Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis

被引:79
作者
Zhang, M
Turner-Smith, AR
Tanner, A
Roberts, VC
机构
[1] Kings Coll London, Sch Med & Dent, Dept Med Engn & Phys, London SE5 9RS, England
[2] Blatchfords Ltd, Kings Healthcare Rehabil Ctr, London, England
关键词
amputation; biomechanics; pressure; shear stress; prothesis;
D O I
10.1016/S1350-4533(98)00013-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A system for measuring pressures and bi-axial shear stresses at the body support interfaces has been developed. This system has been used, in five unilateral trans-tibial amputees, to investigate the stresses at multiple points on the residual limb and prosthetic socket interface during standing and walking. The subjects investigated regularly used a patellar-tendon-bearing socket. The maximum peak pressure at the measured points was 320 kPa over the popliteal area during walking. The maximum shear stress was 61 kPa over the medial tibia area. Variable wave-forms of stress during walking were observed at the different measured points. The influence of the angular alignment on the stresses was investigated on one subject. It was found that a miss-alignment of +/- 8 degrees produced a change in peak longitudinal shear stress of between 8% and 11.5%. (C) 1998 IPEM. Published by Elsevier Science Ltd.
引用
收藏
页码:188 / 198
页数:11
相关论文
共 21 条
[1]  
Appoldt F., 1968, B PROSTHET RES FAL, P106
[2]  
Burgess E M, 1977, Bull Prosthet Res, P58
[3]  
ISHERWOOD PA, 1978, SIMULTANEOUS PTB SOC, P45
[4]  
LEE VSP, P I MECH E H, V211, P167
[5]  
LORD M, 1984, PROSTHET ORTHOT INT, V8, P159
[6]  
McColl I, 1986, REV ARTIFICIAL LIMB
[7]  
Pearson J R, 1973, Bull Prosthet Res, V10, P52
[8]   ANALYSIS OF A BELOW-KNEE PATELLAR TENDON-BEARING PROSTHESIS - A FINITE-ELEMENT STUDY [J].
QUESADA, P ;
SKINNER, HB .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1991, 28 (03) :1-12
[9]  
RAE JW, 1971, B PROSTHET RES, P64
[10]   INTERFACE LOAD ANALYSIS FOR COMPUTER-AIDED-DESIGN OF BELOW-KNEE PROSTHETIC SOCKETS [J].
REYNOLDS, DP ;
LORD, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (04) :419-426