Conducting polymers with benzothiadiazole and benzoselenadiazole units for biosensor applications

被引:37
作者
Emre, Fatma Bilge [2 ,3 ]
Ekiz, Fulya [4 ]
Balan, Abidin [2 ,5 ]
Emre, Sinan [6 ]
Timur, Suna [1 ]
Toppare, Levent [2 ,4 ,7 ]
机构
[1] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Izmir, Turkey
[2] Middle E Tech Univ, Dept Chem, TR-06531 Ankara, Turkey
[3] Inonu Univ, Fac Educ, TR-44280 Malatya, Turkey
[4] Middle E Tech Univ, Dept Biotechnol, TR-06531 Ankara, Turkey
[5] Eindhoven Univ Technol, Dept Chem Engn & Chem, Lab Macromol & Organ Chem, NL-5600 MB Eindhoven, Netherlands
[6] Celal Bayar Univ, Dept Ophthalmol, Fac Med, TR-45010 Manisa, Turkey
[7] Middle E Tech Univ, Dept Polymer Sci & Technol, TR-06531 Ankara, Turkey
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2011年 / 158卷 / 01期
关键词
Enzyme immobilization; Conducting polymer; Biosensor; Surface modification; AMPEROMETRIC GLUCOSE BIOSENSOR; PI-STACKING INTERACTIONS; 7-METHYLGUANINE BASE; NEUTRAL STATE; IMMOBILIZATION; OXIDASE; FILM;
D O I
10.1016/j.snb.2011.05.052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Poly(4,7-di(2,3)-dihydrothienol[3,4-b][1,4]dioxin-5-yl-benzo[1,2,5]thiadiazole) (PBDT) and poly(4,7-di(2,3)-dihydrothienol[3,4-b][1,4]dioxin-5-yl-2,1,3-benzoselenadiazole) (PESeE) were electrochemically deposited on graphite electrodes and used as immobilization matrices for biosensing studies. After electrochemical deposition of the polymeric matrices, glucose oxidase (GOx) was immobilized on the modified electrodes as the model enzyme. In the biosensing studies, the decrease in oxygen level as a result of enzymatic reaction was monitored at -0.7 V vs Ag/AgCl (3.0 M KCl) and correlated with substrate concentration. The biosensor was characterized in terms of several parameters such as operational and storage stabilities, kinetic parameters (K-m and I-max) and surface morphologies. The biosensor was tested on real human blood serum samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 46 条
[41]   Amperometric bienzyme glucose biosensor based on carbon nanotube modified electrode with electropolymerized poly(toluidine blue O) film [J].
Wang, Wenju ;
Wang, Fang ;
Yao, Yanli ;
Hu, Shengshui ;
Shiu, Kwok-Keung .
ELECTROCHIMICA ACTA, 2010, 55 (23) :7055-7060
[42]   Improved enzyme immobilization for enhanced bioelectrocatalytic activity of glucose sensor [J].
Wang, Yi-Ting ;
Yu, Lei ;
Zhu, Zi-Qiang ;
Zhang, Jian ;
Zhu, Jian-Zhong ;
Fan, Chun-hai .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 136 (02) :332-337
[43]   Enzymatic glucose biosensor based on ZnO nanorod array grown by hydrothermal decomposition [J].
Wei, A. ;
Sun, X. W. ;
Wang, J. X. ;
Lei, Y. ;
Cai, X. P. ;
Li, C. M. ;
Dong, Z. L. ;
Huang, W. .
APPLIED PHYSICS LETTERS, 2006, 89 (12)
[44]   Conducting polymer nanostructures and their application in biosensors [J].
Xia, Lin ;
Wei, Zhixiang ;
Wan, Meixiang .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2010, 341 (01) :1-11
[45]   Theoretical study on electronic structure and optical properties of novel donor-acceptor conjugated copolymers derived from benzothiadiazole and benzoselenadiazole [J].
Yang, Li ;
Feng, Ji-Kang ;
Ren, Al-Min .
JOURNAL OF MOLECULAR STRUCTURE-THEOCHEM, 2007, 816 (1-3) :161-170
[46]   Palladium nanoparticle/chitosan-grafted graphene nanocomposites for construction of a glucose biosensor [J].
Zeng, Qiong ;
Cheng, Jin-Sheng ;
Liu, Xiao-Fei ;
Bai, Hao-Tian ;
Jiang, Jian-Hui .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (08) :3456-3463