I
10.1097/00004836-200105000-00007
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Goals: Determine the gastric emptying characteristics of a novel, 350-kcal test meal consisting of two muffins, using scintigraphy and the C-13-octanoate breath test OBT. Study: Healthy volunteers underwent three studies on separate days within a 1-week period. On day 1, we measured emptying of the 350-kcal muffin test meal lab;led simultaneously with Tc-99m sulfur colloid and C-13-octanoate. On day 2, reproducibility of the OBT using a single-labeled 350-kcal test meal was assessed. On day 3, the effect of erythromycin on the 350-kcal OBT was determined. Results: The mean (+/- SD) half-emptying time (T1/2) as measured by scintigraphy was 104 +/- 24 minutes, versus 212 +/- 52 minutes by OBT, There was a strong correlation between T1/2 determined by scintigraphy rind the breath test (r = 0.83). Multiple linear regression analysis identified a significant relationship between T1/2 determined by scintigraphy and the 90- and 180-minute breath samples. There was a strong correlation (r = 0.830), slope = 0.732 +/- 0.120 [SE], intercept = 26.4 +/- 12.7) between the T1/2 obtained using the regression equation and the actual T1/2 obtained by scintigraphy. The mean T1/2 (+/- SD) for replicate determinations using the OBT was 209 +/- 52 minutes, compared with 196 +/- 42 minutes on days 1 and 2. respectively (not significant, p = 0.28, paired Student t test. Treatment with erythromycin on day 3 produced a significant decrease in T1/2 (155 +/- 49 minutes, p = 0.002). Conclusions: The 350-kcal muffin meal OBT provides a convenient, nonscintigaphic way of measuring solid-phase gastric emptying. Multiple linear regression appears promising as a method of analyzing OBT data and may allow for an abbreviated breath test protocol.
引用
收藏
页码:394 / 399
页数:6
相关论文
共 27 条
[1]   Reproducibility of the 13C-octanoic acid breath test for assessment of gastric emptying in healthy preterm infants [J].
Barnett, C ;
Snel, A ;
Omari, T ;
Davidson, G ;
Haslam, R ;
Butler, R .
JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1999, 29 (01) :26-30
[2]   VARIABILITY OF GASTRIC-EMPTYING MEASUREMENTS IN MAN EMPLOYING STANDARDIZED RADIOLABELED MEALS [J].
BROPHY, CM ;
MOORE, JG ;
CHRISTIAN, PE ;
EGGER, MJ ;
TAYLOR, AT .
DIGESTIVE DISEASES AND SCIENCES, 1986, 31 (08) :799-806
[3]   [C-13]octanoic acid breath test for gastric emptying of solids: Accuracy, reproducibility, and comparison with scintigraphy [J].
Choi, MG ;
Camilleri, M ;
Burton, DD ;
Zinsmeister, AR ;
Forstrom, LA ;
Nair, KS .
GASTROENTEROLOGY, 1997, 112 (04) :1155-1162
[4]   Reproducibility and simplification of 13C-octanoic acid breath test for gastric emptying of solids [J].
Choi, MG ;
Camilleri, M ;
Burton, DD ;
Zinsmeister, AR ;
Forstrom, LA ;
Nair, KS .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 1998, 93 (01) :92-98
[5]  
CHRISTIAN PE, 1991, J NUCL MED, V32, P1349
[7]   INFLUENCE OF CISAPRIDE ON GASTRIC-EMPTYING OF SOLIDS AND LIQUIDS MONITORED BY C-13 BREATH TESTS [J].
DUAN, LP ;
BRADEN, B ;
CASPARY, WF ;
LEMBCKE, B .
DIGESTIVE DISEASES AND SCIENCES, 1995, 40 (10) :2200-2206
[8]  
Ehrenpreis ED, 1996, AM J GASTROENTEROL, V91, P674
[9]  
ELASHOFF JD, 1982, GASTROENTEROLOGY, V83, P1306
[10]   MEASUREMENT OF GASTRIC-EMPTYING RATE OF SOLIDS BY MEANS OF A CARBON-LABELED OCTANOIC-ACID BREATH TEST [J].
GHOOS, YF ;
MAES, BD ;
GEYPENS, BJ ;
MYS, G ;
HIELE, MI ;
RUTGEERTS, PJ ;
VANTRAPPEN, G .
GASTROENTEROLOGY, 1993, 104 (06) :1640-1647