High-resolution tomographic imaging of a human cerebellum: comparison of absorption and grating-based phase contrast

被引:111
作者
Schulz, Georg [1 ]
Weitkamp, Timm [2 ]
Zanette, Irene [2 ]
Pfeiffer, Franz [3 ]
Beckmann, Felix [4 ]
David, Christian [5 ]
Rutishauser, Simon [5 ]
Reznikova, Elena [6 ]
Mueller, Bert [1 ]
机构
[1] Univ Basel, Biomat Sci Ctr, Basel, Switzerland
[2] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[3] Tech Univ Munich, Dept Phys Biophys E17, D-8046 Garching, Germany
[4] GKSS Forschungszentrum Geesthacht GmbH, Inst Mat Res, Geesthacht, Germany
[5] Paul Scherrer Inst, Lab Micro & Nanotechnol, Villigen, Switzerland
[6] Karlsruhe Inst Technol, Inst Microstruct Technol, Karlsruhe, Germany
基金
瑞士国家科学基金会;
关键词
synchrotron radiation-based microtomography; absorption contrast; X-ray phase contrast; X-ray grating interferometry; X-ray Talbot interferometry; human brain tissue; NONDESTRUCTIVE 3-DIMENSIONAL EVALUATION; MICRO-COMPUTED-TOMOGRAPHY; RAY TALBOT INTERFEROMETRY; PURKINJE-CELL SIZE; SYNCHROTRON-RADIATION; SMALL SAMPLES; X-RAYS; IMAGES; BRAIN; HOLOTOMOGRAPHY;
D O I
10.1098/rsif.2010.0281
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Human brain tissue belongs to the most impressive and delicate three-dimensional structures in nature. Its outstanding functional importance in the organism implies a strong need for brain imaging modalities. Although magnetic resonance imaging provides deep insights, its spatial resolution is insufficient to study the structure on the level of individual cells. Therefore, our knowledge of brain microstructure currently relies on two-dimensional techniques, optical and electron microscopy, which generally require severe preparation procedures including sectioning and staining. X-ray absorption microtomography yields the necessary spatial resolution, but since the composition of the different types of brain tissue is similar, the images show only marginal contrast. An alternative to absorption could be X-ray phase contrast, which is known for much better discrimination of soft tissues but requires more intricate machinery. In the present communication, we report an evaluation of the recently developed X-ray grating interferometry technique, applied to obtain phase-contrast as well as absorption-contrast synchrotron radiation-based microtomography of human cerebellum. The results are quantitatively compared with synchrotron radiation-based microtomography in optimized absorption-contrast mode. It is demonstrated that grating interferometry allows identifying besides the blood vessels, the stratum moleculare, the stratum granulosum and the white matter. Along the periphery of the stratum granulosum, we have detected microstructures about 40 mm in diameter, which we associate with the Purkinje cells because of their location, size, shape and density. The detection of individual Purkinje cells without the application of any stain or contrast agent is unique in the field of computed tomography and sets new standards in non-destructive three-dimensional imaging.
引用
收藏
页码:1665 / 1676
页数:12
相关论文
共 51 条
[31]   PHASE-CONTRAST RADIOGRAPHS OF NONSTAINED RAT CEREBELLAR SPECIMEN [J].
MOMOSE, A ;
FUKUDA, J .
MEDICAL PHYSICS, 1995, 22 (04) :375-379
[32]   Phase tomography by X-ray Talbot interferometry for biological imaging [J].
Momose, Atsushi ;
Yashiro, Wataru ;
Takeda, Yoshihiro ;
Suzuki, Yoshio ;
Hattori, Tadashi .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (6A) :5254-5262
[33]   Morphology of bony tissues and implants uncovered by high-resolution tomographic imaging [J].
Mueller, Bert ;
Bernhardth, Ricardo ;
Weitkamp, Timm ;
Beckmann, Felix ;
Braeuere, Rolf ;
Schurigt, Uta ;
Schrott-Fischer, Annelies ;
Glueckert, Rudolf ;
Ney, Michael ;
Beleites, Thomas ;
Jolly, Claude ;
Schamweber, Dieter .
INTERNATIONAL JOURNAL OF MATERIALS RESEARCH, 2007, 98 (07) :613-621
[34]   Non-destructive three-dimensional evaluation of a polymer sponge by micro-tomography using synchrotron radiation [J].
Müller, B ;
Beckmann, F ;
Huser, M ;
Maspero, F ;
Székely, G ;
Ruffieux, K ;
Thurner, P ;
Wintermantel, E .
BIOMOLECULAR ENGINEERING, 2002, 19 (2-6) :73-78
[35]   Non-destructive three-dimensional evaluation of biocompatible materials by microtomography using synchrotron radiation [J].
Müller, B ;
Thurner, P ;
Beckmann, F ;
Weitkamp, T ;
Rau, C ;
Bernhardt, R ;
Karamuk, E ;
Eckert, L ;
Brandt, J ;
Buchloh, S ;
Wintermantel, E ;
Scharnweber, D ;
Worch, H .
DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 :178-188
[36]   High-resolution brain tumor visualization using three-dimensional x-ray phase contrast tomography [J].
Pfeiffer, F. ;
Bunk, O. ;
David, C. ;
Bech, M. ;
Le Duc, G. ;
Bravin, A. ;
Cloetens, P. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (23) :6923-6930
[37]   Tomographic reconstruction of three-dimensional objects from hard X-ray differential phase contrast projection images [J].
Pfeiffer, F. ;
Bunk, O. ;
Kottler, C. ;
David, C. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02) :925-928
[38]   Hard X-ray phase tomography with low-brilliance sources [J].
Pfeiffer, F. ;
Kottler, C. ;
Bunk, O. ;
David, C. .
PHYSICAL REVIEW LETTERS, 2007, 98 (10)
[39]   High-sensitivity phase-contrast tomography of rat brain in phosphate buffered saline [J].
Pfeiffer, Franz ;
David, Christian ;
Bunk, Oliver ;
Poitry-Yamate, Carole ;
Gruetter, Rolf ;
Mueller, Bert ;
Weitkamp, Timm .
9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186
[40]   Skull and brain of a 300-million-year-old chimaeroid fish revealed by synchrotron holotomography [J].
Pradel, Alan ;
Langer, Max ;
Maisey, John G. ;
Geffard-Kuriyama, Didier ;
Cloetens, Peter ;
Janvier, Philippe ;
Tafforeau, Paul .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2009, 106 (13) :5224-5228