Poly(ethylene glycol): Protein-repulsive or albumin-compatible?

被引:65
作者
Vert, M [1 ]
Domurado, D [1 ]
机构
[1] Univ Montpellier I, Fac Pharm, CNRS, UMR 5473,Ctr Rech Biopolymeres Artificiels, F-34060 Montpellier 2, France
关键词
PEO/PEG; protein; albumin; synthetic-polymer/protein interaction; long time plasma circulation; stealth effect;
D O I
10.1163/156856200744345
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the literature, many papers deal with the behavior of proteins in aqueous media in the presence of poly(ethylene glycol) (PEG) molecules or poly(ethylene oxide) (PEO) segments, physically adsorbed onto, or covalently attached to, macromolecules or to solid surfaces. In particular, it is well known that PEO segments make foreign materials stealthy, i.e. they are much less detected by the immune system either through humoral reactions or, at the cell level, through opsonins. Revisiting the literature led us to challenge the largely accepted opinion that the decreased recognition of PEO segment-bearing foreign macromolecules and particles by the mononuclear phagocyte system is primarily the consequence of the repulsion of all blood proteins by PEG segments through the excluded volume effect. This challenge is based on the finding that albumin and PEG are compatible in phosphate-buffered saline at room temperature and at concentrations comparable to those measured by others on the surface of PEO segment-bearing species, whereas fibrinogen and PEG phase-separated and were incompatible despite the much lower concentration of the latter protein. According to literature and to these observations, it is proposed that the stealth effect induced by PEO segments is primarily due to the compatibility between PEO segments of intermediate molar mass and albumin, thus rendering PEG-bearing macromolecules or surfaces to look like native albumin. Under such conditions, the hospitality offend by PEG macromolecules or PEO segments to albumin, the dominant plasma protein, results in a 'chameleon' effect that prevents the activation of other PEG-compatible or -incompatible plasma proteins or cells involved in foreign body recognition and elimination. PEG with molar masses greater than or equal to 8000 did not accommodate albumin in agreement with the excluded volume phenomenon.
引用
收藏
页码:1307 / 1317
页数:11
相关论文
共 51 条
[31]  
KIDANE A, 1997, POLYM MAT SCI ENG, V77, P570
[32]   COMPLEXATION OF PEPSIN POLY(ETHYLENE GLYCOL) [J].
KOKUFUTA, E ;
NISHIMURA, H .
POLYMER BULLETIN, 1991, 26 (03) :277-282
[33]  
LEE JC, 1981, J BIOL CHEM, V256, P625
[34]   Controlled release of interleukin-2 for tumour immunotherapy using alginate/chitosan porous microspheres [J].
Liu, LS ;
Liu, SQ ;
Ng, SY ;
Froix, M ;
Ohno, T ;
Heller, J .
JOURNAL OF CONTROLLED RELEASE, 1997, 43 (01) :65-74
[35]   Plasma protein adsorption on biodegradable microspheres consisting of poly(D,L-lactide-co-glycolide), poly(L-lactide) or ABA triblock copolymers containing poly(oxyethylene) - Influence of production method and polymer composition [J].
Luck, M ;
Pistel, KF ;
Li, YX ;
Blunk, T ;
Muller, RH ;
Kissel, T .
JOURNAL OF CONTROLLED RELEASE, 1998, 55 (2-3) :107-120
[36]  
LYMAN DJ, 1968, T AM SOC ART INT ORG, V14, P250
[37]   Microstructure and release characteristics of the minipellet, a collagen-based drug delivery system for controlled release of protein drugs [J].
Maeda, M ;
Tani, S ;
Sano, A ;
Fujioka, K .
JOURNAL OF CONTROLLED RELEASE, 1999, 62 (03) :313-324
[38]  
McPherson A Jr, 1976, Methods Biochem Anal, V23, P249, DOI 10.1002/9780470110430.ch4
[39]   Prevention of protein adsorption by tethered poly(ethylene oxide) layers: Experiments and single-chain mean-field analysis [J].
McPherson, T ;
Kidane, A ;
Szleifer, I ;
Park, K .
LANGMUIR, 1998, 14 (01) :176-186
[40]  
MOLINA I, 2000, IN PRESS BIOMATERIAL