Prospective Gating With 320-MDCT Angiography: Effect of Volume Scan Length on Radiation Dose

被引:26
作者
Khan, Atif [1 ,3 ]
Nasir, Khurram [2 ]
Khosa, Faisal [1 ]
Saghir, Amina [1 ]
Sarwar, Sheryar [1 ,4 ]
Clouse, Melvin E. [1 ]
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Boston Univ, Dept Med, Boston Med Ctr, Boston, MA USA
[3] NCI, Bethesda, MD 20892 USA
[4] NHLBI, Bethesda, MD USA
关键词
320-MDCT; cardiac imaging; coronary artery disease; radiation dose reduction; volume scan length; MULTISLICE COMPUTED-TOMOGRAPHY; CORONARY CT ANGIOGRAPHY; DIAGNOSTIC PERFORMANCE; IMAGE QUALITY; CHEST; REDUCTION; EXPOSURE; ARTERIES; PROTOCOL; PRODUCT;
D O I
10.2214/AJR.10.4903
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
OBJECTIVE. The purpose of this study was to evaluate the relation between radiation dose reduction and volume scan length for prospectively ECG-gated 320-MDCT angiography in the diagnosis of coronary artery disease. MATERIALS AND METHODS. MDCT with prospective ECG gating was performed at one of the three volume scan lengths depending on heart length. Of 175 patients, 95 (55%; body mass index, 29 +/- 5.9; mean heart rate, 59 +/- 7 beats/min) underwent scanning at 160 mm; 46 (26%; body mass index, 30 +/- 4.1; mean heart rate, 56 +/- 5.74 beats/min) at 140 mm; and 34 (19%; body mass index, 30 +/- 3.71; mean heart rate, 58 +/- 3.96 beats/min) at 120 mm. RESULTS. The median radiation doses were 6.5 mSv (95% CI, 6.03-7.2 mSv) for the 95 patients who underwent scanning at a volume scan length of 160 mm, 4.33 mSv (95% CI, 4.06-6.62 mSv) for the 46 patients who underwent scanning at 140 mm, and 3.47 mSv (95% CI, 3.15-3.62 mSv) for the 34 patients who underwent scanning at 120 mm. The reduction in scan length from 160 to 140 mm represented a reduction in scan length of 12.5% and the reduction to 120 mm a reduction of 25%. The median radiation dose was reduced 33% when volume scan length was changed to 140 mm and 47% when the length was changed to 120 mm. CONCLUSION. Dose optimization remains an important concern in cardiac CT, and for 320-MDCT angiography, substantial dose reduction can be achieved by reducing volume scan length so that it is in concert with the patient's heart length.
引用
收藏
页码:407 / 411
页数:5
相关论文
共 38 条
[1]
Musings at the beginning of the hyper-CT era [J].
Baker, SR .
ABDOMINAL IMAGING, 2003, 28 (01) :110-114
[2]
Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[3]
Diagnostic Performance of 64-Multidetector Row Coronary Computed Tomographic Angiography for Evaluation of Coronary Artery Stenosis in Individuals Without Known Coronary Artery Disease [J].
Budoff, Matthew J. ;
Dowe, David ;
Jollis, James G. ;
Gitter, Michael ;
Sutherland, John ;
Halamert, Edward ;
Scherer, Markus ;
Bellinger, Raye ;
Martin, Arthur ;
Benton, Robert ;
Delago, Augustin ;
Min, James K. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (21) :1724-1732
[4]
Recent developments in wide-detector cardiac computed tomography [J].
Choi, Sang Il ;
George, Richard T. ;
Schuleri, Karl H. ;
Chun, Eun Ju ;
Lima, Joao A. C. ;
Lardo, Albert C. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 :23-29
[5]
Strategies for formulating appropriate MDCT techniques when imaging the chest, abdomen, and pelvis in pediatric patients [J].
Cody, DD ;
Moxley, DM ;
Krugh, KT ;
O'Daniel, JC ;
Wagner, LK ;
Eftekhari, F .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) :849-859
[6]
Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography [J].
Coles, DR ;
Smail, MA ;
Negus, IS ;
Wilde, P ;
Oberhoff, M ;
Karsch, KR ;
Baumbach, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (09) :1840-1845
[7]
Helical prospective ECG-gating in cardiac computed tomography: radiation dose and image quality [J].
DeFrance, Tony ;
Dubois, Eric ;
Gebow, Dan ;
Ramirez, Alex ;
Wolf, Florian ;
Feuchtner, Gudrun M. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (01) :99-107
[8]
Noninvasive detection of coronary artery stenoses with multislice computed tomography or magnetic resonance imaging [J].
Dewey, Marc ;
Teige, Florian ;
Schnapauff, Dirk ;
Laule, Michael ;
Borges, Adrian C. ;
Wernecke, Klaus-Dieter ;
Schink, Tania ;
Baumann, Gert ;
Rutsch, Wolfgang ;
Rogalla, Patrik ;
Taupitz, Matthias ;
Hamm, Bernd .
ANNALS OF INTERNAL MEDICINE, 2006, 145 (06) :407-415
[9]
Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation [J].
Dewey, Marc ;
Zimmermann, Elke ;
Deissenrieder, Florian ;
Laule, Michael ;
Duebel, Hans-Peter ;
Schlattmann, Peter ;
Knebel, Fabian ;
Rutsch, Wolfgang ;
Hamm, Bernd .
CIRCULATION, 2009, 120 (10) :867-875
[10]
Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose [J].
Earls, James P. ;
Berman, Elise L. ;
Urban, Bruce A. ;
Curry, Charlene A. ;
Lane, Judith L. ;
Jennings, Robert S. ;
McCulloch, Colin C. ;
Hsieh, Jiang ;
Londt, John H. .
RADIOLOGY, 2008, 246 (03) :742-753