Torque-actuated valves for microfluidics

被引:155
作者
Weibel, DB [1 ]
Kruithof, M [1 ]
Potenta, S [1 ]
Sia, SK [1 ]
Lee, A [1 ]
Whitesides, GM [1 ]
机构
[1] Harvard Univ, Dept Chem & Biol Chem, Cambridge, MA 02138 USA
关键词
D O I
10.1021/ac048303p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes torque-actuated valves for controlling the flow of fluids in microfluidic channels. The valves consist of small machine screws (>= 500 mu m) embedded in a layer of polyurethane cast above microfluidic channels fabricated in poly(dimethylsiloxane) (PDMS). The polyurethane is cured photochemically with the screws in place; on curing, it bonds to the surrounding layer of PDMS and forms a stiff layer that retains an impression of the threads of the screws. The valves were separated from the ceiling of microfluidic channels by a layer of PDMS and were integrated into channels using a simple procedure compatible with soft lithography and rapid prototyping. Turning the screws actuated the valves by collapsing the PDMS layer between the valve and channel, controlling the flow of fluids in the underlying channels. These valves have the useful characteristic that they do not require power to retain their setting (on/off). They also allow settings between "on" and "off" and can be integrated into portable, disposable microfluidic devices for carrying out sandwich immunoassays.
引用
收藏
页码:4726 / 4733
页数:8
相关论文
共 54 条
[1]   Hydrophobic valves of plasma deposited octafluorocyclobutane in DRIE channels [J].
Andersson, H ;
van der Wijngaart, W ;
Griss, P ;
Niklaus, F ;
Stemme, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 75 (1-2) :136-141
[2]   Functional hydrogel structures for autonomous flow control inside microfluidic channels [J].
Beebe, DJ ;
Moore, JS ;
Bauer, JM ;
Yu, Q ;
Liu, RH ;
Devadoss, C ;
Jo, BH .
NATURE, 2000, 404 (6778) :588-+
[3]   Physics and applications of microfluidics in biology [J].
Beebe, DJ ;
Mensing, GA ;
Walker, GM .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2002, 4 :261-286
[4]   An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications [J].
Chabinyc, ML ;
Chiu, DT ;
McDonald, JC ;
Stroock, AD ;
Christian, JF ;
Karger, AM ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4491-4498
[5]   Electroosmotically induced hydraulic pumping on microchips: Differential ion transport [J].
Culbertson, CT ;
Ramsey, RS ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2000, 72 (10) :2285-2291
[6]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[7]   Rapid prototyping of microstructures with bell-shaped cross-sections and its application to deformation-based microfluidic valves [J].
Futai, N ;
Gu, W ;
Takayama, S .
ADVANCED MATERIALS, 2004, 16 (15) :1320-+
[8]   Pumping based on transverse electrokinetic effects [J].
Gitlin, I ;
Stroock, AD ;
Whitesides, GM ;
Ajdari, A .
APPLIED PHYSICS LETTERS, 2003, 83 (07) :1486-1488
[9]  
Griss P, 2002, LAB CHIP, V2, P117, DOI [10.1039/b111040n, 10.1039/b11040n]
[10]   Computerized microfluidic cell culture using elastomeric channels and Braille displays [J].
Gu, W ;
Zhu, XY ;
Futai, N ;
Cho, BS ;
Takayama, S .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (45) :15861-15866