Simultaneous determination of acetylcholine, choline and physostigmine in microdialysis samples from rat hippocampus by microbore liquid chromatography electrochemistry on peroxidase redox polymer coated electrodes

被引:38
作者
Kehr, J
Dechent, P
Kato, T
Ögren, SO
机构
[1] Karolinska Inst, Dept Neurosci, S-17177 Stockholm, Sweden
[2] Yokohama City Univ, Lab Mol Recognit, Yokohama, Kanagawa, Japan
关键词
acetylcholine; butyrylcholine; choline derivatives; internal standardization; on-line monitoring; electrochemical detection;
D O I
10.1016/S0165-0270(98)00074-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microbore column liquid chromatography with post-column immobilized enzyme reactor (IMER) and electrochemical detection on redox polymer coated electrodes was used for detection of acetylcholine (ACh) and choline (Ch) in microdialysis samples. The sensitivity of the coated electrodes, decreased gradually by about 10%/day, with highest reduction of 30% within the first 16 h of use. A number of choline derivatives were tested as possible internal standards, of those acetylethylhomocholine (AEHCh) and butyrylcholine (BCh) were found the most suitable candidates since they both provided high enzymatic conversion in the IMER. Physostigmine produced a negative peak, possibly reflecting oxidation of eseroline-a decarbamoylated product of reversible reaction of physostigmine with immobilized acetylcholine esterase. The probes, implanted in the ventral hippocampi of awake rats were perfused at a flow-rate of 1.25 mu l/min with Ringer solution containing 10 mu M physostigmine or with artificial cerebrospinal fluid only. The concentrations of ACh in 10-mu l samples at basal conditions were between 0.9-2.5 nM, whereas in the presence of physostigmine the ACh levels raised to 41-48 nM. Physostigmine concentration was reduced to 8.8 mu M, indicating its in vivo delivery of about 12%. The coefficients of variation were reduced from 7.4% for external standard method after every sixth sample to 5.8% and 5.9% for internal standardization with AEHCh and BCh, respectively. The latter method shortened the total analysis time by about 15%, thus being especially suitable for continuous long-lasting off-line or on-line monitoring. Additionally, other endogenous cholines such as butyrylcholine or synthetic choline derivatives could be detected by the present method. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 23 条
[1]   BRAIN DIALYSIS - DETECTION OF ACETYLCHOLINE IN THE STRIATUM OF UNRESTRAINED AND UNANESTHETIZED RATS [J].
AJIMA, A ;
KATO, T .
NEUROSCIENCE LETTERS, 1987, 81 (1-2) :129-132
[2]   Microbore high-performance liquid chromatographic method for measuring acetylcholine in microdialysis samples: Optimizing performance of platinum electrodes [J].
Carter, AJ ;
Kehr, J .
JOURNAL OF CHROMATOGRAPHY B, 1997, 692 (01) :207-212
[3]   A SIMPLE, SENSITIVE, AND ECONOMIC ASSAY FOR CHOLINE AND ACETYLCHOLINE USING HPLC, AND ENZYME REACTOR, AND AN ELECTROCHEMICAL DETECTOR [J].
DAMSMA, G ;
WESTERINK, BHC ;
HORN, AS .
JOURNAL OF NEUROCHEMISTRY, 1985, 45 (05) :1649-1652
[4]   MEASUREMENT OF ACETYLCHOLINE-RELEASE IN FREELY MOVING RATS BY MEANS OF AUTOMATED INTRACEREBRAL DIALYSIS [J].
DAMSMA, G ;
WESTERINK, BHC ;
DEVRIES, JB ;
VANDENBERG, CJ ;
HORN, AS .
JOURNAL OF NEUROCHEMISTRY, 1987, 48 (05) :1523-1528
[5]   ACETYLCHOLINE MEASUREMENT BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AN ENZYME-LOADED POSTCOLUMN REACTOR [J].
EVA, C ;
HADJICONSTANTINOU, M ;
NEFF, NH ;
MEEK, JL .
ANALYTICAL BIOCHEMISTRY, 1984, 143 (02) :320-324
[6]   DETERMINATION OF ACETYLCHOLINE AND CHOLINE IN PERCHLORATE EXTRACTS OF BRAIN-TISSUE USING LIQUID-CHROMATOGRAPHY ELECTROCHEMISTRY WITH AN IMMOBILIZED-ENZYME REACTOR [J].
FUJIMORI, K ;
YAMAMOTO, K .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 414 (01) :167-173
[7]  
HUANG TH, 1995, J CHROMATOGR B, V670, P323
[8]   METABOLISM OF PHYSOSTIGMINE IN MOUSE-LIVER MICROSOMAL INCUBATIONS STUDIED BY LIQUID-CHROMATOGRAPHY WITH DUAL-ELECTRODE AMPEROMETRIC DETECTION [J].
ISAKSSON, K ;
KISSINGER, PT .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 419 :165-175
[9]   Detection of basal acetylcholine release in the microdialysis of rat frontal cortex by high-performance liquid chromatography using a horseradish peroxidase-osmium redox polymer electrode with pre-enzyme reactor [J].
Kato, T ;
Liu, JK ;
Yamamoto, K ;
Osborne, PG ;
Niwa, O .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1996, 682 (01) :162-166
[10]  
KEHR J, 1996, MONITORING MOL NEURO, P27