Detection of ventricular fibrillation in implantable defibrillators with automatic gain control amplifiers - Effects of programming sensitivity

被引:5
作者
Schulte, B
Sperzel, J
Schwarz, T
Pitschner, HF
Strupp, G
Neuzner, J
机构
[1] Kerckhoff Clin, Dept Cardiol, D-61231 Bad Nauheim, Germany
[2] Med Clin 1, Fulda, Germany
来源
EUROPACE | 2000年 / 2卷 / 02期
关键词
implantable defibrillator; automatic gain control; programmable sensitivity;
D O I
10.1053/eupc.1999.0083
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims In newer implantable cardioverter-defibrillators with automatic gain control amplifiers the maximum possible sensitivity is programmed with the aim of securing optimal detection of ventricular fibrillation. This study was designed to prove that a reduction in maximum sensitivity is safe with respect to appropriate sensing of ventricular fibrillation, while avoiding sensing of extracardiac signals. Methods and Results Forty-two consecutive patients, undergoing defibrillator implantation/replacement with programmable maximum auto-gain sensing sensitivity (Ventak Mini III(TM). Ventak AV(TM), Guidant, St. Paul, MN, U.S.A.), were prospectively investigated. Thirty-four patients were implanted with a dual-coil lead system, providing integrated bipolar sensing (Endotak(TM), Guidant, St. Paul, MN, U.S.A.), eight patients received a single-coil lead system with true bipolar sensing (Sprint(TM), Medtronic, Minneapolis, MN, U.S.A.). During device implantation and pre-discharge testing, arrhythmia detection times of induced ventricular fibrillation were compared at programmed maximum (0.18 mV) and minimum (0.43 mV) sensitivity in a randomized manner. Seventy-six induced episodes of ventricular fibrillation were analysed. The mean arrhythmia detection times did not differ between the programmed sensing levels (maximum sensitivity: 1612+/-307 ms. vs minimal sensitivity: 1602+/-330 ms; P=ns). The results were not affected by the type of implanted lead system (integrated bipolar versus true bipolar sensing). Conclusion In the implantable defibrillator devices, reduction in maximum sensitivity did not impair the detection of induced episodes of ventricular fibrillation. (Europace 2000; 2: 160-162) (C) 2000 The European Society of Cardiology.
引用
收藏
页码:160 / 162
页数:3
相关论文
共 12 条
[1]   INHIBITION OF BIPOLAR DEMAND PACEMAKER BY DIAPHRAGMATIC MYOPOTENTIALS [J].
BAROLD, SS ;
ONG, LS ;
FALKOFF, MD ;
HEINLE, RA .
CIRCULATION, 1977, 56 (04) :679-683
[2]  
BRUMWELL DA, IMPLANTABLE CARDIOVE, P275
[3]   UNIQUE SENSING ERRORS IN 3RD-GENERATION IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS [J].
CALLANS, DJ ;
HOOK, BG ;
KLEIMAN, RB ;
MITRA, RL ;
FLORES, BT ;
MARCHLINSKI, FE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) :1135-1140
[4]   Myopotential sensing by a dual chamber implantable cardioverter defibrillator: Two case reports [J].
Deshmukh, P ;
Anderson, K .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (07) :767-772
[5]   MEASUREMENT OF VENTRICULAR ELECTROGRAM AMPLITUDE DURING INTRAOPERATIVE INDUCTION OF VENTRICULAR TACHYARRHYTHMIAS [J].
ELLENBOGEN, KA ;
WOOD, MA ;
STAMBLER, BS ;
WELCH, WJ ;
DAMIANO, RJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (11) :1017-1022
[6]   Detection of ventricular fibrillation by transvenous defibrillating leads: Integrated versus dedicated bipolar sensing [J].
Goldberger, JJ ;
Horvath, G ;
Donovan, D ;
Johnson, D ;
Challapalli, R ;
Kadish, AH .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (07) :677-688
[7]   OVERSENSING DURING VENTRICULAR PACING IN PATIENTS WITH A 3RD-GENERATION IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR [J].
KELLY, PA ;
MANN, DE ;
DAMLE, RS ;
REITER, MJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (07) :1531-1534
[8]   CORRELATION BETWEEN THE VENTRICULAR ELECTROGRAM AMPLITUDE IN SINUS RHYTHM AND IN VENTRICULAR-FIBRILLATION [J].
LEITCH, JW ;
YEE, R ;
KLEIN, GJ ;
JONES, DL ;
MURDOCK, CJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (09) :1105-1109
[9]  
NEUZNER J, 1997, PACE 2, V20, P1225
[10]   Sensing and tachyarrhythmia detection problems in implantable cardioverter defibrillators [J].
Reiter, MJ ;
Mann, DE .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (06) :542-558